510(k) Report

510(k) · Cleared

Cleared

Easytech® Anatomical Shoulder System

K201391510(k) TraditionalCleared Feb 16, 2021265-day reviewClass II21 CFR 888.3660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fx Shoulder USA, Inc. · PKC Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained

Cleared on Feb 16, 2021 as substantially equivalent to K183194 (Arthrex, Inc., 2019) after a 265-day review. Its family tree reaches back 8 generations to 1991.

Decided
Feb 16, 2021
Review
265 days
Class
Class II
Product code
PKC
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K911686 (1991). 25 ancestors in all, the oldest K790987 (1979). No later device cites it as a predicate yet.

  1. Root · 8 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
  2. 7 generations backK984541 Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc. · 1999
  3. 6 generations backK992065 Global Advantage Shoulder, Global Advantage Humeral Stem, Global…DePuy Orthopaedics, Inc. · 1999
  4. 5 generations backK060988 Total and Hemi Shoulder SystemDvo Extremity Solutions, LLC · 2006 · Recalled
  5. 4 generations backK103007 Affiniti Total and Hemi-Shoulder SystemTornier, Inc. · 2010
  6. 3 generations backK143552 Simpliciti Shoulder SystemTornier, Inc. · 2015
  7. 2 generations backK171858 Sidus Stem-Free ShoulderZimmer GmbH · 2017 · Recalled
  8. 1 generation backK183194 Arthrex Eclipse Shoulder Prosthesis SystemArthrex, Inc. · 2019
  9. This deviceK201391 Easytech® Anatomical Shoulder SystemFx Shoulder USA, Inc. · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K911686Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc.1991—
−7K984541Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc.1999—
−6K992065Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage…DePuy Orthopaedics, Inc.1999—
−5K060988Total and Hemi Shoulder SystemDvo Extremity Solutions, LLC200613
−4K103007Affiniti Total and Hemi-Shoulder SystemTornier, Inc.2010—
−3K143552Simpliciti Shoulder SystemTornier, Inc.2015—
−2K171858Sidus Stem-Free ShoulderZimmer GmbH20173
−1K183194Arthrex Eclipse Shoulder Prosthesis SystemArthrex, Inc.2019—
0 (this device)K201391Easytech® Anatomical Shoulder SystemFx Shoulder USA, Inc.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198610
198710
198910
199120
199210
199310
199510
199640
199820
200110
200710
FIG. 1 — Lineage of K201391, 1991–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PKC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PKC device

  1. #1 K240716 AETOS Shoulder System Stemless Humeral…score 22.2 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K183194Arthrex Eclipse Shoulder Prosthesis System
Summary page 4
…ed cemented prosthesis – Class II Substantially Equivalent Devices: Primary Predicate: Arthrex Eclipse (K183194) Reference Device: Tornier Simpliciti™ Shoulder System…
Arthrex, Inc.2019—
†K143552Simpliciti Shoulder SystemTornier, Inc.2015—
†K163669Humeris ShoulderFx Solutions2017—

Also cleared against K183194: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 7 companies; a new generation was cleared every 3.9 years on median.
  • 5 of the 25 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K183194.

How does its category compare?

All PKC devices

PKC Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · PKC

1in 2025

2015: 12017: 12018: 12019: 12020: 42021: 22022: 32023: 12024: 32025: 12026 (partial year): 2
2007high 4 (2020) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PKC

167in 2024

2020: 116 days median2022: 148 days median2024: 167 days median
2007high 167 (2024) · low 116 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PKC

1in 2019

2019: 1
2007high 1 (2019) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PKC

86in 2025

2017: 12018: 52019: 82020: 52021: 142022: 312023: 462024: 542025: 86
2007high 86 (2025) · low 0 (2007)2025

MAUDE reports naming product code PKC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20151—00
20160—00
20171—01
20181—05
20191—18
2020411605
20212—014
20223148031
20231—046
20243167054
20251—086
20262—0—

What is it indicated for?

The Easytech® Anatomical Shoulder System is indicated for use in total shoulder replacement to treat a severely painful and/or disabled joint resulting from osteoarthritis.

The humeral stemless of the Easytech® Anatomical Shoulder is intended for cementless use only. The glenoid components of the Easytech® Anatomical Shoulder System are intended for cemented use only.

The patient’s joint must be anatomically and structurally suited to receive the selected implants and a functional rotator cuff is necessary to use the device.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K201391: Easytech® Anatomical Shoulder System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K201391

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026