Clarus Peel-Away Introducer Sheath

K200925510(k) TraditionalCleared Mar 18, 2021345-day reviewClass II21 CFR 882.1480

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Clarus Medical, LLC · GWG Endoscope, Neurological

Cleared on Mar 18, 2021 as substantially equivalent to K990333 (Medtronic PS Medical, 1999) after a 345-day review. Its family tree reaches back 2 generations to 1988.

Decided
Mar 18, 2021
Review
345 days
Class
Class II
Product code
GWG
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K883607 (1988). 3 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 2 generations backK883607 Peel-Away Introducer for Ventricular CatheterCodman & Shurtleff, Inc. · 1988
  2. 1 generation backK990333 Medtronic PS Medical Introducer Sheath 12F,14F,15F, Models 3805-012…Medtronic PS Medical · 1999 · Recalled
  3. This deviceK200925 Clarus Peel-Away Introducer SheathClarus Medical, LLC · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K883607Peel-Away Introducer for Ventricular CatheterCodman & Shurtleff, Inc.1988—
−1K990333Medtronic PS Medical Introducer Sheath 12F,14F,15F, Models 3805-012, 3805-014…Medtronic PS Medical19992
0 (this device)K200925Clarus Peel-Away Introducer SheathClarus Medical, LLC2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
FIG. 1 — Lineage of K200925, 1988–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWG device

  1. #1 K211202 1688 4K Camera System, L11 LED Light Source…score 22.5 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K990333Medtronic PS Medical Introducer Sheath 12F,14F,15F, Models 3805-012, 3805-014, 3805-015
Summary page 4
…: 882.1480 Class: II C. Predicate Device: 510(k) Number Description K990333 Medtronic Peelaway Introducer Sheath D. Reference Devices: 510(k) Number Description…
Medtronic PS Medical19992
†K883607Peel-Away Introducer for Ventricular CatheterCodman & Shurtleff, Inc.1988—
†K120617Ptfe Super Sheath IntroducerMartech Medical Products2012—

Also cleared against K990333: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 33 years and passes through 3 companies; a new generation was cleared every 21.9 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 1 other device also cites its predicate K990333.

How does its category compare?

All GWG devices

GWG Endoscope, Neurological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · GWG

2in 2025

2008: 22013: 12014: 22016: 22017: 42018: 42019: 32020: 22021: 32023: 52024: 12025: 22026 (partial year): 4
2007high 5 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWG

269in 2023

2017: 126 days median2018: 128 days median2019: 156 days median2021: 106 days median2023: 269 days median2026 (partial year): 217 days median
2007high 269 (2023) · low 106 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWG

2in 2011

2009: 12011: 2
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWG

33in 2025

2007: 32008: 52010: 12011: 42012: 72013: 32014: 192015: 372016: 252017: 122018: 162019: 102020: 192021: 212022: 122023: 92024: 92025: 33
2007high 37 (2015) · low 0 (2009)2025

MAUDE reports naming product code GWG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20082—05
20090—10
20100—01
20110—24
20120—07
20131—03
20142—019
20150—037
20162—025
20174126012
20184128016
20193156010
20202—019
20213106021
20220—012
2023526909
20241—09
20252—033
202642170—

What is it indicated for?

The Clarus Peel-Away Introducer Sheath is intended to be used in indications requiring access through the brain into the ventricular system.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K200925: Clarus Peel-Away Introducer Sheath.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K200925

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026