PRE-MILLED Abutment

K202269510(k) TraditionalCleared Nov 25, 2020106-day reviewClass II21 CFR 872.3630

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mit Global Co., Ltd. · NHA Abutment, Implant, Dental, Endosseous

Cleared on Nov 25, 2020 as substantially equivalent to K150203 (Medentika GmbH, 2015) after a 106-day review. Its family tree reaches back 14 generations to 1990.

Decided
Nov 25, 2020
Review
106 days
Class
Class II
Product code
NHA
Recalls
None
Predicates
1

Its longest line of descent runs back 14 generations to K894844 (1990). 171 ancestors in all, the oldest K871863 (1987). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2011: 2 other ancestors2010: 1 other ancestor2009: 4 other ancestors2008: 6 other ancestors2007: 11 other ancestors2006: 13 other ancestors2005: 8 other ancestors2004: 9 other ancestors2003: 8 other ancestors2002: 12 other ancestors2001: 9 other ancestors2000: 6 other ancestors1997: 4 other ancestors1996: 13 other ancestors1994: 11 other ancestors1999: 7 other ancestors1998: 7 other ancestors1995: 8 other ancestors1993: 12 other ancestors1992: 1 other ancestor1990: 2 other ancestors1989: 1 other ancestor1987: 1 other ancestor1991: 1 other ancestorReference device: K142082 · Zimmer 3.1MM Dental Implant;2.9MM Angled Abutment;Straight Hex, 2.9MM Contour Abutement · Zimmer Dental, Inc. · 2014Reference device: K013227 · Screw Vent Implant; Tapered Screw Vent Implant · Sulzer Dental, Inc. · 2001 · recalledK894844 · Bonefit Implant System Accessories & Instruments · Straumann Institute, Ltd. · 1990K990342 · Synocta Prosthetics · Straumann USA · 1999×2: 2 generations cleared close together, K013798 (2001), K020096 (2002) K033243 · Iti Synocta Meso Abutments · Straumann USA · 2003K052272 · Straumann Computer Aided Restoration Service · Straumann USA · 2006K061277 · Straumann Computer Aided Restoration Service (C.a.R.E.S.) Ceramic Coping · Straumann USA · 2007K072151 · P.004 RC Cares Titanium and Ceramic Abutments · Straumann USA · 2007 · recalledK081005 · P.004 NC Cares Titanium and Ceramic Abutments · Institut Straumann AG · 2008 · recalledK082545 · Straumann NN Cares Titanium and Ceramic Abutments · Institut Straumann AG · 2008K093113 · Etkon ES1, Model 019.0001, Etkon Visual, Straumann Cadcam Abutment · Institut Straumann AG · 2009K101465 · Straumann Cares Bridge; Straumann Cares Dolder Bar · Institut Straumann AG · 2010K120822 · Straumann Cares Variobase Abutment NNC, Straumann Cares Variobase Abutment RN, Straumann Cares Variobase Abutment WN, ST · Institut Straumann AG · 2012K150203 · Medentika CAD/CAM Abutments · Medentika GmbH · 20151990200020102020
Other ancestors, by generation 3 generations back: 8 other ancestors4 generations back: 25 other ancestors5 generations back: 24 other ancestors6 generations back: 27 other ancestors7 generations back: 43 other ancestors8 generations back: 17 other ancestors9 generations back: 8 other ancestors10 generations back: 2 other ancestors11 generations back: 2 other ancestors12 generations back: 1 other ancestor K150203 · Medentika CAD/CAM Abutments · Medentika GmbH · 2015K120822 · Straumann Cares Variobase Abutment NNC, Straumann Cares Variobase Abutment RN, Straumann Cares Variobase Abutment WN, ST · Institut Straumann AG · 2012K101465 · Straumann Cares Bridge; Straumann Cares Dolder Bar · Institut Straumann AG · 2010K093113 · Etkon ES1, Model 019.0001, Etkon Visual, Straumann Cadcam Abutment · Institut Straumann AG · 2009K082545 · Straumann NN Cares Titanium and Ceramic Abutments · Institut Straumann AG · 2008K081005 · P.004 NC Cares Titanium and Ceramic Abutments · Institut Straumann AG · 2008 · recalledK072151 · P.004 RC Cares Titanium and Ceramic Abutments · Straumann USA · 2007 · recalledK061277 · Straumann Computer Aided Restoration Service (C.a.R.E.S.) Ceramic Coping · Straumann USA · 2007K052272 · Straumann Computer Aided Restoration Service · Straumann USA · 2006K033243 · Iti Synocta Meso Abutments · Straumann USA · 2003K020096 · Esthetic Ease Abutments for the Iti Dental Implant System · Institut Straumann AG · 2002 · recalledK013798 · Prosthetic Accessories to the Iti Dental Implant System · Institut Straumann AG · 2001K990342 · Synocta Prosthetics · Straumann USA · 1999K894844 · Bonefit Implant System Accessories & Instruments · Straumann Institute, Ltd. · 1990−10−50
  1. Root · 14 generations backK894844 Bonefit Implant System Accessories & InstrumentsStraumann Institute, Ltd. · 1990
  2. 10 generations between
  3. 3 generations backK101465 Straumann Cares Bridge; Straumann Cares Dolder BarInstitut Straumann AG · 2010
  4. 2 generations backK120822 Straumann Cares Variobase Abutment NNC, Straumann Cares Variobase…Institut Straumann AG · 2012
  5. 1 generation backK150203 Medentika CAD/CAM AbutmentsMedentika GmbH · 2015
  6. This deviceK202269 PRE-MILLED AbutmentMit Global Co., Ltd. · 2020
Show all 14 generations
  1. Root · 14 generations backK894844 Bonefit Implant System Accessories & InstrumentsStraumann Institute, Ltd. · 1990
  2. 13 generations backK990342 Synocta ProstheticsStraumann USA · 1999
  3. 12 generations backK013798 Prosthetic Accessories to the Iti Dental Implant SystemInstitut Straumann AG · 2001
  4. 11 generations backK020096 Esthetic Ease Abutments for the Iti Dental Implant SystemInstitut Straumann AG · 2002 · Recalled
  5. 10 generations backK033243 Iti Synocta Meso AbutmentsStraumann USA · 2003
  6. 9 generations backK052272 Straumann Computer Aided Restoration ServiceStraumann USA · 2006
  7. 8 generations backK061277 Straumann Computer Aided Restoration Service (C.a.R.E.S.) Ceramic…Straumann USA · 2007
  8. 7 generations backK072151 P.004 RC Cares Titanium and Ceramic AbutmentsStraumann USA · 2007 · Recalled
  9. 6 generations backK081005 P.004 NC Cares Titanium and Ceramic AbutmentsInstitut Straumann AG · 2008 · Recalled
  10. 5 generations backK082545 Straumann NN Cares Titanium and Ceramic AbutmentsInstitut Straumann AG · 2008
  11. 4 generations backK093113 Etkon ES1, Model 019.0001, Etkon Visual, Straumann Cadcam AbutmentInstitut Straumann AG · 2009
  12. 3 generations backK101465 Straumann Cares Bridge; Straumann Cares Dolder BarInstitut Straumann AG · 2010
  13. 2 generations backK120822 Straumann Cares Variobase Abutment NNC, Straumann Cares Variobase…Institut Straumann AG · 2012
  14. 1 generation backK150203 Medentika CAD/CAM AbutmentsMedentika GmbH · 2015
  15. This deviceK202269 PRE-MILLED AbutmentMit Global Co., Ltd. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−14K894844Bonefit Implant System Accessories & InstrumentsStraumann Institute, Ltd.1990—
−13K990342Synocta ProstheticsStraumann USA1999—
−12K013798Prosthetic Accessories to the Iti Dental Implant SystemInstitut Straumann AG2001—
−11K020096Esthetic Ease Abutments for the Iti Dental Implant SystemInstitut Straumann AG20021
−10K033243Iti Synocta Meso AbutmentsStraumann USA2003—
−9K052272Straumann Computer Aided Restoration ServiceStraumann USA2006—
−8K061277Straumann Computer Aided Restoration Service (C.a.R.E.S.) Ceramic CopingStraumann USA2007—
−7K072151P.004 RC Cares Titanium and Ceramic AbutmentsStraumann USA20071
−6K081005P.004 NC Cares Titanium and Ceramic AbutmentsInstitut Straumann AG20081
−5K082545Straumann NN Cares Titanium and Ceramic AbutmentsInstitut Straumann AG2008—
−4K093113Etkon ES1, Model 019.0001, Etkon Visual, Straumann Cadcam AbutmentInstitut Straumann AG2009—
−3K101465Straumann Cares Bridge; Straumann Cares Dolder BarInstitut Straumann AG2010—
−2K120822Straumann Cares Variobase Abutment NNC, Straumann Cares Variobase Abutment RN…Institut Straumann AG2012—
−1K150203Medentika CAD/CAM AbutmentsMedentika GmbH2015—
0 (this device)K202269PRE-MILLED AbutmentMit Global Co., Ltd.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198910
199020
199110
199210
1993120
1994110
199580
1996130
199740
199870
199970
200060
200190
2002120
200380
200490
200580
2006130
2007110
200860
200940
201010
201120
FIG. 1 — Lineage of K202269, 1990–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NHA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NHA device

  1. #1 K222288 DESS Dental Smart Solutionsscore 30.7 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K150203Medentika CAD/CAM Abutments
Summary page 4
…I Primary Predicate Trade Name: Medentika CAD/CAM Abutment (K150203) Common Name: Endosseous dent…
Medentika GmbH2015—
†K142082Zimmer 3.1MM Dental Implant;2.9MM Angled Abutment;Straight Hex, 2.9MM Contour AbutementZimmer Dental, Inc.2014—
†K013227Screw Vent Implant; Tapered Screw Vent ImplantSulzer Dental, Inc.20012

Also cleared against K150203: 13 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 5 companies; a new generation was cleared every 1.7 years on median.
  • 18 of the 171 ancestors have a recall of any class.
  • 13 other devices also cite its predicate K150203.

How does its category compare?

All NHA devices

NHA Abutment, Implant, Dental, Endosseous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · NHA

40in 2025

2007: 382008: 312009: 302010: 192011: 312012: 252013: 222014: 272015: 292016: 382017: 312018: 312019: 282020: 382021: 292022: 332023: 512024: 432025: 402026 (partial year): 23
2007high 51 (2023) · low 19 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NHA

147in 2025

2007: 91 days median2008: 90 days median2009: 95 days median2010: 162 days median2011: 130 days median2012: 171 days median2013: 184 days median2014: 160 days median2015: 151 days median2016: 202 days median2017: 188 days median2018: 200 days median2019: 160 days median2020: 153 days median2021: 211 days median2022: 142 days median2023: 147 days median2024: 158 days median2025: 147 days median2026 (partial year): 169 days median
2007high 211 (2021) · low 90 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NHA

1in 2025

2007: 12008: 22011: 52012: 12013: 12015: 12016: 362017: 22018: 12020: 72023: 32025: 12026 (partial year): 3
2007high 36 (2016) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NHA

838in 2025

2007: 12008: 82009: 302010: 612011: 562012: 52013: 1432014: 1462015: 8582016: 3142017: 5772018: 5912019: 5302020: 4582021: 5462022: 4972023: 6182024: 6352025: 838
2007high 858 (2015) · low 1 (2007)2025

MAUDE reports naming product code NHA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007389111
2008319028
20093095030
201019162061
201131130556
20122517115
2013221841143
2014271600146
2015291511858
20163820236314
2017311882577
2018312001591
2019281600530
2020381537458
2021292110546
2022331420497
2023511473618
2024431580635
2025401471838
2026231693—

What is it indicated for?

The PRE-MILLED Abutments are intended for use with dental implants as a support for single or multiple tooth prostheses in the maxilla or mandible of a partially or fully edentulous patient. It is compatible with the following systems: • Zimmer 3.1mmD Dental Implant System (K142082) • Screw Vent® and Tapered Screw Vent® (K013227) All digitally designed abutments for use with the PRE-MILLED Abutments must be designed and milled through the 3Shape CAD/CAM…

Read the full statement (163 words)

The PRE-MILLED Abutments are intended for use with dental implants as a support for single or multiple tooth prostheses in the maxilla or mandible of a partially or fully edentulous patient.

It is compatible with the following systems:

• Zimmer 3.1mmD Dental Implant System (K142082)

• Screw Vent® and Tapered Screw Vent® (K013227)

All digitally designed abutments for use with the PRE-MILLED Abutments must be designed and milled through the 3Shape CAD/CAM System and are intended to be sent to a validated milling center for manufacture.

The PRE-MILLED Abutment is compatible with the following devices:

Zimmer 3.1mmD Dental Implant System (K142082)

Implant Body Diameter 3.1/ Implant Platform Diameter 2.9 / Internal Hex

Screw Vent® and Tapered Screw Vent® (K013227)

Implant Body Diameter 3.7/ Implant Platform Diameter 3.5 / Internal Hex

Implant Body Diameter 4.1/ Implant Platform Diameter 3.5 / Internal Hex

Implant Body Diameter 4.7/ Implant Platform Diameter 4.5 / Internal Hex

Implant Body Diameter 6.0/ Implant Platform Diameter 5.7 / Internal Hex

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K202269: PRE-MILLED Abutment.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K202269

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026