510(k) Report

510(k) · Cleared

Cleared

MIRA Adapter

K200911510(k) TraditionalCleared Jun 2, 202057-day reviewClass II21 CFR 886.4170

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Phakos · HRN Unit, Cryophthalmic, Ac-Powered

Cleared on Jun 2, 2020 as substantially equivalent to K162756 (Phakos, 2017) and 1 other predicate after a 57-day review. Its family tree reaches back 4 generations to 1988.

Decided
Jun 2, 2020
Review
57 days
Class
Class II
Product code
HRN
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K874555 (1988). 6 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK874555 Keeler Acu 22XT Ophthalmic Cryo UnitKeeler Instruments, Inc. · 1988
  2. 3 generations backK062412 CryomaticKeeler Instruments, Inc. · 2006
  3. 2 generations backK162756 PHAKOS Disposable Retinal Cryo ProbePhakos · 2017
  4. 1 generation backK180195 Frigitronics adapterPhakos · 2018
  5. This deviceK200911 MIRA AdapterPhakos · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K874555Keeler Acu 22XT Ophthalmic Cryo UnitKeeler Instruments, Inc.1988—
−3K062412CryomaticKeeler Instruments, Inc.2006—
−2K162756PHAKOS Disposable Retinal Cryo ProbePhakos2017—
−1K180195Frigitronics adapterPhakos2018—
0 (this device)K200911MIRA AdapterPhakos2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910
201110
FIG. 1 — Lineage of K200911, 1988–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HRN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K162756PHAKOS Disposable Retinal Cryo Probe
Summary page 4
…HRN CFR Section 21 CFR section 886.4170 Device Panel Ophthalmic Primary Predicate PHAKOS Disposable Retinal Cryo Probe (K162756) Device Reference Predicates FRIGITRONICS ADAPTER (K180195) The cryoprobe ADAPTER is a mechanic…
Phakos2017—
*K180195Frigitronics adapter
Summary page 4
…0 Device Panel Ophthalmic Primary Predicate PHAKOS Disposable Retinal Cryo Probe (K162756) Device Reference Predicates FRIGITRONICS ADAPTER (K180195) The cryoprobe ADAPTER is a mechanical accessory used to adapt the PHAKOS…
Phakos2018—

Also cleared against K162756: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 32 years and passes through 2 companies; a new generation was cleared every 10.5 years on median.
  • None of the 6 ancestors has a recall.
  • 1 other device also cites its predicate K162756.

How does its category compare?

All HRN devices

HRN Unit, Cryophthalmic, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · HRN

1in 2020

2011: 12013: 12017: 22018: 12020: 1
2007high 2 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HRN

Too few HRN 510(k)s in any year since 2007 to give a median.

Recalls per year · HRN

No recall names HRN since 2007.

Adverse event reports per year · HRN

1in 2019

2015: 22019: 1
2007high 2 (2015) · low 0 (2007)2025

MAUDE reports naming product code HRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20111—00
20120—00
20131—00
20140—00
20150—02
20160—00
20172—00
20181—00
20190—01
20201—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The PHAKOS Disposable Retinal Cryo Probe and Accessories is for use in ophthalmic surgery in cryopexy for retinal detachment, cyclo destructive procedures in refractory glaucoma, extraction of fragments within the vitreous cavity, cataract extraction, and cryo destruction of lash follicles for trichiasis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K200911: MIRA Adapter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K200911

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026