510(k) Report

510(k) · Cleared

Cleared

EBERLE Shaver System C3 and Accessories

K193608510(k) TraditionalCleared Jan 15, 2021386-day reviewClass II21 CFR 888.1100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Eberle GmbH & Co. KG · HRX Arthroscope

Cleared on Jan 15, 2021 as substantially equivalent to K092977 (Efs Eberle Feinwerktechnische Systeme, 2010) after a 386-day review. Its family tree reaches back 7 generations to 1993.

Decided
Jan 15, 2021
Review
386 days
Class
Class II
Product code
HRX
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K931783 (1993). 40 ancestors in all, the oldest K771218 (1978). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2007: 1 other ancestor2006: 4 other ancestors2003: 1 other ancestor2000: 1 other ancestor1999: 1 other ancestor2001: 1 other ancestor1998: 3 other ancestors1997: 3 other ancestors1995: 6 other ancestors1994: 6 other ancestors1986: 2 other ancestors1978: 1 other ancestor1996: 2 other ancestors1985: 1 other ancestorK931783 · Aesop (Automated Endoscopic System for Optimal Pos · Computer Motion, Inc. · 1993K960655 · Aesop System and Accessories · Computer Motion, Inc. · 1996×2: 2 generations cleared close together, K973700 (1998), K980787 (1998) K991696 · Stryker Hermes-Ready Total Performance System · Stryker Instruments · 1999K032117 · Stryker Total Performance (TPS) System · Stryker Instruments · 2003K092977 · Eberle Shaver System Accessories · Efs Eberle Feinwerktechnische Systeme · 201019801990200020102020
  1. Root · 7 generations backK931783 Aesop (Automated Endoscopic System for Optimal PosComputer Motion, Inc. · 1993
  2. 6 generations backK960655 Aesop System and AccessoriesComputer Motion, Inc. · 1996
  3. 5 generations backK973700 Hermes Operating Room Control CenterComputer Motion, Inc. · 1998
  4. 4 generations backK980787 Hermes Operating Room Control Center with the Wom 20L InsufflatorComputer Motion, Inc. · 1998
  5. 3 generations backK991696 Stryker Hermes-Ready Total Performance SystemStryker Instruments · 1999
  6. 2 generations backK032117 Stryker Total Performance (TPS) SystemStryker Instruments · 2003
  7. 1 generation backK092977 Eberle Shaver System AccessoriesEfs Eberle Feinwerktechnische Systeme · 2010
  8. This deviceK193608 EBERLE Shaver System C3 and AccessoriesEberle GmbH & Co. KG · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K931783Aesop (Automated Endoscopic System for Optimal PosComputer Motion, Inc.1993—
−6K960655Aesop System and AccessoriesComputer Motion, Inc.1996—
−5K973700Hermes Operating Room Control CenterComputer Motion, Inc.1998—
−4K980787Hermes Operating Room Control Center with the Wom 20L InsufflatorComputer Motion, Inc.1998—
−3K991696Stryker Hermes-Ready Total Performance SystemStryker Instruments1999—
−2K032117Stryker Total Performance (TPS) SystemStryker Instruments2003—
−1K092977Eberle Shaver System AccessoriesEfs Eberle Feinwerktechnische Systeme2010—
0 (this device)K193608EBERLE Shaver System C3 and AccessoriesEberle GmbH & Co. KG2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197810
198510
198620
199460
199560
199620
199730
199830
199910
200010
200110
200310
200640
200710
FIG. 1 — Lineage of K193608, 1993–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HRX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HRX device

  1. #1 K260203 Fule Vertebroplasty Balloon Catheterscore 14.9 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K092977Eberle Shaver System Accessories
Summary page 6
…usively as a system. EBERLE Shaver System C2 and C3 use the same shaver blades. The shaver blades are identical with the once already cleared under the predicated device K092977 - Eberle Shaver System Accessories. Eberle has added addition blades to provide a broader offering. EBERLE Shaver System C2 and…
Efs Eberle Feinwerktechnische Systeme2010—
*—EBERLE Shaver System C2 and Shaver Blades
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 4 companies; a new generation was cleared every 2.4 years on median.
  • 6 of the 40 ancestors have a recall of any class.

How does its category compare?

All HRX devices

HRX Arthroscope: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · HRX

9in 2025

2007: 72008: 92009: 112010: 92011: 32012: 112013: 122014: 92015: 42016: 82017: 42018: 122019: 122020: 72021: 72022: 32023: 42024: 62025: 92026 (partial year): 7
2007high 12 (2013) · low 3 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HRX

107in 2025

2007: 89 days median2008: 115 days median2009: 139 days median2010: 114 days median2011: 84 days median2012: 102 days median2013: 90 days median2014: 140 days median2015: 132 days median2016: 89 days median2017: 97 days median2018: 101 days median2019: 45 days median2020: 141 days median2021: 57 days median2022: 89 days median2023: 249 days median2024: 110 days median2025: 107 days median2026 (partial year): 217 days median
2007high 249 (2023) · low 45 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HRX

1in 2024

2007: 32008: 132009: 232010: 122011: 62013: 42015: 72018: 12021: 32024: 1
2007high 23 (2009) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HRX

2,076in 2025

2007: 4212008: 4412009: 5582010: 6122011: 6312012: 7782013: 6782014: 8022015: 7632016: 4692017: 9342018: 1,5812019: 1,6762020: 1,7062021: 1,9082022: 1,4062023: 1,8522024: 2,4272025: 2,076
2007high 2,427 (2024) · low 421 (2007)2025

MAUDE reports naming product code HRX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20077893421
2008911513441
20091113923558
2010911412612
20113846631
2012111020778
201312904678
201491400802
201541327763
20168890469
20174970934
20181210111,581
2019124501,676
2020714101,706
202175731,908
202238901,406
2023424901,852
2024611012,427
2025910702,076
202672170—

What is it indicated for?

The EBERLE shaver system C3 is a powered instrument system and consists of a control unit, a footswitch, a handpiece and accessories. It is designed for arthroscopy surgical procedures like shaving, burring, abrading, cutting and resecting of fibrous tissue, cartilage tissue and bone.

The EBERLE shaver system accessories are designed to use with the EBERLE shaver system for arthroscopy surgical procedures like shaving, burring, abrading, cutting, drilling and resecting of fibrous tissue, cartilage tissue and bone.”

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K193608: EBERLE Shaver System C3 and Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K193608

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026