Ulab Systems, Inc. · PNN Orthodontic Software
Cleared on Jun 23, 2020 as substantially equivalent to K171295 (Ulab Systems, Inc., 2018) after a 90-day review. Its family tree reaches back 3 generations to 2009.
- Decided
- Jun 23, 2020
- Review
- 90 days
- Class
- Class II
- Product code
- PNN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K082207 (2009). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PNN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PNN device
- #1 K262196 Invisalign Systemscore 14.5 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K171295 | ULab Systems Treatment Planning SoftwareSummary page 4…ication Regulation: 21CFR 872.5470 Device Class: II Product Code: PNN, LLZ Primary Predicate: uLab Systems uDesign Software, K171295 Reference Device: 3Shape A/S Ortho System, K152086 Date Prepared: June 23, 2020 Device Description: The ULab Systems UDesign i… | 2018 |
| † | K152086 | 3Shape Ortho System | 2016 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 2.5 years on median.
- None of the 3 ancestors has a recall.
- 2 other devices also cite its predicate K171295.
How does its category compare?
All PNN devicesPNN Orthodontic Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · PNN
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PNN
177in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PNN
1in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PNN
1in 2024
MAUDE reports naming product code PNN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 1 | — | 0 | 0 |
| 2017 | 2 | — | 0 | 0 |
| 2018 | 5 | 229 | 0 | 0 |
| 2019 | 2 | — | 0 | 0 |
| 2020 | 7 | 221 | 0 | 0 |
| 2021 | 4 | 58 | 1 | 0 |
| 2022 | 1 | — | 1 | 0 |
| 2023 | 3 | 90 | 0 | 0 |
| 2024 | 4 | 177 | 0 | 1 |
| 2025 | 2 | — | 0 | 0 |
| 2026 | 6 | 98 | 0 | — |
What is it indicated for?
The uLab Systems uDesign is intended for use as a medical front-end device providing tools for management of orthodontic models. systematic inspection, detailed analysis, treatment simulation and virtual design of a series of dental casts, which may be used for sequential aligner trays or retainers, and of Indirect Bonding Transfer Media, based on 3D models of the patient’s dentition before the start of an orthodontic treatment. It can also be applied…
Read the full statement (141 words)
The uLab Systems uDesign is intended for use as a medical front-end device providing tools for management of orthodontic models. systematic inspection, detailed analysis, treatment simulation and virtual design of a series of dental casts, which may be used for sequential aligner trays or retainers, and of Indirect Bonding Transfer Media, based on 3D models of the patient’s dentition before the start of an orthodontic treatment. It can also be applied during the treatment to inspect and analyze the progress of the treatment. It can be used at the end of the treatment to evaluate if the outcome is consistent with the planned/desired treatment objectives. The use of uLab Systems uDesign requires the user to have the necessary training and domain knowledge in the practice of orthodontics, as well to have received a dedicated training in the use of the software.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K200772 · printed Nov 6, 2026
Cite this page
510(k) Report. “K200772: ULab Systems uDesign Software.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K200772
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026