510(k) Report

510(k) · Cleared

Cleared

imani i2

K202037510(k) TraditionalCleared Mar 1, 2021221-day reviewClass II21 CFR 884.5160

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Imani Co. · HGX Pump, Breast, Powered

Cleared on Mar 1, 2021 as substantially equivalent to K181863 (Chiaro Technology Limited, 2018) after a 221-day review. Its family tree reaches back 7 generations to 1980. 2 later devices descend from it.

Decided
Mar 1, 2021
Review
221 days
Class
Class II
Product code
HGX
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K801862 (1980). 11 ancestors in all. 2 later devices descend from it, 1 citing it directly.

  1. Root · 7 generations backK801862 Medela Electric Breast PumpMedela, Inc. · 1980 · Recalled
  2. 6 generations backK020518 Medela Symphony Breast Pump, Model 024Medela, Inc. · 2002 · Recalled
  3. 5 generations backK053052 Medela Swing Breast PumpMedela AG · 2006
  4. 4 generations backK092783 DEBPEnko, Ltd. · 2009
  5. 3 generations backK122474 Lansinoh Powered Electric Breast PumpLansinoh Laboratories Saglik Gerecleri Tasarim San · 2012
  6. 2 generations backK150499 Freestyle Deluxe, Freestyle Solution Set, Freestyle Basic, Freestyle…Medela AG · 2015
  7. 1 generation backK181863 Elvie PumpChiaro Technology Limited · 2018
  8. This deviceK202037 imani i2Imani Co. · 2021
  9. Descendant · cites it directly · 1 of its ownK220926 Spectra WearableUzinmedicare Co., Ltd. · 2022
  10. Descendant · 2 generations on · 0 of its ownK250208 SPECTRA Wearable 2Uzinmedicare Co., Ltd. · 2026

Most influential descendants

Showing 2 of 2 · See all
  • K220926Spectra WearableUzinmedicare Co., Ltd. · 2022 · cites it directly1descendant
  • K250208SPECTRA Wearable 2Uzinmedicare Co., Ltd. · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K801862Medela Electric Breast PumpMedela, Inc.19801
−6K020518Medela Symphony Breast Pump, Model 024Medela, Inc.20023
−5K053052Medela Swing Breast PumpMedela AG2006—
−4K092783DEBPEnko, Ltd.2009—
−3K122474Lansinoh Powered Electric Breast PumpLansinoh Laboratories Saglik Gerecleri Tasarim San2012—
−2K150499Freestyle Deluxe, Freestyle Solution Set, Freestyle Basic, Freestyle Motor…Medela AG2015—
−1K181863Elvie PumpChiaro Technology Limited2018—
0 (this device)K202037imani i2Imani Co.2021—
+1K220926Spectra WearableUzinmedicare Co., Ltd.2022—
+2K250208SPECTRA Wearable 2Uzinmedicare Co., Ltd.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
199010
199510
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202610
FIG. 1 — Lineage of K202037, 1980–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HGX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HGX device

  1. #1 K212180 Wearable Breast Pump (Model S12)score 34.9 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K181863Elvie Pump
Summary page 4
…on Class Class II Product Code HGX (Pump, Breast, Powered) 3. Predicate Device Information • 510(k) Number: K181863 • Trade/Device Name: Elvie Pump The predicate device has not been subject to a design-related recall. === Pa…
Chiaro Technology Limited2018—

Also cleared against K181863: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K220926Spectra WearableUzinmedicare Co., Ltd.20221

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 41 years and passes through 6 companies; a new generation was cleared every 3.5 years on median.
  • 4 of the 11 ancestors have a recall of any class.
  • Of its descendants, K220926 (Uzinmedicare Co., Ltd., 2022) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K181863.

How does its category compare?

All HGX devices

HGX Pump, Breast, Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · HGX

34so far in 2026, the most since 2007

2007: 12008: 22009: 42010: 72011: 22012: 62013: 42014: 32015: 92016: 72017: 82018: 62019: 72020: 92021: 122022: 152023: 152024: 192025: 262026 (partial year): 34
2007high 34 (2026) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HGX

122in 2025

2009: 121 days median2010: 103 days median2012: 180 days median2013: 131 days median2014: 120 days median2015: 141 days median2016: 121 days median2017: 159 days median2018: 136 days median2019: 158 days median2020: 128 days median2021: 240 days median2022: 190 days median2023: 167 days median2024: 168 days median2025: 122 days median2026 (partial year): 142 days median
2007high 240 (2021) · low 103 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HGX

1in 2017

2010: 52011: 12017: 1
2007high 5 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HGX

69in 2025

2007: 22008: 22010: 882011: 2402012: 6852013: 8372014: 1,0362015: 4962016: 3732017: 4372018: 2912019: 1682020: 1682021: 1192022: 1542023: 2002024: 1182025: 69
2007high 1,036 (2014) · low 0 (2009)2025

MAUDE reports naming product code HGX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—02
20082—02
2009412100
20107103588
20112—1240
201261800685
201341310837
2014312001,036
201591410496
201671210373
201781591437
201861360291
201971580168
202091280168
2021122400119
2022151900154
2023151670200
2024191680118
202526122069
2026341420—

What is it indicated for?

The imani i2 breast pump is a powered breast pump to be used by lactating women to express and collect milk from their breasts. The imani i2 breast pump is a single user device.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K202037: imani i2.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K202037

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026