510(k) · Cleared
ClearedALLthread Titanium Suture Anchor
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biomet, Inc. · MBI Fastener, Fixation, Nondegradable, Soft Tissue
Cleared on Jan 16, 2020 as substantially equivalent to K042460 (Arthrotek, Inc., 2004) and 1 other predicate after a 90-day review. Its family tree reaches back 5 generations to 1995.
- Decided
- Jan 16, 2020
- Review
- 90 days
- Class
- Class II
- Product code
- MBI
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 5 generations to K943806 (1995). 33 ancestors in all, the oldest K813581 (1982). No later device cites it as a predicate yet.
- Root · 5 generations backK943806 Harpoon Suture AnchorsBiomet, Inc. · 1995
- 4 generations backK012872 Resorbable Screw AnchorArthrotek, Inc. · 2001
- 3 generations backK033355 Lactoscrew Screw AnchorBiomet Orthopedics, Inc. · 2004
- 2 generations backK061389 Allthread Lactosorb Suture AnchorArthrotek, Inc. · 2006
- 1 generation backK080088 Biomet Sports Medicine Anchor Devices and Ziploop ConstructsBiomet Manufacturing, Inc. · 2008 · Recalled
- This deviceK192942 ALLthread Titanium Suture AnchorBiomet, Inc. · 2020
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K943806 | Harpoon Suture Anchors | Biomet, Inc. | 1995 | — |
| −4 | K012872 | Resorbable Screw Anchor | Arthrotek, Inc. | 2001 | — |
| −3 | K033355 | Lactoscrew Screw Anchor | Biomet Orthopedics, Inc. | 2004 | — |
| −2 | K061389 | Allthread Lactosorb Suture Anchor | Arthrotek, Inc. | 2006 | — |
| −1 | K080088 | Biomet Sports Medicine Anchor Devices and Ziploop Constructs | Biomet Manufacturing, Inc. | 2008 | 8 |
| 0 (this device) | K192942 | ALLthread Titanium Suture Anchor | Biomet, Inc. | 2020 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1982 | 1 | 0 |
| 1990 | 1 | 0 |
| 1993 | 1 | 0 |
| 1994 | 2 | 0 |
| 1995 | 1 | 0 |
| 1996 | 4 | 0 |
| 1997 | 2 | 0 |
| 1998 | 3 | 0 |
| 2001 | 4 | 0 |
| 2003 | 1 | 0 |
| 2004 | 3 | 0 |
| 2006 | 4 | 0 |
| 2007 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MBI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MBI device
- #1 K203268 Arthrex FiberTak Suture Anchorscore 21.4 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K042460 | TI - Screw Anchor SPSummary page 4…evice(s): Primary Predicates 510(k) Number Ti - Screw Anchor SP K042460 ALLthread Titanium Anchor K080088 . Purpose and Device The purpos… | 2004 |
| * | K080088 | Biomet Sports Medicine Anchor Devices and Ziploop ConstructsSummary page 4…510(k) Number Ti - Screw Anchor SP K042460 ALLthread Titanium Anchor K080088 . Purpose and Device The purpose of this submission is: Description: To submit a 510(k) fo… | 2008 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 2.6 years on median.
- 6 of the 33 ancestors have a recall of any class.
- 1 other device also cites its predicate K042460.
How does its category compare?
All MBI devicesMBI Fastener, Fixation, Nondegradable, Soft Tissue: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · MBI
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MBI
58in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MBI
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MBI
3,826in 2025
MAUDE reports naming product code MBI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 80 | 24 | 240 |
| 2008 | 10 | 69 | 6 | 338 |
| 2009 | 19 | 82 | 2 | 355 |
| 2010 | 17 | 76 | 3 | 291 |
| 2011 | 30 | 75 | 23 | 328 |
| 2012 | 24 | 94 | 6 | 371 |
| 2013 | 31 | 100 | 2 | 442 |
| 2014 | 23 | 101 | 0 | 504 |
| 2015 | 23 | 85 | 0 | 507 |
| 2016 | 17 | 94 | 0 | 795 |
| 2017 | 17 | 70 | 4 | 675 |
| 2018 | 16 | 91 | 2 | 1,072 |
| 2019 | 31 | 90 | 0 | 1,303 |
| 2020 | 35 | 83 | 1 | 1,454 |
| 2021 | 18 | 107 | 0 | 1,890 |
| 2022 | 19 | 64 | 0 | 1,591 |
| 2023 | 52 | 57 | 1 | 2,503 |
| 2024 | 22 | 30 | 1 | 3,779 |
| 2025 | 27 | 58 | 1 | 3,826 |
| 2026 | 30 | 63 | 0 | — |
What is it indicated for?
The ALLthread™ Titanium Suture Anchor devices are indicated for use in soft tissue reattachment procedures in the shoulder. Specific indications for the shoulder include: Bankart repair, SLAP lesion repair, acromio-clavicular separation, rotator cuff repair, capsule repair or capsulolabral reconstruction, biceps tenodesis, deltoid repair.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K192942 · printed Nov 6, 2026
Cite this page
510(k) Report. “K192942: ALLthread Titanium Suture Anchor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192942
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026