510(k) Report

510(k) · Cleared

Cleared

ProFound AI Software V3.0

K203822510(k) SpecialCleared Mar 12, 202173-day reviewClass II21 CFR 892.2090

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Icad, Inc. · QDQ Radiological Computer Assisted Detection/Diagnosis Software For Lesions Suspicious For Cancer

Cleared on Mar 12, 2021 as substantially equivalent to K191994 (Icad, Inc., 2019) after a 73-day review. Its family tree reaches back 3 generations to 2018. 1 later device descends from it.

Decided
Mar 12, 2021
Review
73 days
Class
Class II
Product code
QDQ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to DEN180005 (2018). 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backDEN180005 OsteoDetectImagen Technologies, Inc. · 2018
  2. 2 generations backK182373 PowerLook Tomo Detection V2 SoftwareIcad, Inc. · 2018
  3. 1 generation backK191994 ProFound AI Software V2.1Icad, Inc. · 2019
  4. This deviceK203822 ProFound AI Software V3.0Icad, Inc. · 2021
  5. Descendant · cites it directly · 0 of its ownK240417 ProFound Detection (V4.0)Icad, Inc. · 2024

Most influential descendants

Showing 1 of 1 · See all
  • K240417ProFound Detection (V4.0)Icad, Inc. · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3DEN180005OsteoDetectImagen Technologies, Inc.2018—
−2K182373PowerLook Tomo Detection V2 SoftwareIcad, Inc.2018—
−1K191994ProFound AI Software V2.1Icad, Inc.2019—
0 (this device)K203822ProFound AI Software V3.0Icad, Inc.2021—
+1K240417ProFound Detection (V4.0)Icad, Inc.2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K203822, 2018–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QDQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QDQ device

  1. #1 K241831 Transpara (2.1.0)score 15.6 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K191994ProFound AI Software V2.1
Summary page 4
…Detection and Diagnosis Software Product Code: QDQ Regulation Number: 21 CFR 892.2090 Review Panel: Radiology Predicate Device: 510k Number: K191994 Manufacturer: iCAD, Inc. Device Name: ProFound AI® V2.1 Device Description The ProFound AI® V3.0 device detects…
Icad, Inc.2019—
†K182373PowerLook Tomo Detection V2 SoftwareIcad, Inc.2018—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K240417ProFound Detection (V4.0)Icad, Inc.20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 2 companies; a new generation was cleared every 10 months on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K240417 (Icad, Inc., 2024) has gone furthest, with 0 descendants of its own.

How does its category compare?

All QDQ devices

QDQ Radiological Computer Assisted Detection/Diagnosis Software For Lesions Suspicious For Cancer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · QDQ

10so far in 2026, the most since 2007

2018: 22019: 22020: 32021: 52022: 42023: 22024: 72025: 52026 (partial year): 10
2007high 10 (2026) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QDQ

216in 2025

2020: 173 days median2021: 169 days median2022: 131 days median2024: 153 days median2025: 216 days median2026 (partial year): 154 days median
2007high 216 (2025) · low 131 (2022)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QDQ

No recall names QDQ since 2007.

Adverse event reports per year · QDQ

No MAUDE report names QDQ since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20182—00
20192—00
2020317300
2021516900
2022413100
20232—00
2024715300
2025521600
2026101540—

What is it indicated for?

ProFound AI® V3.0 is a computer-assisted detection and diagnosis (CAD) software device intended to be used concurrently by interpreting physicians while reading digital breast tomosynthesis (DBT) exams from compatible DBT systems. The system detects soft tissue densities (masses, architectural distortions and asymmetries) and calcifications in the 3D DBT slices. The detections and Certainty of Finding and Case Scores assist interpreting physicians in identifying soft tissue densities and calcifications that may be confirmed or dismissed by the interpreting Physician

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K203822: ProFound AI Software V3.0.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K203822

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026