510(k) Report

510(k) · Cleared

Cleared

Bio-C Repair Ion+

K201222510(k) TraditionalCleared Feb 11, 2021281-day reviewClass II21 CFR 872.3820

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Angelus Industria DE Produtos Odontologicos S/A · KIF Resin, Root Canal Filling

Cleared on Feb 11, 2021 as substantially equivalent to K180185 (Angelus Industria DE Produtos Odontologicos S/A, 2018) after a 281-day review. Its family tree reaches back 9 generations to 1999.

Decided
Feb 11, 2021
Review
281 days
Class
Class II
Product code
KIF
Recalls
None
Predicates
1

Its longest line of descent runs back 9 generations to K990131 (1999). 33 ancestors in all, the oldest K852682 (1985). No later device cites it as a predicate yet.

  1. Root · 9 generations backK990131 Pro Osteon Implant 500R Resorbable Bone Graft SubstituteInterpore Cross Intl. · 1999
  2. 5 generations between
  3. 3 generations backK080917 Iroot SPInnovative Bioceramix, Inc. · 2008
  4. 2 generations backK082943 Iroot BP, Model Irbp 4609Innovative Bioceramix, Inc. · 2009
  5. 1 generation backK180185 Bio-C RepairAngelus Industria DE Produtos Odontologicos S/A · 2018
  6. This deviceK201222 Bio-C Repair Ion+Angelus Industria DE Produtos Odontologicos S/A · 2021
Show all 9 generations
  1. Root · 9 generations backK990131 Pro Osteon Implant 500R Resorbable Bone Graft SubstituteInterpore Cross Intl. · 1999
  2. 8 generations backK020986 Mastergraft Resorbable CeramicMedtronic Sofamor Danek, Inc. · 2002
  3. 7 generations backK032268 MBCPBiomatlante · 2003
  4. 6 generations backK043005 Modification to MBCPBiomatlante · 2005
  5. 5 generations backK051885 MBCPBiomatlante · 2005
  6. 4 generations backK060732 MBCP GelBiomatlante · 2006
  7. 3 generations backK080917 Iroot SPInnovative Bioceramix, Inc. · 2008
  8. 2 generations backK082943 Iroot BP, Model Irbp 4609Innovative Bioceramix, Inc. · 2009
  9. 1 generation backK180185 Bio-C RepairAngelus Industria DE Produtos Odontologicos S/A · 2018
  10. This deviceK201222 Bio-C Repair Ion+Angelus Industria DE Produtos Odontologicos S/A · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K990131Pro Osteon Implant 500R Resorbable Bone Graft SubstituteInterpore Cross Intl.1999—
−8K020986Mastergraft Resorbable CeramicMedtronic Sofamor Danek, Inc.2002—
−7K032268MBCPBiomatlante2003—
−6K043005Modification to MBCPBiomatlante2005—
−5K051885MBCPBiomatlante2005—
−4K060732MBCP GelBiomatlante2006—
−3K080917Iroot SPInnovative Bioceramix, Inc.2008—
−2K082943Iroot BP, Model Irbp 4609Innovative Bioceramix, Inc.2009—
−1K180185Bio-C RepairAngelus Industria DE Produtos Odontologicos S/A2018—
0 (this device)K201222Bio-C Repair Ion+Angelus Industria DE Produtos Odontologicos S/A2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198920
199310
199520
199630
199720
199810
199910
200020
200140
200440
200610
FIG. 1 — Lineage of K201222, 1999–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KIF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KIF device

  1. #1 K250710 Injectable Root Canal Bioceramic Sealer (nRoot…score 14.9 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K180185Bio-C Repair
Summary page 4
…Primary Predicate Device: Reference Device: BIO-C REPAIR ION* Root Canal Filling Resin 21 CFR 872-3820, Class II KIF Dental Products Panel Dental Devices Branch K180185 BIO-C REPAIR (Angelus Industria de Produtos Odontoldgicos S/A) K190537 BIO-C SEALER ION* (Angelus Industria de Produtos Odontold…
Angelus Industria DE Produtos Odontologicos S/A2018—
†K190537BIO-C Sealer Ion+Angelus Industria DE Produtos Odontologicos S/A2019—

Also cleared against K180185: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 5 companies; a new generation was cleared every 1.4 years on median.
  • None of the 33 ancestors has a recall.
  • 1 other device also cites its predicate K180185.

How does its category compare?

All KIF devices

KIF Resin, Root Canal Filling: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · KIF

7in 2025

2007: 22008: 42009: 52010: 52012: 52013: 22014: 102015: 12016: 52017: 32018: 52019: 72020: 32021: 122022: 32023: 72024: 82025: 72026 (partial year): 7
2007high 12 (2021) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KIF

90in 2025

2008: 31 days median2009: 94 days median2010: 75 days median2012: 172 days median2014: 220 days median2016: 212 days median2017: 211 days median2018: 147 days median2019: 252 days median2020: 239 days median2021: 89 days median2022: 152 days median2023: 59 days median2024: 96 days median2025: 90 days median2026 (partial year): 108 days median
2007high 252 (2019) · low 31 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KIF

1in 2009

2009: 1
2007high 1 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KIF

55in 2025

2008: 22009: 72010: 102011: 82012: 42013: 792014: 4212015: 152016: 52017: 52018: 132019: 62020: 32021: 92022: 102023: 72024: 102025: 55
2007high 421 (2014) · low 0 (2007)2025

MAUDE reports naming product code KIF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
200843102
200959417
2010575010
20110—08
2012517204
20132—079
2014102200421
20151—015
2016521205
2017321105
20185147013
2019725206
2020323903
2021128909
20223152010
202375907
2024896010
2025790055
202671080—

What is it indicated for?

Furcation or root perforation treatment via canal;

Furcation or root perforation treatment via surgical;

Internal reabsorption treatment via canal or surgical;

External reabsorption treatment;

Retrofilling in parendodontic surgery;

Direct and indirect pulp capping;

Apexification;

Apexogenesis and Pulpotomy.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K201222: Bio-C Repair Ion+.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K201222

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026