Avenir Muller Stem, Avenir Cemented Hip Stem

K193030510(k) SpecialCleared Dec 6, 201937-day reviewClass II21 CFR 888.3353

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Zimmer GmbH · LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

Cleared on Dec 6, 2019 as substantially equivalent to K123392 (Zimmer GmbH, 2013) after a 37-day review. Its family tree reaches back 7 generations to 1994. 3 later devices descend from it.

Decided
Dec 6, 2019
Review
37 days
Class
Class II
Product code
LZO
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K935452 (1994). 61 ancestors in all, the oldest K845025 (1985). 3 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2008: 1 other ancestor2006: 1 other ancestor2003: 3 other ancestors1996: 8 other ancestors2004: 2 other ancestors2002: 2 other ancestors2000: 6 other ancestors1997: 2 other ancestors1994: 7 other ancestors2001: 2 other ancestors1999: 3 other ancestors1998: 2 other ancestors1993: 1 other ancestor1990: 1 other ancestor1987: 2 other ancestors1985: 3 other ancestors1995: 2 other ancestors1992: 2 other ancestors1991: 2 other ancestors1988: 2 other ancestors2020: 1 descendant cleared2024: 1 descendant cleared2026: 1 descendant clearedReference device: K131884 · Avenir Cemented Hip Stem · Zimmer GmbH · 2013Reference device: K182048 · Avenir Complete Hip System · Zimmer, Inc. · 2018K935452 · P.F.C. 2 Total Hip System Porous Coated Modular Femoral Component · Johnson & Johnson Orthopaedics, Inc. · 1994×2: 2 generations cleared close together, K945518 (1996), K961939 (1996) K974331 · Uni-Rom Total Hip System Femoral Stem · Johnson & Johnson Professionals, Inc. · 1998K001991 · Titan Porocoat Hip Prosthesis · DePuy Orthopaedics, Inc. · 2000K042992 · Corail Amt Hip Prosthesis · DePuy Orthopaedics, Inc. · 2005 · recalledK123392 · Avenir Muller Stem · Zimmer GmbH · 2013 · recalled1990200020102020
  1. Root · 7 generations backK935452 P.F.C. 2 Total Hip System Porous Coated Modular Femoral ComponentJohnson & Johnson Orthopaedics, Inc. · 1994
  2. 6 generations backK945518 P.F.C. 2 Total Hip System Porous Coated Modular Femoral ComponentJohnson & Johnson Professionals, Inc. · 1996
  3. 5 generations backK961939 S-Rom Femoral Hip Stem (Sizes 12 X 06 X 115 and 12 X 07 X 115)Johnson & Johnson Professionals, Inc. · 1996
  4. 4 generations backK974331 Uni-Rom Total Hip System Femoral StemJohnson & Johnson Professionals, Inc. · 1998
  5. 3 generations backK001991 Titan Porocoat Hip ProsthesisDePuy Orthopaedics, Inc. · 2000
  6. 2 generations backK042992 Corail Amt Hip ProsthesisDePuy Orthopaedics, Inc. · 2005 · Recalled
  7. 1 generation backK123392 Avenir Muller StemZimmer GmbH · 2013 · Recalled
  8. This deviceK193030 Avenir Muller Stem, Avenir Cemented Hip StemZimmer GmbH · 2019
  9. Descendant · cites it directly · 0 of its ownK260182 Avenir® Müller Stem; Avenir Complete™ Hip SystemZimmer, Inc. · 2026
  10. Descendant · cites it directly · 0 of its ownK241241 Z1 Cemented Hip SystemOrchard Medical Development, LLC · 2024
  11. Descendant · cites it directly · 0 of its ownK200112 Zimmer Hip Joint ReplacementZimmer GmbH · 2020 · Recalled

Most influential descendants

Showing 3 of 3 · See all
  • K260182Avenir® Müller Stem; Avenir Complete™ Hip SystemZimmer, Inc. · 2026 · cites it directly0descendants
  • K241241Z1 Cemented Hip SystemOrchard Medical Development, LLC · 2024 · cites it directly0descendants
  • K200112Zimmer Hip Joint ReplacementZimmer GmbH · 2020 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K935452P.F.C. 2 Total Hip System Porous Coated Modular Femoral ComponentJohnson & Johnson Orthopaedics, Inc.1994—
−6K945518P.F.C. 2 Total Hip System Porous Coated Modular Femoral ComponentJohnson & Johnson Professionals, Inc.1996—
−5K961939S-Rom Femoral Hip Stem (Sizes 12 X 06 X 115 and 12 X 07 X 115)Johnson & Johnson Professionals, Inc.1996—
−4K974331Uni-Rom Total Hip System Femoral StemJohnson & Johnson Professionals, Inc.1998—
−3K001991Titan Porocoat Hip ProsthesisDePuy Orthopaedics, Inc.2000—
−2K042992Corail Amt Hip ProsthesisDePuy Orthopaedics, Inc.20051
−1K123392Avenir Muller StemZimmer GmbH20134
0 (this device)K193030Avenir Muller Stem, Avenir Cemented Hip StemZimmer GmbH2019—
+1K260182Avenir® Müller Stem; Avenir Complete™ Hip SystemZimmer, Inc.2026—
+1K241241Z1 Cemented Hip SystemOrchard Medical Development, LLC2024—
+1K200112Zimmer Hip Joint ReplacementZimmer GmbH20202

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198530
198720
198820
199010
199120
199220
199310
199470
199520
199680
199720
199820
199930
200060
200120
200220
200330
200420
200610
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
202410
202610
FIG. 1 — Lineage of K193030, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZO device

  1. #1 K192827 Quadra-Pscore 19.3 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K123392Avenir Muller Stem
Summary page 5
…hip) metallic cemented or uncemented prosthesis. Primary Predicate Device: Avenir® Müller Stem, manufactured by Zimmer GmbH, K123392, cleared March 2013…
Zimmer GmbH20134
†K131884Avenir Cemented Hip StemZimmer GmbH2013—
†K182048Avenir Complete Hip SystemZimmer, Inc.2018—

Also cleared against K123392: 5 other devices →

What descends from it? (3)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K260182Avenir® Müller Stem; Avenir Complete™ Hip SystemZimmer, Inc.20260
K241241Z1 Cemented Hip SystemOrchard Medical Development, LLC20240
K200112Zimmer Hip Joint ReplacementZimmer GmbH20200

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 2.5 years on median.
  • 14 of the 61 ancestors have a recall of any class.
  • Of its descendants, K260182 (Zimmer, Inc., 2026) has gone furthest, with 0 descendants of its own.
  • 5 other devices also cite its predicate K123392.

How does its category compare?

All LZO devices

LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · LZO

14in 2025

2007: 92008: 112009: 72010: 152011: 132012: 142013: 262014: 132015: 122016: 102017: 162018: 182019: 282020: 182021: 122022: 112023: 102024: 112025: 142026 (partial year): 9
2007high 28 (2019) · low 7 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZO

119in 2025

2007: 87 days median2008: 63 days median2009: 83 days median2010: 78 days median2011: 87 days median2012: 98 days median2013: 100 days median2014: 85 days median2015: 115 days median2016: 177 days median2017: 257 days median2018: 163 days median2019: 109 days median2020: 112 days median2021: 170 days median2022: 279 days median2023: 122 days median2024: 111 days median2025: 119 days median2026 (partial year): 102 days median
2007high 279 (2022) · low 63 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZO

1in 2025

2007: 22008: 132009: 422011: 102012: 142014: 12015: 12016: 92017: 52018: 22019: 42020: 32022: 42023: 22024: 12025: 1
2007high 42 (2009) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZO

3,244in 2025

2007: 1382008: 1252009: 1892010: 3942011: 5442012: 9632013: 1,3702014: 1,4772015: 1,3482016: 1,7282017: 2,1652018: 3,1332019: 3,0662020: 1,9632021: 2,1992022: 1,9852023: 2,0662024: 2,5862025: 3,244
2007high 3,244 (2025) · low 125 (2008)2025

MAUDE reports naming product code LZO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20079872138
2008116313125
200978342189
201015780394
2011138710544
2012149814963
20132610001,370
2014138511,477
20151211511,348
20161017791,728
20171625752,165
20181816323,133
20192810943,066
20201811231,963
20211217002,199
20221127941,985
20231012222,066
20241111112,586
20251411913,244
202691020—

What is it indicated for?

• Advanced wear of the joint due to degenerative, post-traumatic or rheumatic diseases. • Failed previous hip surgery (not THA) where pain, deformity, or dysfunction persists. • Optional use in revision: in some medical conditions (e.g., early revision when healthy and good bone stock exists), the surgeon may opt to use primary implants in a revision procedure. • Acute traumatic fracture of the femoral head or neck. • Avascular necrosis of the femoral…

Read the full statement (149 words)

• Advanced wear of the joint due to degenerative, post-traumatic or rheumatic diseases.

• Failed previous hip surgery (not THA) where pain, deformity, or dysfunction persists.

• Optional use in revision: in some medical conditions (e.g., early revision when healthy and good bone stock exists), the surgeon may opt to use primary implants in a revision procedure.

• Acute traumatic fracture of the femoral head or neck.

• Avascular necrosis of the femoral head.

Avenir® Müller Stems are for cementless use only.

The product is intended for total or hemi hip arthroplasty with cemented applications for rehabilitating hips damaged as a result of:

• Advanced wear of the joint due to degenerative, post-traumatic, or rheumatic diseases

• Failed previous hip surgery including joint reconstruction (osteotomy), arthrodesis, hemiarthroplasty or total hip replacement (THR)

• Acute traumatic fracture of the femoral head or neck

• Avascular necrosis of the femoral head.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K193030: Avenir Muller Stem, Avenir Cemented Hip Stem.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K193030

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026