510(k) · Cleared
ClearedPowder Free Black Nitrile Examination Gloves, Non-Sterile, Tested for Use with Chemotherapy Drugs and Fentanyl Resistant
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Wrp Asia Pacific Sdn. Bhd. · LZA Polymer Patient Examination Glove
Cleared on Mar 4, 2022 as substantially equivalent to K183287 (Kossan International Sdn Bhd, 2019) after a 393-day review. Its family tree reaches back 1 generation to 2019.
- Decided
- Mar 4, 2022
- Review
- 393 days
- Class
- Class I
- Product code
- LZA
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K183287 (2019). No later device cites it as a predicate yet.
- Root · 1 generation backK183287 Powder Free Nitrile Patient Examination Glove, Blue Colored…Kossan International Sdn Bhd · 2019
- This deviceK210330 Powder Free Black Nitrile Examination Gloves, Non-Sterile, Tested…Wrp Asia Pacific Sdn. Bhd. · 2022
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K183287 | Powder Free Nitrile Patient Examination Glove, Blue Colored, Non-Sterile… | Kossan International Sdn Bhd | 2019 | — |
| 0 (this device) | K210330 | Powder Free Black Nitrile Examination Gloves, Non-Sterile, Tested for Use with… | Wrp Asia Pacific Sdn. Bhd. | 2022 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LZA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LZA device
- #1 K192333 Blue Nitrile Examination Gloves Powder Freescore 71.0 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K183287 | Powder Free Nitrile Patient Examination Glove, Blue Colored, Non-Sterile, Tested for Use…Summary page 4…tient Examination Gloves Device Classification : 1 Regulation Number : 21 CFR 880.6250 Product Code : LZA, QDO 3.0 Predicate Device: K183287 Powder Free Nitrile Patient Examination Glove, Blue Colored, Non-Sterile, Tested for Use with Chemotherapy Drugs and… | 2019 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
- 2 other devices also cite its predicate K183287.
How does its category compare?
All LZA devicesLZA Polymer Patient Examination Glove: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · LZA
24in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LZA
110in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LZA
3so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LZA
73in 2025
MAUDE reports naming product code LZA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 21 | 95 | 0 | 7 |
| 2008 | 18 | 97 | 0 | 2 |
| 2009 | 28 | 112 | 0 | 12 |
| 2010 | 31 | 97 | 0 | 12 |
| 2011 | 26 | 122 | 0 | 9 |
| 2012 | 33 | 110 | 0 | 11 |
| 2013 | 20 | 130 | 0 | 10 |
| 2014 | 27 | 197 | 0 | 8 |
| 2015 | 20 | 112 | 1 | 12 |
| 2016 | 30 | 171 | 1 | 25 |
| 2017 | 44 | 124 | 0 | 4 |
| 2018 | 22 | 178 | 0 | 3 |
| 2019 | 25 | 212 | 0 | 21 |
| 2020 | 30 | 101 | 0 | 4 |
| 2021 | 139 | 111 | 0 | 20 |
| 2022 | 146 | 111 | 0 | 19 |
| 2023 | 62 | 92 | 0 | 24 |
| 2024 | 30 | 89 | 0 | 76 |
| 2025 | 24 | 110 | 0 | 73 |
| 2026 | 15 | 103 | 3 | — |
What is it indicated for?
A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. These gloves were tested for use with chemotherapy drugs and Fentanyl Citrate per ASTM D6978-05 (Re-approved 2013) Standard Practice for assessment of Medical Gloves to Permeation by Chemotherapy Drugs. Chemotherapy Drug Breakthrough Detection Time in Minutes *Carmustine…
Read the full statement (150 words)
A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. These gloves were tested for use with chemotherapy drugs and Fentanyl Citrate per ASTM D6978-05 (Re-approved 2013) Standard Practice for assessment of Medical Gloves to Permeation by Chemotherapy Drugs.
Chemotherapy Drug Breakthrough Detection Time in Minutes
*Carmustine (BCNU) 21.2
Cisplatin > 240
Cyclophosphamide (Cytoxan) > 240
Dacarbazine > 240
Doxorubicin Hydrochloride > 240
Etoposide > 240
Fluorouracil > 240
Ifosfamide > 240
Methotraxate > 240
Mitomycin C > 240
Mitoxantrone > 240
Paclitaxel > 240
*Thiotepa 34.6
Vincristine Sulfate > 240
*WARNING: Please note the following drugs have extremely low permeation times: Carmustine (BCNU): 21.1 minutes and Thiotepa: 34.6. Do not use with Carmustine and Thiotepa.
Fentanyl Resistance Breakthrough Detection Time in Minutes
Fentanyl Citrate Injection No breakthrough up to 240 minutes
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K210330 · printed Nov 6, 2026
Cite this page
510(k) Report. “K210330: Powder Free Black Nitrile Examination Gloves, Non-Sterile, Tested for Use with Chemotherapy Drugs and Fentanyl Resistant.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K210330