DSG Connect Technology

K201454510(k) TraditionalCleared Feb 10, 2021254-day reviewClass II21 CFR 874.1820

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Spineguard S.A. · PDQ Neurosurgical Nerve Locator

Cleared on Feb 10, 2021 as substantially equivalent to K143159 (Spineguard S.A., 2015) and 2 other predicates after a 254-day review. Its family tree reaches back 8 generations to 1993. 1 later device descends from it.

Decided
Feb 10, 2021
Review
254 days
Class
Class II
Product code
PDQ
Recalls
None
Predicates
3

Its longest line of descent runs back 8 generations to K921979 (1993). 11 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 8 generations backK921979 Root ZXJ. Morita USA, Inc. · 1993
  2. 7 generations backK972407 Root Apex LocatorToei Electric Co., Ltd. · 1997
  3. 6 generations backK022020 Justwo Model Tme-601 Root Apex LocatorToei Electric Co., Ltd. · 2002
  4. 5 generations backK030526 Pediguard Nerve Detector SystemSpine Vision, Inc. · 2004
  5. 4 generations backK123390 Pediguard Nerve Detector SystemSpineguard S.A. · 2013
  6. 3 generations backK143159 Cannulated PediGuard Needle#1, Cannulated PediGuard Needle#2…Spineguard S.A. · 2015
  7. 2 generations backK152747 DSG Threaded Drill SystemSpineguard S.A. · 2016
  8. 1 generation backK162884 SpineGuard DSG Zavation Screw SystemSpineguard S.A. · 2017
  9. This deviceK201454 DSG Connect TechnologySpineguard S.A. · 2021
  10. Descendant · cites it directly · 0 of its ownK222106 Waypoint GPSWaypoint Orthopedics, Inc. · 2023

Most influential descendants

Showing 1 of 1 · See all
  • K222106Waypoint GPSWaypoint Orthopedics, Inc. · 2023 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K921979Root ZXJ. Morita USA, Inc.1993—
−7K972407Root Apex LocatorToei Electric Co., Ltd.1997—
−6K022020Justwo Model Tme-601 Root Apex LocatorToei Electric Co., Ltd.2002—
−5K030526Pediguard Nerve Detector SystemSpine Vision, Inc.2004—
−4K123390Pediguard Nerve Detector SystemSpineguard S.A.2013—
−3K143159Cannulated PediGuard Needle#1, Cannulated PediGuard Needle#2, Cannulated…Spineguard S.A.2015—
−2K152747DSG Threaded Drill SystemSpineguard S.A.2016—
−1K162884SpineGuard DSG Zavation Screw SystemSpineguard S.A.2017—
0 (this device)K201454DSG Connect TechnologySpineguard S.A.2021—
+1K222106Waypoint GPSWaypoint Orthopedics, Inc.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199810
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
FIG. 1 — Lineage of K201454, 1993–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PDQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PDQ device

  1. #1 K243636 Neuralytix iD3 System (NTX-9001)score 16.5 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K143159Cannulated PediGuard Needle#1, Cannulated PediGuard Needle#2, Cannulated PediGuard…
Summary page 5
…tor Classification Name: 21 C.F.R. §874.1820 (Surgical Nerve stimulator/ locator) Regulatory Class: Class II Product Code: PDQ, ETN III. Predicate Devices K143159, PediGuard devices, SpineGuard SA K143159, Cannulated PediGuard devices, SpineGuard SA K152747, PediGuard Threade…
Spineguard S.A.2015—
*K152747DSG Threaded Drill System
Summary page 5
…Product Code: PDQ, ETN III. Predicate Devices K143159, PediGuard devices, SpineGuard SA K143159, Cannulated PediGuard devices, SpineGuard SA K152747, PediGuard Threaded systems, SpineGuard SA K162884, DSG Zavation screw system, SpineGuard SA IV. Device Description…
Spineguard S.A.2016—
*K162884SpineGuard DSG Zavation Screw System
Summary page 5
…K143159, PediGuard devices, SpineGuard SA K143159, Cannulated PediGuard devices, SpineGuard SA K152747, PediGuard Threaded systems, SpineGuard SA K162884, DSG Zavation screw system, SpineGuard SA IV. Device Description The DSG Connect technology is a pedicle screw system used…
Spineguard S.A.2017—

Also cleared against K143159: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K222106Waypoint GPSWaypoint Orthopedics, Inc.20230

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 4 companies; a new generation was cleared every 4.1 years on median.
  • None of the 11 ancestors has a recall.
  • Of its descendants, K222106 (Waypoint Orthopedics, Inc., 2023) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K143159.

How does its category compare?

All PDQ devices

PDQ Neurosurgical Nerve Locator: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · PDQ

1in 2025

2013: 52014: 72015: 32016: 32017: 22018: 42019: 42021: 22022: 22023: 12025: 12026 (partial year): 2
2007high 7 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PDQ

182in 2019

2013: 181 days median2014: 254 days median2015: 95 days median2016: 100 days median2018: 162 days median2019: 182 days median
2007high 254 (2014) · low 95 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PDQ

No recall names PDQ since 2007.

Adverse event reports per year · PDQ

2in 2025

2013: 12015: 12016: 42017: 52018: 52019: 102020: 92021: 102022: 162023: 92024: 42025: 2
2007high 16 (2022) · low 0 (2007)2025

MAUDE reports naming product code PDQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
2013518101
2014725400
201539501
2016310004
20172—05
2018416205
20194182010
20200—09
20212—010
20222—016
20231—09
20240—04
20251—02
20262—0—

What is it indicated for?

PediGuard and PediGuard Cannulated systems: The PediGuard is indicated for use during pedicle screw pilot hole drilling to provide feedback to the surgeon via visual and audible alerts that indicate a change in impedance at the tip of the probe and may indicate contact of the tip with soft tissues and possible vertebral cortex perforation. The PediGuard system is indicated for use in both open and percutaneous (MIS) surgical approaches to the spine.…

Read the full statement (392 words)

PediGuard and PediGuard Cannulated systems:

The PediGuard is indicated for use during pedicle screw pilot hole drilling to provide feedback to the surgeon via visual and audible alerts that indicate a change in impedance at the tip of the probe and may indicate contact of the tip with soft tissues and possible vertebral cortex perforation. The PediGuard system is indicated for use in both open and percutaneous (MIS) surgical approaches to the spine. PediGuard is also indicated for use with fluoroscopic guidance in percutaneous (MIS) surgical approaches to the spine. The PediGuard also is specifically indicated for use in intraoperative electromyographic (“EMG”) surveillance to assist in the location and evaluation of spinal nerves during surgery of the spine, by administration of low voltage electrical energy to tissues and nerves at the operative site, and EMG monitoring of muscle groups associated with those nerves.

PediGuard Threaded System:

The PediGuard Threaded System is indicated for use during pedicle screw pilot hole drilling to provide feedback to the surgeon via visual and audible alerts that indicate a change in impedance at the tip of the probe and may indicate contact of the tip with soft tissues and possible vertebral cortex perforation. PediGuard Threaded System is indicated for use in both open and percutaneous (MIS) surgical approaches to the spine. PediGuard Threaded System is also indicated for use with fluoroscopic guidance in percutaneous (MIS) surgical approaches to the spine. PediGuard Threaded System also is specifically indicated for use in intraoperative electromyographic (“EMG”) surveillance to assist in the location and evaluation of spinal nerves during surgery of the spine, by administration of low voltage electrical energy to tissues and nerves at the operative site, and EMG monitoring of muscle groups associated with those nerves.

DSG Zavation screw system:

The Zavation Screw System is indicated for use with the Zavation Spinal System during pedicle screw insertion to provide feedback to the surgeon via visual and audible alerts that indicate a change in impedance at the tip of the pedicle screw and may indicate contact of the tip with soft tissues and possible vertebral cortex perforation. The Zavation Screw System is indicated for use in both open and percutaneous (MIS) surgical approaches to the spine, with options of direct insertion of the screw in bone or after a step of preparation of the pilot hole with sensor equipped instruments.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K201454: DSG Connect Technology.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K201454

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026