510(k) · Cleared
ClearedGoChek Blood Glucose Monitoring System, GoChek Connect Blood Glucose Monitoring System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Microtech Medical, Inc. · NBW System, Test, Blood Glucose, Over The Counter
Cleared on Sep 11, 2020 as substantially equivalent to K130284 (ACON Laboratories, Inc., 2013) after a 284-day review. Its family tree reaches back 3 generations to 2000.
- Decided
- Sep 11, 2020
- Review
- 284 days
- Class
- Class II
- Product code
- NBW
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K002134 (2000). No later device cites it as a predicate yet.
- Root · 3 generations backK002134 One Touch Ultra Blood Glucose Monitoring SystemSelfcare, Inc. · 2000
- 2 generations backK112653 ON Call Vivid Blood Glucose Monitoring SystemsACON Laboratories, Inc. · 2012
- 1 generation backK130284 ON Call Sharp Blood Glucose Monitoring SystemACON Laboratories, Inc. · 2013
- This deviceK193340 GoChek Blood Glucose Monitoring System, GoChek Connect Blood Glucose…Microtech Medical, Inc. · 2020
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K002134 | One Touch Ultra Blood Glucose Monitoring System | Selfcare, Inc. | 2000 | — |
| −2 | K112653 | ON Call Vivid Blood Glucose Monitoring Systems | ACON Laboratories, Inc. | 2012 | — |
| −1 | K130284 | ON Call Sharp Blood Glucose Monitoring System | ACON Laboratories, Inc. | 2013 | — |
| 0 (this device) | K193340 | GoChek Blood Glucose Monitoring System, GoChek Connect Blood Glucose… | Microtech Medical, Inc. | 2020 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NBW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NBW device
- #1 K260545 CONTOUR® PLUS BLUE Blood Glucose Monitoring…score 14.6 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K130284 | ON Call Sharp Blood Glucose Monitoring SystemSummary page 6…number: 862.1345 Glucose Test System 7. Predicate device On Call Sharp Blood Glucose Monitoring System ACON Laboratories, Inc. 510(k) number: k130284 8. Device information Microtech Medical, Inc. GoChek page 3/15… | 2013 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 6.7 years on median.
- None of the 3 ancestors has a recall.
- 1 other device also cites its predicate K130284.
How does its category compare?
All NBW devicesNBW System, Test, Blood Glucose, Over The Counter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · NBW
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NBW
243in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NBW
1in 2025
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · NBW
4,745in 2025
MAUDE reports naming product code NBW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 29 | 85 | 9 | 7,991 |
| 2008 | 37 | 128 | 2 | 7,704 |
| 2009 | 38 | 140 | 5 | 10,963 |
| 2010 | 31 | 132 | 11 | 11,631 |
| 2011 | 30 | 328 | 1 | 22,909 |
| 2012 | 30 | 230 | 1 | 23,449 |
| 2013 | 47 | 167 | 5 (2) | 35,408 |
| 2014 | 24 | 202 | 1 | 38,524 |
| 2015 | 32 | 237 | 0 | 62,111 |
| 2016 | 20 | 233 | 1 | 76,621 |
| 2017 | 25 | 244 | 0 | 37,538 |
| 2018 | 19 | 168 | 0 | 16,911 |
| 2019 | 10 | 127 | 14 | 14,472 |
| 2020 | 7 | 121 | 0 | 10,703 |
| 2021 | 7 | 465 | 0 | 9,198 |
| 2022 | 12 | 410 | 0 | 8,103 |
| 2023 | 5 | 193 | 0 | 7,256 |
| 2024 | 7 | 243 | 0 | 6,220 |
| 2025 | 2 | — | 1 | 4,745 |
| 2026 | 5 | 190 | 0 | — |
What is it indicated for?
GoChek Blood Glucose Monitoring System The GoChek Blood Glucose Monitoring System comprises of the GoChek Blood Glucose Meter and GoChek Blood Glucose Test Strips. The GoChek Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose in fresh capillary whole blood from the fingertips. The GoChek Blood Glucose Monitoring System is intended for self-testing by people with diabetes at home as an aid in monitoring the…
Read the full statement (250 words)
GoChek Blood Glucose Monitoring System
The GoChek Blood Glucose Monitoring System comprises of the GoChek Blood Glucose Meter and GoChek Blood Glucose Test Strips. The GoChek Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose in fresh capillary whole blood from the fingertips. The GoChek Blood Glucose Monitoring System is intended for self-testing by people with diabetes at home as an aid in monitoring the effectiveness of diabetes control programs. The GoChek Blood Glucose Monitoring System is intended for single-patient use and should not be shared.
The GoChek Blood Glucose Monitoring System is for in vitro diagnostic use. The GoChek Blood Glucose Monitoring System is not intended for the diagnosis of or screening for diabetes.
GoChek Connect Blood Glucose Monitoring System
The GoChek Connect Blood Glucose Monitoring System comprises of the GoChek Connect Blood Glucose Meter and GoChek Blood Glucose Test Strips. The GoChek Connect Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose in fresh capillary whole blood from the fingertips. The GoChek Connect Blood Glucose Monitoring System is intended for self-testing by people with diabetes at home as an aid in monitoring the effectiveness of diabetes control programs. The GoChek Connect Blood Glucose Monitoring System is intended for single-patient use and should not be shared.
The GoChek Connect Blood Glucose Monitoring System is for in vitro diagnostic use. The GoChek Connect Blood Glucose Monitoring System is not intended for the diagnosis of or screening for diabetes.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K193340 · printed Nov 6, 2026
Cite this page
510(k) Report. “K193340: GoChek Blood Glucose Monitoring System, GoChek Connect Blood Glucose Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K193340
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026