510(k) Report

510(k) · Cleared

Cleared

EON Portable RO Water Purification System

K200670510(k) SpecialCleared Apr 16, 202034-day reviewClass II21 CFR 876.5665

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mar Cor Purification, Inc. · FIP Subsystem, Water Purification

Cleared on Apr 16, 2020 as substantially equivalent to K171099 (Cantel, 2018) and 1 other predicate after a 34-day review. Its family tree reaches back 5 generations to 1981.

Decided
Apr 16, 2020
Review
34 days
Class
Class II
Product code
FIP
Recalls
None
Predicates
2

Its longest line of descent runs back 5 generations to K811678 (1981). 7 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backK811678 Gambro Water Purification Monitor WRDGambro, Inc. · 1981
  2. 4 generations backK042797 Wro 300 Water Purification System for HemodialysisGambro Renal Products · 2005
  3. 3 generations backK093608 Gambro Water Purification Unit, Models Wro 300 and Wro 300 HGambro Renal Products, Inc. · 2010
  4. 2 generations backK110578 Millenium HX Portable Reverse Osmosis Water Purification SystemMar Cor Purification, Inc. · 2011 · Recalled
  5. 1 generation backK171099 EON Portable Reverse Osmosis Water Purification SystemCantel · 2018
  6. This deviceK200670 EON Portable RO Water Purification SystemMar Cor Purification, Inc. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K811678Gambro Water Purification Monitor WRDGambro, Inc.1981—
−4K042797Wro 300 Water Purification System for HemodialysisGambro Renal Products2005—
−3K093608Gambro Water Purification Unit, Models Wro 300 and Wro 300 HGambro Renal Products, Inc.2010—
−2K110578Millenium HX Portable Reverse Osmosis Water Purification SystemMar Cor Purification, Inc.20111
−1K171099EON Portable Reverse Osmosis Water Purification SystemCantel2018—
0 (this device)K200670EON Portable RO Water Purification SystemMar Cor Purification, Inc.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
200110
FIG. 1 — Lineage of K200670, 1981–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FIP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FIP device

  1. #1 K251851 DIASAFEplusUS (F00013010)score 14.0 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K171099EON Portable Reverse Osmosis Water Purification System
Summary page 4
…substantial equivalence of the EON Portable Reverse Osmosis Water Purification System to its predicates – EON Portable Reverse Osmosis Water Purification System, 510(k) K171099 and WRO 300H, 510(k) K093608 – both currently cleared for sale in the U.S. 1. Device Description The device is a portable wat…
Cantel2018—
*K093608Gambro Water Purification Unit, Models Wro 300 and Wro 300 H
Summary page 4
…he EON Portable Reverse Osmosis Water Purification System to its predicates – EON Portable Reverse Osmosis Water Purification System, 510(k) K171099 and WRO 300H, 510(k) K093608 – both currently cleared for sale in the U.S. 1. Device Description The device is a portable water purification system which…
Gambro Renal Products, Inc.2010—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 39 years and passes through 5 companies; a new generation was cleared every 5.4 years on median.
  • 1 of the 7 ancestors has a recall of any class.

How does its category compare?

All FIP devices

FIP Subsystem, Water Purification: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · FIP

4in 2025

2007: 12008: 32009: 32010: 22011: 42012: 22013: 42014: 42015: 22016: 22017: 12018: 12019: 22020: 12021: 12022: 12023: 32024: 12025: 4
2007high 4 (2011) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FIP

88in 2025

2008: 202 days median2009: 167 days median2011: 116 days median2013: 125 days median2014: 126 days median2023: 69 days median2025: 88 days median
2007high 202 (2008) · low 69 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FIP

1in 2020

2020: 1
2007high 1 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FIP

77in 2025

2007: 12008: 52010: 122011: 42012: 42013: 412014: 342015: 122016: 32017: 62018: 32019: 132020: 122021: 352022: 572023: 1402024: 1742025: 77
2007high 174 (2024) · low 0 (2009)2025

MAUDE reports naming product code FIP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—01
2008320205
2009316700
20102—012
2011411604
20122—04
20134125041
20144126034
20152—012
20162—03
20171—06
20181—03
20192—013
20201—112
20211—035
20221—057
20233690140
20241—0174
2025488077
20260—0—

What is it indicated for?

The EON Portable Reverse Osmosis Water Purification System is intended to be used as a dialysis accessory to produce water through reverse osmosis for use with hemodialysis equipment. EON can be connected to hemodialysis equipment used in hospitals, clinics and in home environments, in conjunction with the appropriate pre and post treatment units, as part of a water treatment system designed to meet current AAMI and Federal (U.S.) standards. EON has…

Read the full statement (139 words)

The EON Portable Reverse Osmosis Water Purification System is intended to be used as a dialysis accessory to produce water through reverse osmosis for use with hemodialysis equipment. EON can be connected to hemodialysis equipment used in hospitals, clinics and in home environments, in conjunction with the appropriate pre and post treatment units, as part of a water treatment system designed to meet current AAMI and Federal (U.S.) standards.

EON has optional heat disinfection cycles intended to disinfect the reverse osmosis (RO) machine and product loop, and connection tubing to the hemodialysis machine. EON’s heat disinfection cycle to disinfect the connection tubing (heat forward cycle) is intended to be used only with hemodialysis machines which contain their own heat disinfection cycles and hence are able to tolerate high temperatures. EON is not intended to heat disinfect the hemodialysis machine.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K200670: EON Portable RO Water Purification System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K200670

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026