510(k) · Cleared
ClearedCrossRoads Tray System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Crossroads Extremity Systems, LLC · KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories
Cleared on Dec 30, 2020 as substantially equivalent to K200632 (THINK Surgical, Inc., 2020) after a 141-day review. Its family tree reaches back 8 generations to 1984. 3 later devices descend from it.
- Decided
- Dec 30, 2020
- Review
- 141 days
- Class
- Class II
- Product code
- KCT
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 8 generations to K844002 (1984). 12 ancestors in all. 3 later devices descend from it, 2 citing it directly.
- Root · 8 generations backK844002 HU-Friedy Ims Cassette SystemHu-Friedy Mfg. Co., Inc. · 1984
- 7 generations backK980065 C/T Med-Systems Cassette SystemC/T Med System, Ltd. · 1998
- 6 generations backK990761 Tuttnauer Mini Container Cassette, Tuttnauer Standard Case CassetteTuttnauer U.S.A Co, Ltd. · 1999
- 5 generations backK012105 Polyvac Surgical Instrument Delivery SystemSymmetry Medical, Inc. · 2002
- 4 generations backK032119 Paragon Medical Surgical Instrument Delivery System VariousParagon Medical, Inc. · 2003
- 3 generations backK072211 Intuitive Surgical Instrument and Accessories Sterilization TraysIntuitive Surgical, Inc. · 2008
- 2 generations backK180127 TCAT (R) THA Instrument Tray SetTHINK Surgical, Inc. · 2019
- 1 generation backK200632 TCAT TKA Instrument Tray SetTHINK Surgical, Inc. · 2020
- This deviceK202268 CrossRoads Tray SystemCrossroads Extremity Systems, LLC · 2020
- Descendant · cites it directly · 1 of its ownK241927 Synthes Graphic Case & Tray SystemSynthes GmbH · 2025
- Descendant · 2 generations on · 0 of its ownK253791 PUREVUE™ Quick Connect Cannula System Tray; PUREVUE™ Quick Connect…DePuy Mitek, Inc. · 2026
- Descendant · cites it directly · 0 of its ownK241050 CrossRoads Modular Tray SystemCrossroads Extremity Systems · 2024
Most influential descendants
Showing 3 of 3 · See all- K241927Synthes Graphic Case & Tray SystemSynthes GmbH · 2025 · cites it directly1descendant
- K253791PUREVUE™ Quick Connect Cannula System Tray; PUREVUE™ Quick Connect Cannula System LidDePuy Mitek, Inc. · 2026 · 2 generations on0descendants
- K241050CrossRoads Modular Tray SystemCrossroads Extremity Systems · 2024 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −8 | K844002 | HU-Friedy Ims Cassette System | Hu-Friedy Mfg. Co., Inc. | 1984 | — |
| −7 | K980065 | C/T Med-Systems Cassette System | C/T Med System, Ltd. | 1998 | — |
| −6 | K990761 | Tuttnauer Mini Container Cassette, Tuttnauer Standard Case Cassette | Tuttnauer U.S.A Co, Ltd. | 1999 | — |
| −5 | K012105 | Polyvac Surgical Instrument Delivery System | Symmetry Medical, Inc. | 2002 | — |
| −4 | K032119 | Paragon Medical Surgical Instrument Delivery System Various | Paragon Medical, Inc. | 2003 | — |
| −3 | K072211 | Intuitive Surgical Instrument and Accessories Sterilization Trays | Intuitive Surgical, Inc. | 2008 | — |
| −2 | K180127 | TCAT (R) THA Instrument Tray Set | THINK Surgical, Inc. | 2019 | — |
| −1 | K200632 | TCAT TKA Instrument Tray Set | THINK Surgical, Inc. | 2020 | — |
| 0 (this device) | K202268 | CrossRoads Tray System | Crossroads Extremity Systems, LLC | 2020 | — |
| +1 | K241927 | Synthes Graphic Case & Tray System | Synthes GmbH | 2025 | — |
| +2 | K253791 | PUREVUE™ Quick Connect Cannula System Tray; PUREVUE™ Quick Connect Cannula… | DePuy Mitek, Inc. | 2026 | — |
| +1 | K241050 | CrossRoads Modular Tray System | Crossroads Extremity Systems | 2024 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1997 | 1 | 0 |
| 2001 | 1 | 0 |
| 2004 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2024 | 1 | 0 |
| 2025 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KCT device
- #1 K214041 Aesculap AICON Containerscore 18.1 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K200632 | TCAT TKA Instrument Tray SetSummary page 4…ion Wrap Containers, Trays, Cassettes & other Accessories Panel: General Hospital Product Code: KCT Predicate Devices: K200632 TCAT TKA Instrument Tray Set Device Description: The subject CrossRoads Tray System is a reusable steril… | 2020 |
What descends from it? (3)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 36 years and passes through 8 companies; a new generation was cleared every 3.1 years on median.
- None of the 12 ancestors has a recall.
- Of its descendants, K241927 (Synthes GmbH, 2025) has gone furthest, with 1 descendant of its own.
- 1 other device also cites its predicate K200632.
How does its category compare?
All KCT devicesKCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · KCT
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KCT
205in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KCT
17in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KCT
50in 2025
MAUDE reports naming product code KCT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 199 | 0 | 2 |
| 2008 | 6 | 182 | 0 | 8 |
| 2009 | 6 | 89 | 0 | 5 |
| 2010 | 12 | 202 | 1 | 3 |
| 2011 | 6 | 117 | 2 | 3 |
| 2012 | 10 | 236 | 0 | 2 |
| 2013 | 8 | 131 | 1 | 6 |
| 2014 | 11 | 169 | 1 | 5 |
| 2015 | 15 | 151 | 0 | 6 |
| 2016 | 12 | 182 | 3 | 16 |
| 2017 | 10 | 211 | 1 | 3 |
| 2018 | 15 | 192 | 0 | 22 |
| 2019 | 18 | 187 | 0 | 15 |
| 2020 | 14 | 134 | 0 | 66 |
| 2021 | 18 | 185 | 1 | 26 |
| 2022 | 11 | 137 | 17 | 8 |
| 2023 | 10 | 94 | 0 | 30 |
| 2024 | 8 | 106 | 0 | 18 |
| 2025 | 11 | 205 | 0 | 50 |
| 2026 | 9 | 122 | 0 | — |
What is it indicated for?
The CrossRoads Tray System is used in healthcare facilities to store and organize CrossRoads surgical instruments and components during cleaning/sterilization and during implant/prosthetic treatment. The CrossRoads Tray System are not intended on their own to maintain sterility; it is intended to be used in conjunction with a legally marketed, validated, FDA-cleared sterilization pouch or sterilization wrap. Sterilization validations for the worst-case…
Read the full statement (126 words)
The CrossRoads Tray System is used in healthcare facilities to store and organize CrossRoads surgical instruments and components during cleaning/sterilization and during implant/prosthetic treatment. The CrossRoads Tray System are not intended on their own to maintain sterility; it is intended to be used in conjunction with a legally marketed, validated, FDA-cleared sterilization pouch or sterilization wrap. Sterilization validations for the worst-case CrossRoads Tray System included surgical instruments such as drills, inserters, reamers, fixation pin, benders, and ratcheting handles. The CrossRoads Tray System were validated for a maximum load of 8.5 lbs (tray + instruments).
Method: Steam Sterilization (Moist Heat Sterilization) Cycle Prevacuum
Temperature: 270 ˚F (132 ˚C)
Exposure time: 4 minutes
Drying time: 20 minutes
The tray is 20.60” length x 9.80” width x 2.00” depth.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K202268 · printed Nov 4, 2026
Cite this page
510(k) Report. “K202268: CrossRoads Tray System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K202268
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026