510(k) · Cleared
Recalled · Class II · 2025Nutriglide (TM) Nasal Feeding Tube
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Applied Medical Technology, Inc. · KNT Tubes, Gastrointestinal (And Accessories)
Cleared on Oct 29, 2020 as substantially equivalent to K821906 (Corpak Medsystems, 1982) and 1 other predicate after a 57-day review. Its family tree reaches back 1 generation to 1982. 1 later device descends from it. It has been recalled 6 times.
- Decided
- Oct 29, 2020
- Review
- 57 days
- Class
- Class II
- Product code
- KNT
- Recalls
- 6
- Predicates
- 2
Its longest line of descent runs back 1 generation to K821906 (1982). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 1 generation backK821906 Corpak Enteric Feeding Tube W/Guide TipCorpak Medsystems · 1982 · Recalled
- This deviceK202539 Nutriglide (TM) Nasal Feeding TubeApplied Medical Technology, Inc. · 2020
- Descendant · cites it directly · 0 of its ownK241169 Entarik NI Feeding Tube SystemGravitas Medical, Inc. · 2024
Most influential descendants
Showing 1 of 1 · See all- K241169Entarik NI Feeding Tube SystemGravitas Medical, Inc. · 2024 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K821906 | Corpak Enteric Feeding Tube W/Guide Tip | Corpak Medsystems | 1982 | 1 |
| 0 (this device) | K202539 | Nutriglide (TM) Nasal Feeding Tube | Applied Medical Technology, Inc. | 2020 | — |
| +1 | K241169 | Entarik NI Feeding Tube System | Gravitas Medical, Inc. | 2024 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1983 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KNT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KNT device
- #1 K261890 52Fr ViSiGi LUX™; 52Fr ViSiGi 3D®score 12.7 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K821906 | Corpak Enteric Feeding Tube W/Guide TipSummary page 4…mber: 21 CFR 876.5980 Regulation Name: Gastrointestinal tube and accessories Regulatory Class: II Product Code: KNT III. PREDICATE INFORMATION: Predicate Devices: K821906 Corpak enteric feeding tube w/guide tip; Corpak Medsystems K831328 Neonatal Nasogastric feeding tube, Corpak Enteric Feeding… | 1982 |
| * | K831328 | Neonatal Nasogastric Feeding Tube-Summary page 4…ries Regulatory Class: II Product Code: KNT III. PREDICATE INFORMATION: Predicate Devices: K821906 Corpak enteric feeding tube w/guide tip; Corpak Medsystems K831328 Neonatal Nasogastric feeding tube, Corpak Enteric Feeding Tube w/Guide Tip; Corpak Medsystems **These predicate devices h… | 1983 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K241169 | Entarik NI Feeding Tube System | 2024 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Oct 6, 2025 | Class II | Z-0498-2026 | Process control | The nasal feeding tube may be occluded |
| Oct 6, 2025 | Class II | Z-0496-2026 | Process control | The nasal feeding tube may be occluded |
| Oct 6, 2025 | Class II | Z-0497-2026 | Process control | The nasal feeding tube may be occluded |
| Oct 6, 2025 | Class II | Z-0494-2026 | Process control | The nasal feeding tube may be occluded |
| Oct 6, 2025 | Class II | Z-0495-2026 | Process control | The nasal feeding tube may be occluded |
| Aug 12, 2025 | Class II | Z-0127-2026 | Process control | The nasal feeding tubes, NutraGlide, subject to this recall have distal tips that may detach at lower than expected forces. |
The 5 latest of 6 recalls; the web page lists all.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All KNT devicesKNT Tubes, Gastrointestinal (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · KNT
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KNT
136in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KNT
13in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · KNT
1,451in 2025
MAUDE reports naming product code KNT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 118 | 1 | 300 |
| 2008 | 10 | 115 | 82 | 867 |
| 2009 | 11 | 102 | 9 | 818 |
| 2010 | 12 | 104 | 3 | 517 |
| 2011 | 7 | 211 | 2 | 531 |
| 2012 | 12 | 107 | 1 | 528 |
| 2013 | 7 | 128 | 0 | 747 |
| 2014 | 16 | 259 | 0 | 1,030 |
| 2015 | 10 | 140 | 1 | 1,048 |
| 2016 | 6 | 99 | 3 | 1,251 |
| 2017 | 9 | 247 | 4 | 1,672 |
| 2018 | 7 | 149 | 2 | 1,901 |
| 2019 | 10 | 126 | 2 | 1,838 |
| 2020 | 5 | 102 | 1 | 1,641 |
| 2021 | 6 | 121 | 2 | 1,655 |
| 2022 | 7 | 110 | 1 (1) | 1,650 |
| 2023 | 5 | 162 | 2 | 1,863 |
| 2024 | 9 | 103 | 0 | 1,344 |
| 2025 | 4 | 136 | 13 | 1,451 |
| 2026 | 3 | 105 | 20 | — |
What is it indicated for?
The NutriGlide™ Nasal Feeding Tube is indicated for the administration of nutrition, fluids, and medications in neonatal, pediatric, and adult patients.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K202539 · printed Nov 6, 2026
Cite this page
510(k) Report. “K202539: Nutriglide (TM) Nasal Feeding Tube.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K202539
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026