510(k) Report

510(k) · Cleared

Cleared

OMNI Surgical System

K202678510(k) TraditionalCleared Mar 1, 2021167-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sight Sciences, Inc. · MRH Pump, Infusion, Ophthalmic

Cleared on Mar 1, 2021 as substantially equivalent to K173332 (Sight Sciences, Inc., 2017) after a 167-day review. Its family tree reaches back 8 generations to 1990. 2 later devices descend from it.

Decided
Mar 1, 2021
Review
167 days
Class
Class II
Product code
MRH
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K902835 (1990). 18 ancestors in all, the oldest K884043 (1988). 2 later devices descend from it, 1 citing it directly.

  1. Root · 8 generations backK902835 FTS-100 Fluid Transfer SystemRichard James, Inc. · 1990
  2. 7 generations backK972664 Storz Millennium Viscous Fluid SystemStorz Instrument Co. · 1997
  3. 6 generations backK993039 Viscous Fluid Injector System Module (CX5700)Bausch & Lomb, Inc. · 2000
  4. 5 generations backK050716 Iscience Surgical ViscoinjectorIscience Surgical Corporation · 2005
  5. 4 generations backK132494 Viscoelastic InjectorSight Sciences, Inc. · 2013
  6. 3 generations backK143205 Viscoelastic InjectorSight Sciences, Inc. · 2014
  7. 2 generations backK171905 VISCO 360 Viscosurgical SystemSight Sciences, Inc. · 2017
  8. 1 generation backK173332 OMNI Surgical SystemSight Sciences, Inc. · 2017
  9. This deviceK202678 OMNI Surgical SystemSight Sciences, Inc. · 2021
  10. Descendant · cites it directly · 1 of its ownK232214 OMNI Surgical SystemSight Sciences, Inc. · 2023
  11. Descendant · 2 generations on · 0 of its ownK253760 OMNI Ultra Surgical System (1-110)Sight Sciences, Inc. · 2026

Most influential descendants

Showing 2 of 2 · See all
  • K232214OMNI Surgical SystemSight Sciences, Inc. · 2023 · cites it directly1descendant
  • K253760OMNI Ultra Surgical System (1-110)Sight Sciences, Inc. · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K902835FTS-100 Fluid Transfer SystemRichard James, Inc.1990—
−7K972664Storz Millennium Viscous Fluid SystemStorz Instrument Co.1997—
−6K993039Viscous Fluid Injector System Module (CX5700)Bausch & Lomb, Inc.2000—
−5K050716Iscience Surgical ViscoinjectorIscience Surgical Corporation2005—
−4K132494Viscoelastic InjectorSight Sciences, Inc.2013—
−3K143205Viscoelastic InjectorSight Sciences, Inc.2014—
−2K171905VISCO 360 Viscosurgical SystemSight Sciences, Inc.2017—
−1K173332OMNI Surgical SystemSight Sciences, Inc.2017—
0 (this device)K202678OMNI Surgical SystemSight Sciences, Inc.2021—
+1K232214OMNI Surgical SystemSight Sciences, Inc.2023—
+2K253760OMNI Ultra Surgical System (1-110)Sight Sciences, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
198910
199630
199720
200110
200410
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202610
FIG. 1 — Lineage of K202678, 1990–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MRH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MRH device

  1. #1 K253760 OMNI Ultra Surgical System (1-110)score 14.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K173332OMNI Surgical System
Summary page 4
…oduct Code: HMZ Primary Predicate Device Device Name: OMNI® Surgical System 510(k) Holder: Sight Sciences, Inc. 510(k) Number: K173332 Clearance Date: December 21, 2017 Reference Device Device Name: iScience Interventional Canaloplasty M…
Sight Sciences, Inc.2017—
†K080067Iscience Interventional Ophthalmic MicrocatheterIscience Interventional20082

Also cleared against K173332: 3 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K232214OMNI Surgical SystemSight Sciences, Inc.20231

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 5 companies; a new generation was cleared every 3.2 years on median.
  • 2 of the 18 ancestors have a recall of any class.
  • Of its descendants, K232214 (Sight Sciences, Inc., 2023) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K173332.

How does its category compare?

All MRH devices

MRH Pump, Infusion, Ophthalmic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · MRH

1in 2025

2013: 12014: 12017: 22020: 12021: 22022: 22023: 12025: 12026 (partial year): 1
2007high 2 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MRH

Too few MRH 510(k)s in any year since 2007 to give a median.

Recalls per year · MRH

No recall names MRH since 2007.

Adverse event reports per year · MRH

14in 2025

2017: 282018: 12019: 22020: 62021: 22022: 162023: 312024: 202025: 14
2007high 31 (2023) · low 0 (2007)2025

MAUDE reports naming product code MRH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20131—00
20141—00
20150—00
20160—00
20172—028
20180—01
20190—02
20201—06
20212—02
20222—016
20231—031
20240—020
20251—014
20261—0—

What is it indicated for?

The OMNI® Surgical System is indicated for canaloplasty (microcatheterization and transluminal viscodilation of Schlemm’s canal) followed by trabeculotomy (cutting of trabecular meshwork) to reduce intraocular pressure in adult patients with primary open-angle glaucoma.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K202678: OMNI Surgical System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K202678

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026