510(k) Report

510(k) · Cleared

Cleared

Peak flow meter

K203196510(k) TraditionalCleared May 26, 2021210-day reviewClass II21 CFR 868.1860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shanghai Sonmol Medical Equipment Co., Ltd. · BZH Meter, Peak Flow, Spirometry

Cleared on May 26, 2021 as substantially equivalent to K191239 (Guangzhou Homesun Medical Technology Co., Ltd., 2019) after a 210-day review. Its family tree reaches back 3 generations to 2014.

Decided
May 26, 2021
Review
210 days
Class
Class II
Product code
BZH
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K133975 (2014). No later device cites it as a predicate yet.

  1. Root · 3 generations backK133975 MSA100 Peak Flow MeterBeijing M&B Electronic Instruments Co., Ltd. · 2014
  2. 2 generations backK170281 MSA100BT Peak Flow MeterBeijing M&B Electronic Instruments Co., Ltd. · 2017
  3. 1 generation backK191239 Smart Peak Flow MeterGuangzhou Homesun Medical Technology Co., Ltd. · 2019
  4. This deviceK203196 Peak flow meterShanghai Sonmol Medical Equipment Co., Ltd. · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K133975MSA100 Peak Flow MeterBeijing M&B Electronic Instruments Co., Ltd.2014—
−2K170281MSA100BT Peak Flow MeterBeijing M&B Electronic Instruments Co., Ltd.2017—
−1K191239Smart Peak Flow MeterGuangzhou Homesun Medical Technology Co., Ltd.2019—
0 (this device)K203196Peak flow meterShanghai Sonmol Medical Equipment Co., Ltd.2021—
FIG. 1 — Lineage of K203196, 2014–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BZH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZH device

  1. #1 K252802 Peak Flow Meter (PF-10(BR-PEF231))score 13.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K191239Smart Peak Flow Meter
Summary page 4
…onsor Guangzhou Homesun Medical Technology Co., Ltd Device Name and Model Smart Peak Flow Meter (Model: B1) 510(k) Number K191239 Product Code BZH Regulation Number 21 CFR 868.1860 Regulation Class II Reference d…
Guangzhou Homesun Medical Technology Co., Ltd.2019—
†K053156Mini-Wright Digital, Model 3120001Clement Clarke Intl., Ltd.2006—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 2.2 years on median.
  • None of the 3 ancestors has a recall.

How does its category compare?

All BZH devices

BZH Meter, Peak Flow, Spirometry: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · BZH

3in 2024

2009: 22010: 22013: 12014: 12016: 12017: 12018: 32019: 12020: 22021: 12023: 12024: 32026 (partial year): 2
2007high 3 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZH

371in 2024

2018: 115 days median2024: 371 days median
2007high 371 (2024) · low 115 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZH

No recall names BZH since 2007.

Adverse event reports per year · BZH

1in 2015

2007: 12011: 12013: 32014: 222015: 1
2007high 22 (2014) · low 0 (2008)2025

MAUDE reports naming product code BZH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
20080—00
20092—00
20102—00
20110—01
20120—00
20131—03
20141—022
20150—01
20161—00
20171—00
2018311500
20191—00
20202—00
20211—00
20220—00
20231—00
2024337100
20250—00
20262—0—

What is it indicated for?

This device is intended to monitor a patient’s Peak Expiratory Flow (PEF) and Forced Expiratory Volume in one second (FEV1) at home. The device is designed for adults and children over 5 years of age with caregiver supervision. The device is intended for monitoring respiratory conditions such as asthma. The device is for Over-The-Counter Use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K203196: Peak flow meter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K203196

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026