510(k) Report

510(k) · Cleared

Cleared

Gold Tapered Weight Eyelid Implants, Platinum Tapered Weight Eyelid Implants

K203569510(k) TraditionalCleared Jun 11, 2021186-day reviewClass II21 CFR 886.5700

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fci (France Chirurgie Instrumentation) Sas · NCB Weights, Eyelid, Implantable

Cleared on Jun 11, 2021 as substantially equivalent to K150986 (Meddev Corporation, 2015) after a 186-day review. Its family tree reaches back 3 generations to 1999.

Decided
Jun 11, 2021
Review
186 days
Class
Class II
Product code
NCB
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K983607 (1999). No later device cites it as a predicate yet.

  1. Root · 3 generations backK983607 Labtician Lid Load Gold Eyelid Weight ImplantsLabtician Ophthalmics, Inc. · 1999
  2. 2 generations backK011740 Contour Design Gold Eyelid Implant, Model Contour Design (Series 3000)Meddev Corp. · 2001
  3. 1 generation backK150986 Contour Eyelid Weight Implants, ThinProfile Eyelid Weight ImplantsMeddev Corporation · 2015 · Recalled
  4. This deviceK203569 Gold Tapered Weight Eyelid Implants, Platinum Tapered Weight Eyelid…Fci (France Chirurgie Instrumentation) Sas · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K983607Labtician Lid Load Gold Eyelid Weight ImplantsLabtician Ophthalmics, Inc.1999—
−2K011740Contour Design Gold Eyelid Implant, Model Contour Design (Series 3000)Meddev Corp.2001—
−1K150986Contour Eyelid Weight Implants, ThinProfile Eyelid Weight ImplantsMeddev Corporation20152
0 (this device)K203569Gold Tapered Weight Eyelid Implants, Platinum Tapered Weight Eyelid ImplantsFci (France Chirurgie Instrumentation) Sas2021—
FIG. 1 — Lineage of K203569, 1999–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NCB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K150986Contour Eyelid Weight Implants, ThinProfile Eyelid Weight Implants
Summary page 4
…yelid Implants are substantially equivalent to the Contour™ and ThinProfile™ Eyelid Weight Implants marketed by MedDev Corporation, 510(k) Premarket Notification Number: K150986, FDA Classification Product Code MML. The following are included as reference devices for the purpose of sterilization and bioco…
Meddev Corporation20152
†K011740Contour Design Gold Eyelid Implant, Model Contour Design (Series 3000)Meddev Corp.2001—
†K983607Labtician Lid Load Gold Eyelid Weight ImplantsLabtician Ophthalmics, Inc.1999—
†K000127Kurz Pure Gold Upper Eyelids Implant (Oberascher), Model 4001 02-4001 10Heinz Kurz GmbH Medizintechnik2000—
†K170591Altomed Malhotra Platinum SegmentsAltomed Limited2017—
†K011115Kurz Upper Eyelid Implant- Platinum/Iridium,Models Regular 4007 003-007, Special 4007…Heinz Kurz GmbH Medizintechnik2001—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 4 companies; a new generation was cleared every 5.8 years on median.
  • 1 of the 3 ancestors has a recall of any class.

How does its category compare?

All NCB devices

NCB Weights, Eyelid, Implantable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · NCB

1in 2021

2021: 1
2007high 1 (2021) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NCB

Too few NCB 510(k)s in any year since 2007 to give a median.

Recalls per year · NCB

No recall names NCB since 2007.

Adverse event reports per year · NCB

No MAUDE report names NCB since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20211—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

Gold and Platinum Tapered Weight Eyelid Implants are intended for the gravity-assisted treatment of protracted or permanent lagophthalmos, usually resulting from facial paralysis.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K203569: Gold Tapered Weight Eyelid Implants, Platinum Tapered Weight Eyelid Implants.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K203569

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026