510(k) Report

510(k) · Cleared

Cleared

Non-Sterile, Powder Free Nitrile Examination Gloves, Low Dermatitis Potential, and Tested for Use with Chemotherapy Drugs Blue-AC

K200453510(k) TraditionalCleared May 1, 202067-day reviewClass I21 CFR 880.6250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Yty Industry (Manjung) Sdn Bhd · LZA Polymer Patient Examination Glove

Cleared on May 1, 2020 after a 67-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
May 1, 2020
Review
67 days
Class
Class I
Product code
LZA
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K200453Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZA device

  1. #1 K192333 Blue Nitrile Examination Gloves Powder Freescore 71.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All LZA devices

LZA Polymer Patient Examination Glove: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · LZA

24in 2025

2007: 212008: 182009: 282010: 312011: 262012: 332013: 202014: 272015: 202016: 302017: 442018: 222019: 252020: 302021: 1392022: 1462023: 622024: 302025: 242026 (partial year): 15
2007high 146 (2022) · low 18 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZA

110in 2025

2007: 95 days median2008: 97 days median2009: 112 days median2010: 97 days median2011: 122 days median2012: 110 days median2013: 130 days median2014: 197 days median2015: 112 days median2016: 171 days median2017: 124 days median2018: 178 days median2019: 212 days median2020: 101 days median2021: 111 days median2022: 111 days median2023: 92 days median2024: 89 days median2025: 110 days median2026 (partial year): 103 days median
2007high 212 (2019) · low 89 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZA

3so far in 2026, the most since 2007

2015: 12016: 12026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZA

73in 2025

2007: 72008: 22009: 122010: 122011: 92012: 112013: 102014: 82015: 122016: 252017: 42018: 32019: 212020: 42021: 202022: 192023: 242024: 762025: 73
2007high 76 (2024) · low 2 (2008)2025

MAUDE reports naming product code LZA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007219507
2008189702
200928112012
20103197012
20112612209
201233110011
201320130010
20142719708
201520112112
201630171125
20174412404
20182217803
201925212021
20203010104
2021139111020
2022146111019
20236292024
20243089076
202524110073
2026151033—

What is it indicated for?

A patient examination glove is a disposable device intended for medical purpose that is worn on the examiner’s hand or finger to prevent contamination between patient and examiner. In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs: Blue Tested Chemotherapy Drug And Concentration Average Breakthrough…

Read the full statement (470 words)

A patient examination glove is a disposable device intended for medical purpose that is worn on the examiner’s hand or finger to prevent contamination between patient and examiner.

In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs:

Blue

Tested Chemotherapy Drug And Concentration Average Breakthrough Detection Time (minutes)

Carboplatin, 10 mg/ml > 240 minutes

Carmustine, 3.3 mg/ml 11.3 minutes

Cisplatin (BCNU), 1.0 mg/ml > 240 minutes

Cyclophosphamide (Cytoxan), 20.0 mg/ml > 240 minutes

Dacarbazine (DTIC), 10.0 mg/ml > 240 minutes

Doxorubicin Hydrochloride, 2.0 mg/ml > 240 minutes

Etoposide (Toposar), 20.0 mg/ml > 240 minutes

Fluorouracil, 50.0 mg/ml > 240 minutes

Ifosfamide, 50.0 mg/ml > 240 minutes

Methotrexate, 25 mg/ml > 240 minutes

Mitomycin C, 0.5 mg/ml > 240 minutes

Mitoxantrone, 2 mg/ml > 240 minutes

Paclitaxel (Taxol), 6.0 mg/ml > 240 minutes

ThioTEPA, 10.0 mg/ml 7.4 minutes

Vincristine Sulfate, 1.0 mg/ml > 240 minutes

The following chemotherapy drugs and concentration have extremely low permeation time.

Carmustine (3.3 mg/ml): 11.3 minutes ThioTEPA (10.0 mg/ml): 7.4 minutes

WARNING: NOT TO BE USED WITH CARMUSTINE OR THIOTEPA

A patient examination glove is a disposable device intended for medical purpose that is worn on the examiner’s hand or finger to prevent contamination between patient and examiner.

In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs and Fentanyl Citrate:

Blue

Tested Chemotherapy Drug And Concentration Average Breakthrough Detection Time (minutes)

Carboplatin, 10 mg/ml > 240 minutes

Carmustine, 3.3 mg/ml 30.3 minutes

Cisplatin (BCNU), 1.0 mg/ml > 240 minutes

Cyclophosphamide (Cytoxan), 20.0 mg/ml > 240 minutes

Dacarbazine (DTIC), 10.0 mg/ml > 240 minutes

Doxorubicin Hydrochloride, 2.0 mg/ml > 240 minutes

Etoposide (Toposar), 20.0 mg/ml > 240 minutes

Fluorouracil, 50.0 mg/ml > 240 minutes

Ifosfamide, 50.0 mg/ml > 240 minutes

Methotrexate, 25 mg/ml > 240 minutes

Mitomycin C, 0.5 mg/ml > 240 minutes

Mitoxantrone, 2 mg/ml > 240 minutes

Paclitaxel (Taxol), 6.0 mg/ml > 240 minutes

ThioTEPA, 10.0 mg/ml 91.0 minutes

Vincristine Sulfate, 1.0 mg/ml > 240 minutes

Busulfan, 6 mg/ml > 240 minutes

Cytarabine, 100 mg/ml > 240 minutes

Daunorubicin, 5 mg/ml > 240 minutes

Docetaxel, 10 mg/ml > 240 minutes

Epirubicin, 2 mg/ml > 240 minutes

Gemcitabine, 38 mg/ml > 240 minutes

Irinotecan Hydrochloride, 20 mg/ml > 240 minutes

Mechlorethamine HCL, 1.0 mg/ml > 240 minutes

Melphalan, 5 mg/ml > 240 minutes

Trisenox, 0.1 mg/ml > 240 minutes

Fentanyl Citrate, 100mcg/2ml > 240 minutes

The following chemotherapy drugs and concentration have extremely low permeation time.

Carmustine (3.3 mg/ml): 30.3 minutes ThioTEPA (10.0 mg/ml): 91.0 minutes

CAUTION: CARMUSTINE (3.3 MG/ML) AND THIOTEPA (10 MG/ML) HAVE MUCH LOWER PERMEATION TIMES COMPARE TO OTHER CHEMOTHERAPY DRUGS

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K200453: Non-Sterile, Powder Free Nitrile Examination Gloves, Low Dermatitis Potential, and Tested for Use with Chemotherapy Drugs Blue-AC.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K200453

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026