510(k) · Cleared
ClearedDiazyme PLAC® Test for Lp-PLA2 Activity
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Diazyme Laboratories, Inc. · NOE Test, System, Immunoassay, Lipoprotein-Associated Phospholipase A2
Cleared on Aug 6, 2021 after a 290-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Aug 6, 2021
- Review
- 290 days
- Class
- Class II
- Product code
- NOE
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NOE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All NOE devicesNOE Test, System, Immunoassay, Lipoprotein-Associated Phospholipase A2: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · NOE
1in 2021
2026 to Oct 25, outlined.
Median 510(k) review, days · NOE
Too few NOE 510(k)s in any year since 2007 to give a median.
Recalls per year · NOE
2in 2010
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · NOE
1in 2015
MAUDE reports naming product code NOE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 0 | — | 3 | 0 |
| 2009 | 0 | — | 7 | 0 |
| 2010 | 0 | — | 2 | 0 |
| 2011 | 1 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 1 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 1 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Diazyme PLAC® Test for Lp-PLA2 Activity is an enzyme assay for the in vitro quantitative determination of Lp-PLAZ2 (lipoprotein-associated phospholipase A2) activity in EDTA plasma and serum on automated clinical chemistry analyzers. Lp-PLA2 activity is to be used in conjunction with clinical evaluation and patient risk assessment as an aid in predicting risk of coronary heart disease (CHD) in patients with no prior history of cardiovascular events.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K203136 · printed Nov 5, 2026
Cite this page
510(k) Report. “K203136: Diazyme PLAC® Test for Lp-PLA2 Activity.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K203136
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)