510(k) Report

510(k) · Cleared

Cleared

BoneMRI

K202404510(k) TraditionalCleared Dec 22, 2021488-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mriguidance B.V. · QIH Automated Radiological Image Processing Software

Cleared on Dec 22, 2021 as substantially equivalent to K191688 (Subtle Medical, Inc., 2019) after a 488-day review. Its family tree reaches back 5 generations to 1992. 5 later devices descend from it.

Decided
Dec 22, 2021
Review
488 days
Class
Class II
Product code
QIH
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K922470 (1992). 5 later devices descend from it, 1 citing it directly.

Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 1 descendant4 generations forward: 2 descendants K191688 · SubtleMR · Subtle Medical, Inc. · 2019K172768 · ZOOM · Zetta Medical Technologies, LLC · 2018K024028 · Sharp View Image Enhancement System · Context Vision AB · 2003K993802 · Sharpview Image Enhancement System · Context Vision AB · 2000K922470 · Ies, Image Enhancement System · Open Mri, Inc. · 1992−50
  1. Root · 5 generations backK922470 Ies, Image Enhancement SystemOpen Mri, Inc. · 1992
  2. 4 generations backK993802 Sharpview Image Enhancement SystemContext Vision AB · 2000
  3. 3 generations backK024028 Sharp View Image Enhancement SystemContext Vision AB · 2003
  4. 2 generations backK172768 ZOOMZetta Medical Technologies, LLC · 2018
  5. 1 generation backK191688 SubtleMRSubtle Medical, Inc. · 2019
  6. This deviceK202404 BoneMRIMriguidance B.V. · 2021
  7. Descendant · cites it directly · 4 of its ownK221762 BoneMRI v1.4Mrlguidance B.V. · 2022
  8. Descendant · 2 generations on · 3 of its ownK230197 BoneMRI v1.6Mriguidance B.V. · 2023
  9. Descendant · 3 generations on · 2 of its ownK233030 BoneMRIMriguidance B.V. · 2024
  10. Descendant · 4 generations on · 0 of its ownK260525 NextMR SpineMRI2CT, Inc. · 2026
  11. Descendant · 4 generations on · 0 of its ownK260584 BoneMRIMriguidance B.V. · 2026

Most influential descendants

Showing 5 of 5 · See all
  • K221762BoneMRI v1.4Mrlguidance B.V. · 2022 · cites it directly4descendants
  • K230197BoneMRI v1.6Mriguidance B.V. · 2023 · 2 generations on3descendants
  • K233030BoneMRIMriguidance B.V. · 2024 · 3 generations on2descendants
  • K260525NextMR SpineMRI2CT, Inc. · 2026 · 4 generations on0descendants
  • K260584BoneMRIMriguidance B.V. · 2026 · 4 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K922470Ies, Image Enhancement SystemOpen Mri, Inc.1992—
−4K993802Sharpview Image Enhancement SystemContext Vision AB2000—
−3K024028Sharp View Image Enhancement SystemContext Vision AB2003—
−2K172768ZOOMZetta Medical Technologies, LLC2018—
−1K191688SubtleMRSubtle Medical, Inc.2019—
0 (this device)K202404BoneMRIMriguidance B.V.2021—
+1K221762BoneMRI v1.4Mrlguidance B.V.2022—
+2K230197BoneMRI v1.6Mriguidance B.V.2023—
+3K233030BoneMRIMriguidance B.V.2024—
+4K260525NextMR SpineMRI2CT, Inc.2026—
+4K260584BoneMRIMriguidance B.V.2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202310
202410
202620
FIG. 1 — Lineage of K202404, 1992–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QIH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QIH device

  1. #1 K213998 cvi42 Auto Imaging Software Applicationscore 23.5 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K191688SubtleMR
Summary page 5
…Name Manufacturer 510(k)# SubtleMR Subtle Medical, Inc. K191688 This predicate has not been subject to a design-related recall. No reference devices were used in this submission. IV.…
Subtle Medical, Inc.2019—

Also cleared against K191688: 3 other devices →

What descends from it? (5)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K221762BoneMRI v1.4Mrlguidance B.V.20224

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 5 companies; a new generation was cleared every 3.0 years on median.
  • None of the 5 ancestors has a recall.
  • Of its descendants, K221762 (Mrlguidance B.V., 2022) has gone furthest, with 4 descendants of its own.
  • 3 other devices also cite its predicate K191688.

How does its category compare?

All QIH devices

QIH Automated Radiological Image Processing Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · QIH

94in 2025

2019: 22020: 112021: 192022: 252023: 452024: 642025: 942026 (partial year): 78
2007high 94 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QIH

150in 2025

2020: 145 days median2021: 125 days median2022: 134 days median2023: 151 days median2024: 141 days median2025: 150 days median2026 (partial year): 130 days median
2007high 151 (2023) · low 125 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QIH

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QIH

4in 2025

2024: 22025: 4
2007high 4 (2025) · low 0 (2007)2025

MAUDE reports naming product code QIH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20192—00
20201114500
20211912500
20222513400
20234515100
20246414102
20259415004
2026781301—

What is it indicated for?

BoneMRI is an image processing software that can be used for image enhancement in MRI images. It can be used to visualize the bone structures in MRI images with enhanced contrast with respect to the surrounding soft tissue. It is to be used in the pelvic region, which includes the boney anatomy of the sacrum, hip bones and femoral heads.

Warning: BoneMRI images are not intended to replace CT images and are not to be used for diagnosis or monitoring of (primary or metastatic) tumors.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K202404: BoneMRI.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K202404

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026