510(k) Report

510(k) · Cleared

Cleared

iMap 3D Mapping & Navigation System (iMap System)

K201094510(k) TraditionalCleared Aug 16, 2021479-day reviewClass II21 CFR 870.1425

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cardionxt, Inc. · DQK Computer, Diagnostic, Programmable

Cleared on Aug 16, 2021 as substantially equivalent to K160210 (St Jude Medical, 2016) and 2 other predicates after a 479-day review. Its family tree reaches back 6 generations to 2010.

Decided
Aug 16, 2021
Review
479 days
Class
Class II
Product code
DQK
Recalls
None
Predicates
3

Its longest line of descent runs back 6 generations to K093942 (2010). 10 ancestors in all, the oldest K961924 (1997). No later device cites it as a predicate yet.

  1. Root · 6 generations backK093942 Ensite Velocity System V1.3St Jude Medical · 2010
  2. 5 generations backK101667 Ensite Velocity System Referred to Ensite Velocity System with…St Jude Medical · 2010
  3. 4 generations backK112688 Ensite Velocity System V.3.0St Jude Medical · 2011
  4. 3 generations backK130594 Ensite Velocity SystemSt Jude Medical · 2013
  5. 2 generations backK141050 Ensite Velocity SystemSt Jude Medical · 2014
  6. 1 generation backK160186 EnSite Velocity Surface Electrode KitSt Jude Medical · 2016
  7. This deviceK201094 iMap 3D Mapping & Navigation System (iMap System)Cardionxt, Inc. · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K093942Ensite Velocity System V1.3St Jude Medical2010—
−5K101667Ensite Velocity System Referred to Ensite Velocity System with Positional…St Jude Medical2010—
−4K112688Ensite Velocity System V.3.0St Jude Medical2011—
−3K130594Ensite Velocity SystemSt Jude Medical2013—
−2K141050Ensite Velocity SystemSt Jude Medical2014—
−1K160186EnSite Velocity Surface Electrode KitSt Jude Medical2016—
0 (this device)K201094iMap 3D Mapping & Navigation System (iMap System)Cardionxt, Inc.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
201010
201210
201610
FIG. 1 — Lineage of K201094, 2010–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQK device

  1. #1 K213682 HemoSphere Advanced Monitor, HemoSphere…score 26.6 · 28 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K160210EnSite Precision Cardiac Mapping System v2.0
Summary page 4
…ondary Predicate EnSite Precision™ Cardiac Mapping System Primary Abbot St. Jude K160210 EnSite™ Velocity Cardiac Mapping System with EnSite™ Secondary Abbot St. Jude K160186 Velocity Surface Electrode K…
St Jude Medical2016—
*K160186EnSite Velocity Surface Electrode Kit
Summary page 4
…rdiac Mapping System Primary Abbot St. Jude K160210 EnSite™ Velocity Cardiac Mapping System with EnSite™ Secondary Abbot St. Jude K160186 Velocity Surface Electrode Kit (Commonly known as the NavX System) IBI Inquiry Diagnostic Catheter (Secondary Predicate)…
St Jude Medical2016—
*K961924Ibi-1100 Steerable Electrophysiology Catheter System
Summary page 4
…K160186 Velocity Surface Electrode Kit (Commonly known as the NavX System) IBI Inquiry Diagnostic Catheter (Secondary Predicate) Secondary Abbot St. Jude K961924 Page 1 of 6…
Irvine Biomedical, Inc.19972

Also cleared against K160210: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 1.5 years on median.
  • 1 of the 10 ancestors has a recall of any class.
  • 1 other device also cites its predicate K160210.

How does its category compare?

All DQK devices

DQK Computer, Diagnostic, Programmable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · DQK

23so far in 2026, the most since 2007

2007: 132008: 42009: 122010: 92011: 122012: 72013: 132014: 92015: 72016: 152017: 72018: 142019: 152020: 162021: 162022: 192023: 212024: 132025: 222026 (partial year): 23
2007high 23 (2026) · low 4 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQK

95in 2025

2007: 83 days median2008: 70 days median2009: 93 days median2010: 64 days median2011: 69 days median2012: 74 days median2013: 68 days median2014: 90 days median2015: 125 days median2016: 190 days median2017: 146 days median2018: 150 days median2019: 113 days median2020: 123 days median2021: 132 days median2022: 136 days median2023: 133 days median2024: 100 days median2025: 95 days median2026 (partial year): 151 days median
2007high 190 (2016) · low 64 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQK

1in 2025

2007: 42008: 12009: 22010: 32011: 22012: 32013: 12014: 42015: 22017: 22018: 62019: 12020: 12021: 12022: 22023: 22024: 242025: 12026 (partial year): 2
2007high 24 (2024) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQK

433in 2025

2007: 182008: 342009: 402010: 492011: 552012: 1292013: 1802014: 1152015: 1312016: 3402017: 2522018: 2612019: 2182020: 2152021: 3512022: 3192023: 3402024: 5572025: 433
2007high 557 (2024) · low 18 (2007)2025

MAUDE reports naming product code DQK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071383418
2008470134
20091293240
2010964349
20111269255
20127743129
201313681180
20149904115
201571252131
2016151900340
201771462252
2018141506261
2019151131218
2020161231215
2021161321351
2022191362319
2023211332340
20241310024557
202522951433
2026231512—

What is it indicated for?

The CardioNXT iMap™ 3D Mapping & Navigation System is intended for the display of compatible electrophysiology catheter position and cardiac electrical activity when used with the MultiLink CS Catheter during conventional electrophysiological procedures.

The MultiLink CS Catheter is used for electrogram recording and as a navigation reference during conventional electrophysiological procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K201094: iMap 3D Mapping & Navigation System (iMap System).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K201094

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026