# K200714: AVIEW

- Pathway: 510(k) (Traditional)
- Applicant: Coreline Soft Co., Ltd.
- Decided: Aug 26, 2020 after 161 days
- Product code: LLZ (System, Image Processing, Radiological)
- Device class: 2
- Regulation: 21 CFR 892.2050
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 9 generations back to K954355 (1995). 13 ancestors in all.
5 later devices descend from it; 1 cites it directly.
0 of 19 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K171199: AVIEW, Coreline Soft Co., Ltd. (2018) Summary page 5.

## Most influential descendants
- K214036: AVIEW (2022), 4 descendants of its own
- K233211: Aview Cac (2024), 2 descendants of its own
- K250288: TeraRecon Cardiovascular.Calcification.CT (2025), 0 descendants of its own
- K243689: AVIEW (2025), 0 descendants of its own
- K243696: Aview Cac (2025), 0 descendants of its own

## Indications for use
AVIEW provides CT values for pulmonary tissue from CT thoracic and cardiac datasets. This software could be used to support the physician quantitatively in the diagnosis, follow up evaluation and documentation of CT lung tissue images by providing image segmentation of sub-structures in lung, lobe, airways and cardiac, registration of inspiration and expiration which could analyze quantitative information such as air trapping volume, air trapped index, and inspiration/expiration ratio. And also, volumetric and structure analysis, density evaluation and reporting tools. AVIEW is also used to store, transfer, inquire and display CT data set on premise and as cloud environment as well to allow users to connect by various environment such as mobile devices and chrome browser. Characterizing nodules in the lung in a single study, or over the time course of several thoracic studies. Characterizations include nodule type, location of the nodule and measurements such as size (major axis, minor axis), estimated effective diameter from the volume of the nodule, volume of the nodule, Mean HU(the average value of the CT pixel inside the nodule in HU), Minimum HU, Max HU, mass(mass calculated from the CT pixel value), and volumetric measures(Solid major; length of the longest diameter measured in 3D for solid portion of the nodule, Solid 2nd Major: The length of the longest diameter of the solid part, measured in sections perpendicular to the Major axis of the solid portion of the nodule), VDT (Volume doubling time), and Lung-RADS (classification proposed to aid with findings). The system automatically performs the measurement, allowing lung nodules and measurements to be displayed and, integrate with FDA certified Mevis CAD (Computer aided detection) (K043617). It also provides CAC analysis by segmentation of four main artery (right coronary artery, left main coronary, left anterior descending and left circumflex artery then extracts calcium on coronary artery to provide Agatston score, volume score and mass score by whole and each segmented artery type. Based on the score, provides CAC risk based on age and gender.