510(k) Report

510(k) · Cleared

Cleared

LIAISON Lyme Total Antibody Plus, LIAISON Lyme Total Antibody Plus Control Set

K193051510(k) TraditionalCleared Jan 29, 202089-day reviewClass II21 CFR 866.3830

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

DiaSorin, Inc. · LSR Reagent, Borrelia Serological Reagent

Cleared on Jan 29, 2020 as substantially equivalent to K113397 (Zeus Scientific, Inc., 2012) after an 89-day review. Its family tree reaches back 1 generation to 2012.

Decided
Jan 29, 2020
Review
89 days
Class
Class II
Product code
LSR
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K113397 (2012). No later device cites it as a predicate yet.

K113397 · Zeus Elisa Borrelia Vlse-1/PEPC10 Igg/Igm Test System · Zeus Scientific, Inc. · 20122010201220142016201820202022
  1. Root · 1 generation backK113397 Zeus Elisa Borrelia Vlse-1/PEPC10 Igg/Igm Test SystemZeus Scientific, Inc. · 2012
  2. This deviceK193051 LIAISON Lyme Total Antibody Plus, LIAISON Lyme Total Antibody Plus…DiaSorin, Inc. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K113397Zeus Elisa Borrelia Vlse-1/PEPC10 Igg/Igm Test SystemZeus Scientific, Inc.2012—
0 (this device)K193051LIAISON Lyme Total Antibody Plus, LIAISON Lyme Total Antibody Plus Control SetDiaSorin, Inc.2020—
FIG. 1 — Lineage of K193051, 2012–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LSR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LSR device

  1. #1 K254295 Sofia Lyme FIA; Sofia 2 Campylobacter FIAscore 12.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K113397Zeus Elisa Borrelia Vlse-1/PEPC10 Igg/Igm Test System
Summary page 3
…LSR Predicate Device: Zeus ELISA Borrelia VlsE1/pepC10 IgG/IgM Test System (K113397) INTENDED USE: LIAISON® Lyme Total Antibody Plus: The LIAISON® Lyme Total Antibody Plus assay uses chemiluminescent immunoas…
Zeus Scientific, Inc.2012—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All LSR devices

LSR Reagent, Borrelia Serological Reagent: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · LSR

2in 2025

2007: 12008: 22009: 22010: 12012: 32013: 22015: 12016: 12017: 62018: 32019: 42020: 32021: 62022: 12023: 12024: 12025: 22026 (partial year): 1
2007high 6 (2017) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LSR

133in 2021

2012: 155 days median2017: 150 days median2018: 92 days median2019: 86 days median2020: 91 days median2021: 133 days median
2007high 155 (2012) · low 86 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LSR

1in 2025

2013: 12021: 22025: 1
2007high 2 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LSR

1in 2025

2008: 22011: 12014: 532015: 252016: 102017: 92018: 42019: 152020: 72021: 42022: 12023: 22025: 1
2007high 53 (2014) · low 0 (2007)2025

MAUDE reports naming product code LSR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20082—02
20092—00
20101—00
20110—01
2012315500
20132—10
20140—053
20151—025
20161—010
2017615009
201839204
2019486015
202039107
2021613324
20221—01
20231—02
20241—00
20252—11
20261—0—

What is it indicated for?

LIAISON® Lyme Total Antibody Plus: The LIAISON® Lyme Total Antibody Plus assay uses chemiluminescent immunoassay (CLIA) technology for the qualitative determination of lgG and IgM antibodies to Borrelia burgdorferi in human serum and plasma (K2-EDTA, Li-heparin) samples. This assay is intended for use on samples from patients with signs and symptoms that are consistent with Lyme disease. Positive or equivocal results should be supplemented by testing…

Read the full statement (186 words)

LIAISON® Lyme Total Antibody Plus: The LIAISON® Lyme Total Antibody Plus assay uses chemiluminescent immunoassay (CLIA) technology for the qualitative determination of lgG and IgM antibodies to Borrelia burgdorferi in human serum and plasma (K2-EDTA, Li-heparin) samples. This assay is intended for use on samples from patients with signs and symptoms that are consistent with Lyme disease. Positive or equivocal results should be supplemented by testing with a standardized Western blot procedure. Positive supplemental results provide evidence of exposure to B. burgdorferi and can be used to support a clinical diagnosis of Lyme disease. Negative results by LIAISON® Lyme Total Antibody Plus assay should not be used to exclude Lyme disease. The test has to be performed on the LIAISON® XL Analyzer.

The LIAISON® Lyme Total Antibody Plus Control Set: The LIAISON® Lyme Total Antibody Plus Control Set is intended for use as assayed quality control samples to monitor the performance of the LIAISON® Lyme Total Antibody Plus assay. The performance characteristics of LIAISON® Lyme Total Antibody Plus Control Set have not been established for any other assays or instrument platforms different from the LIAISON® XL.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K193051: LIAISON Lyme Total Antibody Plus, LIAISON Lyme Total Antibody Plus Control Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K193051

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026