Plastic LOR Syringe

K201356510(k) TraditionalCleared Feb 12, 2021267-day reviewClass II21 CFR 868.5140

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Jiangsu Caina Medical Co.,Ltd · CAZ Anesthesia Conduction Kit

Cleared on Feb 12, 2021 as substantially equivalent to K061737 (Robert Busse & Co., Inc., 2006) and 1 other predicate after a 267-day review. Its family tree reaches back 3 generations to 1993.

Decided
Feb 12, 2021
Review
267 days
Class
Class II
Product code
CAZ
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K925902 (1993). No later device cites it as a predicate yet.

  1. Root · 3 generations backK925902 B-D Loss of Resistance SyringeBd Becton Dickinson Vacutainer Systems Preanalytic · 1993
  2. 2 generations backK061737 Loss of Resistance SyringeRobert Busse & Co., Inc. · 2006
  3. 1 generation backK190345 VPCPAJUNK GmbH Medizintechnologie · 2019
  4. This deviceK201356 Plastic LOR SyringeJiangsu Caina Medical Co.,Ltd · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K925902B-D Loss of Resistance SyringeBd Becton Dickinson Vacutainer Systems Preanalytic1993—
−2K061737Loss of Resistance SyringeRobert Busse & Co., Inc.2006—
−1K190345VPCPAJUNK GmbH Medizintechnologie2019—
0 (this device)K201356Plastic LOR SyringeJiangsu Caina Medical Co.,Ltd2021—
FIG. 1 — Lineage of K201356, 1993–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CAZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CAZ device

  1. #1 K261372 Profoject™ LOR Syringescore 12.4 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K061737Loss of Resistance Syringe
Summary page 5
…ring the shelf life of five years. The intended patient population is adults. 5. Identification of Predicate Device Predicate device 1 510(k) Number: K061737 2 / 9…
Robert Busse & Co., Inc.2006—
*K190345VPC
Summary page 6
…K201356 Page 3 of 9 Product Name: Busse Loss of Resistance Syringe Predicate device 2 510(k) Number: K190345 Product Name: VPC 6. Non-Clinical Test Conclusion Non clinical tests were conducted to verify that the proposed de…
PAJUNK GmbH Medizintechnologie2019—

Also cleared against K061737: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 4 companies; a new generation was cleared every 12.4 years on median.
  • None of the 3 ancestors has a recall.
  • 3 other devices also cite its predicate K061737.

How does its category compare?

All CAZ devices

CAZ Anesthesia Conduction Kit: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · CAZ

1in 2023

2007: 42008: 42009: 22010: 22011: 12012: 92015: 12016: 22019: 12020: 12021: 12022: 12023: 12026 (partial year): 1
2007high 9 (2012) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CAZ

108in 2012

2007: 172 days median2008: 99 days median2012: 108 days median
2007high 172 (2007) · low 99 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CAZ

1in 2024

2009: 292010: 82011: 22013: 122014: 22015: 12016: 12024: 12026 (partial year): 12, 11 Class I
2007high 29 (2009) · low 0 (2007)2026

Class I (11 since 2007) Class II/III not classified

Adverse event reports per year · CAZ

137in 2025

2007: 812008: 802009: 1342010: 1392011: 1872012: 1872013: 2762014: 2512015: 2352016: 3722017: 3532018: 4482019: 4722020: 2742021: 1652022: 2702023: 602024: 1652025: 137
2007high 472 (2019) · low 60 (2023)2025

MAUDE reports naming product code CAZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074172081
2008499080
20092—29134
20102—8139
20111—2187
201291080187
20130—12276
20140—2251
20151—1235
20162—1372
20170—0353
20180—0448
20191—0472
20201—0274
20211—0165
20221—0270
20231—060
20240—1165
20250—0137
20261—12 (11)—

What is it indicated for?

The Plastic LOR Syringe is intended for use in conjunction with an epidural needle, to verify the needle tip placement in the epidural space by the loss of Resistance technique, it will be filled with air and/or saline during use. The loss of Resistance Syringe is not intended for injection or aspiration. The syringe will be sold sterile individually packaged, and as part of a sterile kit.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K201356: Plastic LOR Syringe.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K201356

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026