510(k) Report

510(k) · Cleared

Cleared

2430MCA with Xmaru W

K202902510(k) TraditionalCleared Jun 21, 2021265-day reviewClass II21 CFR 892.1715

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rayence Co., Ltd. · MUE Full Field Digital, System, X-Ray, Mammographic

Cleared on Jun 21, 2021 as substantially equivalent to K162670 (DRTECH Corporation, 2017) after a 265-day review. Its family tree reaches back 10 generations to 1990. 1 later device descends from it.

Decided
Jun 21, 2021
Review
265 days
Class
Class II
Product code
MUE
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K896095 (1990). 13 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 10 generations backK896095 Images-on-Call Teleradiology SystemDevices & Services Co. · 1990
  2. 6 generations between
  3. 3 generations backK110033 Feel-DRCSImfou Co., Ltd. · 2011
  4. 2 generations backK152172 Econsole1DRTECH Corporation · 2015
  5. 1 generation backK162670 RSM 1824C with RConsole1DRTECH Corporation · 2017
  6. This deviceK202902 2430MCA with Xmaru WRayence Co., Ltd. · 2021
  7. Descendant · cites it directly · 0 of its ownK243849 2430TCA with Xmaru WRayence Co., Ltd. · 2025
Show all 10 generations
  1. Root · 10 generations backK896095 Images-on-Call Teleradiology SystemDevices & Services Co. · 1990
  2. 9 generations backK962699 Radworks Medical Imaging SoftwareApplicare Medical Imaging, B.V. · 1996
  3. 8 generations backK982862 Radworks Medical Imaging Software with Quality Control ModuleApplicare Medical Imaging, B.V. · 1998
  4. 7 generations backK012211 Efilm WorkstationEfilm Medical, Inc. · 2001 · Recalled
  5. 6 generations backK020995 Efilm Workstation with ModulesEfilm Medical, Inc. · 2002 · Recalled
  6. 5 generations backK070618 Dicompacs, Model 5Oehm Und Rehbein GmbH · 2007
  7. 4 generations backK091364 Dicompacs, Model 5.2, Dicompacs DX-R, Model 1.4Oehm Und Rehbein GmbH · 2009
  8. 3 generations backK110033 Feel-DRCSImfou Co., Ltd. · 2011
  9. 2 generations backK152172 Econsole1DRTECH Corporation · 2015
  10. 1 generation backK162670 RSM 1824C with RConsole1DRTECH Corporation · 2017
  11. This deviceK202902 2430MCA with Xmaru WRayence Co., Ltd. · 2021

Most influential descendants

Showing 1 of 1 · See all
  • K2438492430TCA with Xmaru WRayence Co., Ltd. · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K896095Images-on-Call Teleradiology SystemDevices & Services Co.1990—
−9K962699Radworks Medical Imaging SoftwareApplicare Medical Imaging, B.V.1996—
−8K982862Radworks Medical Imaging Software with Quality Control ModuleApplicare Medical Imaging, B.V.1998—
−7K012211Efilm WorkstationEfilm Medical, Inc.20011
−6K020995Efilm Workstation with ModulesEfilm Medical, Inc.20022
−5K070618Dicompacs, Model 5Oehm Und Rehbein GmbH2007—
−4K091364Dicompacs, Model 5.2, Dicompacs DX-R, Model 1.4Oehm Und Rehbein GmbH2009—
−3K110033Feel-DRCSImfou Co., Ltd.2011—
−2K152172Econsole1DRTECH Corporation2015—
−1K162670RSM 1824C with RConsole1DRTECH Corporation2017—
0 (this device)K2029022430MCA with Xmaru WRayence Co., Ltd.2021—
+1K2438492430TCA with Xmaru WRayence Co., Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
200210
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K202902, 1990–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MUE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MUE device

  1. #1 K253678 MAMMOMAT B.brilliant (11372950)score 13.6 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K162670RSM 1824C with RConsole1
Summary page 4
…LLZ Predicate Device : Detector (RSM 1824C) Software (Rconsole1) 510(k) Number K162670 Applicant DRTECH Corporation Trade/proprietary RSM 1824C with RConsloe1 name…
DRTECH Corporation2017—

Also cleared against K162670: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K2438492430TCA with Xmaru WRayence Co., Ltd.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 7 companies; a new generation was cleared every 2.8 years on median.
  • 3 of the 13 ancestors have a recall of any class.
  • Of its descendants, K243849 (Rayence Co., Ltd., 2025) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K162670.

How does its category compare?

All MUE devices

MUE Full Field Digital, System, X-Ray, Mammographic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · MUE

3in 2025

2007: 62008: 52009: 82010: 102011: 102012: 42013: 72014: 12015: 12016: 12017: 82018: 22019: 22020: 42021: 42022: 32023: 12024: 12025: 32026 (partial year): 4
2007high 10 (2010) · low 1 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MUE

255in 2025

2011: 192 days median2012: 123 days median2013: 207 days median2017: 95 days median2020: 188 days median2021: 164 days median2022: 404 days median2025: 255 days median2026 (partial year): 185 days median
2007high 404 (2022) · low 95 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MUE

4in 2025

2008: 12009: 12010: 22011: 52014: 22017: 62018: 12019: 12023: 12025: 42026 (partial year): 1
2007high 6 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MUE

40in 2025

2008: 42009: 32010: 22011: 102012: 62013: 112014: 72015: 62016: 192017: 1152018: 1452019: 802020: 492021: 252022: 362023: 292024: 332025: 40
2007high 145 (2018) · low 0 (2007)2025

MAUDE reports naming product code MUE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076—00
20085—14
20098—13
201010—22
201110192510
2012412306
20137207011
20141—27
20151—06
20161—019
20178956115
20182—1145
20192—180
20204188049
20214164025
20223404036
20231—129
20241—033
20253255440
202641851—

What is it indicated for?

The 2430MCA Digital Flat Panel X-Ray Detector is indicated for digital imaging solution designed for a mammographic system. It is intended to replace film or screen based mammographic systems in screening mammography. Xmaru W is an integrated software solution indicated for use with the 2430MCA detector.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K202902: 2430MCA with Xmaru W.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K202902

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026