510(k) Report

510(k) · Cleared

Cleared

Safey Pocket Spirometer

K201002510(k) TraditionalCleared Jul 30, 2020105-day reviewClass II21 CFR 868.1840

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Safey Medical Devices Pvt, Ltd. · BZG Spirometer, Diagnostic

Cleared on Jul 30, 2020 as substantially equivalent to K072979 (Mir Medical Intl. Research Srl, 2007) after a 105-day review. Its family tree reaches back 5 generations to 1994.

Decided
Jul 30, 2020
Review
105 days
Class
Class II
Product code
BZG
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K943404 (1994). 10 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backK943404 3301 Pulse OximeterBci Intl., Inc. · 1994
  2. 4 generations backK013171 3420 Digit Pulse Oximeter, Model 3420Bci, Inc. · 2002
  3. 3 generations backK043528 SpirotelMir Medical Intl. Research Srl · 2005
  4. 2 generations backK061712 Spirobank IIMir Medical Intl. Research Srl · 2006
  5. 1 generation backK072979 Spirobank GMir Medical Intl. Research Srl · 2007
  6. This deviceK201002 Safey Pocket SpirometerSafey Medical Devices Pvt, Ltd. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K9434043301 Pulse OximeterBci Intl., Inc.1994—
−4K0131713420 Digit Pulse Oximeter, Model 3420Bci, Inc.2002—
−3K043528SpirotelMir Medical Intl. Research Srl2005—
−2K061712Spirobank IIMir Medical Intl. Research Srl2006—
−1K072979Spirobank GMir Medical Intl. Research Srl2007—
0 (this device)K201002Safey Pocket SpirometerSafey Medical Devices Pvt, Ltd.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199820
200010
200310
FIG. 1 — Lineage of K201002, 1994–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BZG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZG device

  1. #1 K251777 MESI mTABLET SPIROscore 13.0 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K072979Spirobank G
Summary page 5
…Regulatory Class II; per 21 CFR 868.1840 Product Code: BZG Predicate Device Spirobank G (K072979) 3) Device Description Safey Pocket Spirometer is a prescription use medical device to help respiratory patients keep track of t…
Mir Medical Intl. Research Srl2007—

Also cleared against K072979: 6 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 4 companies; a new generation was cleared every 3.5 years on median.
  • None of the 10 ancestors has a recall.
  • 6 other devices also cite its predicate K072979.

How does its category compare?

All BZG devices

BZG Spirometer, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · BZG

2in 2024

2007: 32008: 32009: 82010: 42011: 62012: 32013: 32014: 52015: 52016: 42017: 22018: 12019: 32020: 52021: 12022: 22023: 52024: 22026 (partial year): 1
2007high 8 (2009) · low 0 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZG

362in 2023

2007: 121 days median2008: 209 days median2009: 141 days median2010: 181 days median2011: 278 days median2012: 59 days median2013: 266 days median2014: 154 days median2015: 273 days median2016: 235 days median2019: 146 days median2020: 126 days median2023: 362 days median
2007high 362 (2023) · low 59 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZG

1in 2024

2024: 1
2007high 1 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · BZG

1in 2025

2007: 12011: 12012: 22013: 12014: 12015: 12016: 12017: 12018: 12019: 12020: 22021: 12022: 32023: 22024: 32025: 1
2007high 3 (2022) · low 0 (2008)2025

MAUDE reports naming product code BZG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007312101
2008320900
2009814100
2010418100
2011627801
201235902
2013326601
2014515401
2015527301
2016423501
20172—01
20181—01
2019314601
2020512602
20211—01
20222—03
2023536202
20242—13
20250—01
20261—0—

What is it indicated for?

Safey Pocket Spirometer is a spirometer intended to be used by a patient under the instruction of a physician to perform basic lung function and spirometry testing for users above 5 years of age in home healthcare environment.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K201002: Safey Pocket Spirometer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K201002

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026