# K193011: CD Horizon™ Fenestrated Screw Set

- Pathway: 510(k) (Traditional)
- Applicant: Medtronic Sofamor Danek USA, Inc.
- Decided: Jan 10, 2020 after 73 days
- Product code: NKB (Thoracolumbosacral Pedicle Screw System)
- Device class: 2
- Regulation: 21 CFR 888.3070
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 19 generations back to K040583 (2004). 178 ancestors in all.
41 later devices descend from it; 3 cite it directly.
0 of 220 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K170347: CD HORIZON™ Fenestrated Screw Set, Medtronic Sofamor Danek USA (2017) Summary page 4.
- K182119: CD HORIZON™ Spinal System, Medtronic Sofamor Danek USA, Inc. (2018) Summary page 4.
- K152604: KYPHON HV-R Fenestrated Screw Cement, CD HORIZON Fenestrated Screw Set, Medtronic Sofamor Danek USA, Incorporated (2016) Summary page 4.
- K191148: Medtronic HV-R™ Bone Cement, Kyphon™ Xpede™ Bone Cement, CD Horizon™ Fenestrated Screw Set, Medtronic Sofamor Danek USA, Inc. (2019) Summary page 4.

## Most influential descendants
- K201362: CD Horizon™ Fenestrated Screw Set, CD Horizon™ Spinal System, Kyphon™ HV-R™ Bone Cement (2020), 38 descendants of its own
- K210637: CD Horizon™ Spinal System (2021), 34 descendants of its own
- K221646: CD HORIZON™ ASTUTE™ SPINAL SYSTEM; CD HORIZON™ Growth Rod Conversion Set; CD HORIZON™ SPINAL SYSTEM; CD Horizon™ Fenestrated Screw Set; COLORADO 2™ SPINAL System; GDLH™ POSTERIOR SPINAL SYSTEM; SHILLA™ Growth Guidance System; TENOR™ SPINAL SYSTEM (2022), 20 descendants of its own
- K221244: CD Horizon™ Spinal System (2022), 20 descendants of its own
- K223494: CD Horizon Spinal System (2023), 17 descendants of its own

## Indications for use
When used without cement, CD Horizon™ Fenestrated Screws (with or without Sextant™ or Longitude™ instrumentation) are intended for posterior, non-cervical fixation as an adjunct to fusion for the following indications: degenerative disc disease (DDD - defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, tumor and/or trauma (e.g. fracture or dislocation), spinal stenosis, curvatures (e.g. scoliosis, kyphosis, or lordosis), pseudarthrosis, and/or failed previous fusion. Additionally, CD Horizon™ Fenestrated Screws may be used for immobilization and stabilization when used for trauma (e.g., fracture or dislocation) with the usage of bone graft material left to the surgeon’s discretion. When used in conjunction with Medtronic HV-R™ Fenestrated Screw Cement or Kyphon™ Xpede™ Bone Cement, CD Horizon™ Fenestrated Screws are intended to restore the integrity of the spinal column even in the absence of fusion for a limited time in patients with advanced stage tumors involving the thoracic, lumbar, or sacral spine in whom life expectancy is of insufficient duration to permit achievement of fusion. CD Horizon™ Fenestrated Screws augmented with Medtronic HV-R™ Fenestrated Screw Cement or Kyphon™ Xpede™ Bone Cement are for use at spinal levels where the structural integrity of the spine is not severely compromised.

Source page: https://510kreport.com/device/K193011