Barco N.V. · PSY Whole Slide Imaging System
Cleared on Apr 15, 2021 as substantially equivalent to K192259 (Philips Electronics Nederland B.V., 2019) after a 150-day review. Its family tree reaches back 3 generations to 2017. 1 later device descends from it.
- Decided
- Apr 15, 2021
- Review
- 150 days
- Class
- Class II
- Product code
- PSY
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to DEN160056 (2017). 1 later device descends from it, 1 citing it directly.
- Root · 3 generations backDEN160056 Philips IntelliSite Pathology SolutionPhilips Medical Systems Nederland B.V. · 2017
- 2 generations backK172174 Philips IntelliSite Pathology SolutionPhilips Medical Systems Nederland B.V. · 2017
- 1 generation backK192259 Philips IntelliSite Pathology SolutionPhilips Electronics Nederland B.V. · 2019
- This deviceK203364 MDPC-8127Barco N.V. · 2021
- Descendant · cites it directly · 0 of its ownK242545 RadiForce MX317W-PAEizo Corporation · 2025
Most influential descendants
Showing 1 of 1 · See all- K242545RadiForce MX317W-PAEizo Corporation · 2025 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | DEN160056 | Philips IntelliSite Pathology Solution | Philips Medical Systems Nederland B.V. | 2017 | — |
| −2 | K172174 | Philips IntelliSite Pathology Solution | Philips Medical Systems Nederland B.V. | 2017 | — |
| −1 | K192259 | Philips IntelliSite Pathology Solution | Philips Electronics Nederland B.V. | 2019 | — |
| 0 (this device) | K203364 | MDPC-8127 | Barco N.V. | 2021 | — |
| +1 | K242545 | RadiForce MX317W-PA | Eizo Corporation | 2025 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PSY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PSY device
- #1 K232202 Aperio GT 450 DXscore 34.5 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K192259 | Philips IntelliSite Pathology SolutionSummary page 4…ulation number: 21 CFR §864.3700 Predicate device MMPC-4227F1 (PP27QHD), Display used in Philips Intellisite Pathology Solution, referenced in 510(k) - K192259 (Philips Intellisite Pathology Solution) Device description The Barco MDPC-8127 is a medical, color-calibrated display, specifi… | 2019 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K242545 | RadiForce MX317W-PA | 2025 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 4 years and passes through 3 companies; a new generation was cleared every 1.6 years on median.
- None of the 3 ancestors has a recall.
- Of its descendants, K242545 (Eizo Corporation, 2025) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K192259.
How does its category compare?
All PSY devicesPSY Whole Slide Imaging System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · PSY
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PSY
265in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PSY
1so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PSY
1in 2023
MAUDE reports naming product code PSY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 2 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 2 | — | 0 | 1 |
| 2020 | 0 | — | 0 | 1 |
| 2021 | 2 | — | 0 | 0 |
| 2022 | 1 | — | 0 | 0 |
| 2023 | 1 | — | 0 | 1 |
| 2024 | 9 | 265 | 0 | 0 |
| 2025 | 2 | — | 0 | 0 |
| 2026 | 4 | 253 | 1 | — |
What is it indicated for?
The Barco MDPC-8127 device is intended for in vitro diagnostic use to display digital images of histopathology slides acquired from IVD-labeled whole-slide imaging scanners and viewed using IVD-labeled digital pathology image viewing software that have been validated for use with this device. It is an aid to the pathologist to review and interpret digital images of histopathology slides for primary diagnosis. It is the responsibility of the pathologist…
Read the full statement (107 words)
The Barco MDPC-8127 device is intended for in vitro diagnostic use to display digital images of histopathology slides acquired from IVD-labeled whole-slide imaging scanners and viewed using IVD-labeled digital pathology image viewing software that have been validated for use with this device. It is an aid to the pathologist to review and interpret digital images of histopathology slides for primary diagnosis. It is the responsibility of the pathologist to employ appropriate procedures and safeguards to assure the validity of the interpretation of images using the MDPC-8127. The display is not intended for use with digital images from frozen section, cytology, or non-formalin-fixed, paraffin embedded (non-FFPE) hematopathology specimens.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K203364 · printed Nov 4, 2026
Cite this page
510(k) Report. “K203364: MDPC-8127.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K203364
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026