Innova Nasal Non-Vented Mask

K203601510(k) TraditionalCleared Apr 30, 2021142-day reviewClass II21 CFR 868.5905

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sleepnet Corporation · BZD Ventilator, Non-Continuous (Respirator)

Cleared on Apr 30, 2021 as substantially equivalent to K102317 (Sleepnet Corporation, 2011) after a 142-day review. Its family tree reaches back 7 generations to 1995. 1 of the 21 devices in its family, counting itself, has a Class I recall.

Decided
Apr 30, 2021
Review
142 days
Class
Class II
Product code
BZD
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K936047 (1995). 20 ancestors in all, the oldest K833786 (1983). No later device cites it as a predicate yet. 1 of the 21 devices in this family, counting this one, has a Class I recall.

  1. Root · 7 generations backK936047 Spectrum (TM) MaskRespironics, Inc. · 1995
  2. 6 generations backK961915 Spectrum Reusable Full Face Mask - Size Petite, Small, Medium, LargeRespironics, Inc. · 1996
  3. 5 generations backK020759 7600 Series Reusable Full-Face Cpap/Nippv Masks Models 7620 Large…Hans Rudolph, Inc. · 2002
  4. 4 generations backK043382 TMS Full Advantage Full Face Mask, Models TMS-2820, TMS-2830, TMS-2840Tiara Medical Systems, Inc. · 2005
  5. 3 generations backK060273 Sleepnet Mojo Full Face Mask -Small, Model NO. 53835, Medium ,Model…Sleepnet Corporation · 2006
  6. 2 generations backK063806 Sleepnet Mojo -NV Full Face Mask, Non-VentedSleepnet Corporation · 2007 · Recalled (Class I)
  7. 1 generation backK102317 IQ Ventilation Nasal MaskSleepnet Corporation · 2011
  8. This deviceK203601 Innova Nasal Non-Vented MaskSleepnet Corporation · 2021

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K936047Spectrum (TM) MaskRespironics, Inc.1995—
−6K961915Spectrum Reusable Full Face Mask - Size Petite, Small, Medium, LargeRespironics, Inc.1996—
−5K0207597600 Series Reusable Full-Face Cpap/Nippv Masks Models 7620 Large, 7630…Hans Rudolph, Inc.2002—
−4K043382TMS Full Advantage Full Face Mask, Models TMS-2820, TMS-2830, TMS-2840Tiara Medical Systems, Inc.2005—
−3K060273Sleepnet Mojo Full Face Mask -Small, Model NO. 53835, Medium ,Model…Sleepnet Corporation2006—
−2K063806Sleepnet Mojo -NV Full Face Mask, Non-VentedSleepnet Corporation2007Class I
−1K102317IQ Ventilation Nasal MaskSleepnet Corporation2011—
0 (this device)K203601Innova Nasal Non-Vented MaskSleepnet Corporation2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198310
198810
199610
199820
199910
200010
200110
200210
200320
200410
200610
FIG. 1 — Lineage of K203601, 1995–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZD device

  1. #1 K250624 myAirscore 15.7 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102317IQ Ventilation Nasal Mask
Summary page 4
…roduct Code: BZD Regulatory Class: II Device: Innovam Nasal Non-Vented mask Predicate Device: K102317 - Sleepnet iQ Ventilation Nasal mask Device Description: The Sleepnet InnovaTm Non-Vented Nasal mask is a patient interface for…
Sleepnet Corporation2011—
†K190533Mojo 2 Full Face Non-Vented Mask, Mojo 2 AAV Non-Vented Full-Face Mask, Veraseal 3 Full…Sleepnet Corporation2019Class I
†K190254Mojo 2 Full Face Vented Mask, Veraseal 3 Full Face Vented Mask, V3 Full Face Vented MaskSleepnet Corporation2019Class I

Also cleared against K102317: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K063806Sleepnet Mojo -NV Full Face Mask, Non-VentedSleepnet Corporation · 2007 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 26 years and passes through 4 companies; a new generation was cleared every 2.4 years on median.
  • 1 of the 20 ancestors has a recall of any class; 1 has a Class I recall.
  • 1 other device also cites its predicate K102317.

How does its category compare?

All BZD devices

BZD Ventilator, Non-Continuous (Respirator): FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · BZD

7in 2025

2007: 212008: 172009: 232010: 122011: 232012: 212013: 232014: 142015: 112016: 122017: 52018: 52019: 62020: 62021: 62022: 42023: 52024: 102025: 72026 (partial year): 10
2007high 23 (2009) · low 4 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZD

189in 2025

2007: 83 days median2008: 108 days median2009: 90 days median2010: 122 days median2011: 125 days median2012: 133 days median2013: 127 days median2014: 172 days median2015: 224 days median2016: 217 days median2017: 221 days median2018: 280 days median2019: 231 days median2020: 137 days median2021: 192 days median2022: 253 days median2023: 204 days median2024: 132 days median2025: 189 days median2026 (partial year): 214 days median
2007high 280 (2018) · low 83 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZD

8in 2023

2007: 292008: 22009: 12011: 12019: 4, 4 Class I2023: 8, 7 Class I2026 (partial year): 2, 2 Class I
2007high 29 (2007) · low 0 (2010)2026

Class I (13 since 2007) Class II/III not classified

Adverse event reports per year · BZD

60,279in 2025

2007: 652008: 672009: 1472010: 1432011: 1892012: 1392013: 822014: 862015: 1142016: 1182017: 1482018: 1012019: 1882020: 1262021: 6,0662022: 90,7682023: 27,9872024: 68,2622025: 60,279
2007high 90,768 (2022) · low 65 (2007)2025

MAUDE reports naming product code BZD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200721832965
200817108267
200923901147
2010121220143
2011231251189
2012211330139
201323127082
201414172086
2015112240114
2016122170118
201752210148
201852800101
201962314 (4)188
202061370126
2021619206,066
20224253090,768
202352048 (7)27,987
202410132068,262
20257189060,279
2026102142 (2)—

What is it indicated for?

The Innova™ Nasal Non-Vented Mask is intended to be used as an accessory to CPAP/bi-level positive pressure systems containing exhalation valves. This product is indicated for use with CPAP/Bi-level systems that have adequate alarms for positive pressure delivery failure. The mask is intended for single patient, multi-use in the home, hospital or institutional environment on adult patients (>30kg/66 lbs.).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K203601: Innova Nasal Non-Vented Mask.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K203601

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026