510(k) · Cleared
ClearedTracheal Stent System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Micro-Tech (Nanjing) Co., Ltd. · JCT Prosthesis, Tracheal, Expandable
Cleared on Sep 1, 2021 as substantially equivalent to K082284 (Alveolus, Inc., 2008) after a 392-day review. Its family tree reaches back 6 generations to 2001. 1 later device descends from it.
- Decided
- Sep 1, 2021
- Review
- 392 days
- Class
- Class II
- Product code
- JCT
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 6 generations to K003173 (2001). 11 ancestors in all, the oldest K894380 (1989). 1 later device descends from it, 1 citing it directly.
- Root · 6 generations backK003173 Aspire Covered Stent and Delivery CatheterVascular Architects, Inc. · 2001
- 5 generations backK012544 Vascular Architects Aspire Covered Stent and Controlled Expansion…Vascular Architects, Inc. · 2001
- 4 generations backK030947 Alveolus Inc., TB-STS Tracheobronchial Stent SystemAlveolus, Inc. · 2003
- 3 generations backK033053 Alveolus, TB-STS Tracheobronchial Stent SystemAlveolus, Inc. · 2004
- 2 generations backK062511 Aero Tracheobronchial Stent System, Model 90129-2XXAlveolus, Inc. · 2007
- 1 generation backK082284 Aero Tracheobronchial Stent Technology SystemAlveolus, Inc. · 2008
- This deviceK202204 Tracheal Stent SystemMicro-Tech (Nanjing) Co., Ltd. · 2021
- Descendant · cites it directly · 0 of its ownK220424 Through the Scope Tracheal Stent SystemMicro-Tech (Nanjing) Co., Ltd. · 2022
Most influential descendants
Showing 1 of 1 · See all- K220424Through the Scope Tracheal Stent SystemMicro-Tech (Nanjing) Co., Ltd. · 2022 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K003173 | Aspire Covered Stent and Delivery Catheter | Vascular Architects, Inc. | 2001 | — |
| −5 | K012544 | Vascular Architects Aspire Covered Stent and Controlled Expansion Delivery… | Vascular Architects, Inc. | 2001 | — |
| −4 | K030947 | Alveolus Inc., TB-STS Tracheobronchial Stent System | Alveolus, Inc. | 2003 | — |
| −3 | K033053 | Alveolus, TB-STS Tracheobronchial Stent System | Alveolus, Inc. | 2004 | — |
| −2 | K062511 | Aero Tracheobronchial Stent System, Model 90129-2XX | Alveolus, Inc. | 2007 | — |
| −1 | K082284 | Aero Tracheobronchial Stent Technology System | Alveolus, Inc. | 2008 | — |
| 0 (this device) | K202204 | Tracheal Stent System | Micro-Tech (Nanjing) Co., Ltd. | 2021 | — |
| +1 | K220424 | Through the Scope Tracheal Stent System | Micro-Tech (Nanjing) Co., Ltd. | 2022 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1989 | 1 | 0 |
| 1996 | 1 | 0 |
| 1997 | 1 | 0 |
| 2001 | 1 | 0 |
| 2004 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2022 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JCT device
- #1 K230269 Ultraflex™ Tracheobronchial Stent Systemscore 8.1 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K082284 | Aero Tracheobronchial Stent Technology SystemSummary page 5….3720 Review Panel: Anesthesiology 1 of 8 4. Identification of Predicate Device 510(k) Number: K082284 Product Name: AERO™ Tracheobronchial Stent Technology System Manufacturer: Merit Medical Systems, Inc. 5. Indications… | 2008 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K220424 | Through the Scope Tracheal Stent System | 2022 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 1.8 years on median.
- None of the 11 ancestors has a recall.
- Of its descendants, K220424 (Micro-Tech (Nanjing) Co., Ltd., 2022) has gone furthest, with 0 descendants of its own.
- 4 other devices also cite its predicate K082284.
How does its category compare?
All JCT devicesJCT Prosthesis, Tracheal, Expandable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · JCT
1in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · JCT
234in 2014
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JCT
2in 2011
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JCT
50in 2025
MAUDE reports naming product code JCT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 150 |
| 2008 | 1 | — | 0 | 143 |
| 2009 | 1 | — | 0 | 163 |
| 2010 | 0 | — | 46 | 147 |
| 2011 | 0 | — | 2 | 95 |
| 2012 | 1 | — | 0 | 109 |
| 2013 | 0 | — | 0 | 238 |
| 2014 | 3 | 234 | 0 | 168 |
| 2015 | 0 | — | 0 | 251 |
| 2016 | 1 | — | 0 | 217 |
| 2017 | 0 | — | 0 | 109 |
| 2018 | 1 | — | 0 | 122 |
| 2019 | 0 | — | 0 | 106 |
| 2020 | 1 | — | 0 | 120 |
| 2021 | 2 | — | 0 | 106 |
| 2022 | 1 | — | 0 | 61 |
| 2023 | 1 | — | 0 | 110 |
| 2024 | 0 | — | 0 | 74 |
| 2025 | 0 | — | 0 | 50 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Tracheal Stent System (OTW) is indicated for use in the treatment of tracheobronchial strictures caused by malignant neoplasms.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K202204 · printed Nov 6, 2026
Cite this page
510(k) Report. “K202204: Tracheal Stent System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K202204