510(k) · Cleared
ClearedVolition Plating System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ortho Solutions UK, Ltd. · HRS Plate, Fixation, Bone
Cleared on Apr 13, 2021 as substantially equivalent to K202764 (Ortho Solutions UK, Ltd., 2020) and 1 other predicate after a 40-day review. Its family tree reaches back 12 generations to 1996.
- Decided
- Apr 13, 2021
- Review
- 40 days
- Class
- Class II
- Product code
- HRS
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 12 generations to K962616 (1996). 183 ancestors in all, the oldest K781762 (1978). No later device cites it as a predicate yet.
- Root · 12 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
- 8 generations between
- 3 generations backK100776 Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot SystemSynthes (Usa) · 2010
- 2 generations backK141784 Ortho Solutions Ultos Plating SystemOrtho Solutions Limited · 2014 · Recalled
- 1 generation backK202764 Ortho Solutions Plating SystemOrtho Solutions UK, Ltd. · 2020
- This deviceK210658 Volition Plating SystemOrtho Solutions UK, Ltd. · 2021
Show all 12 generations
- Root · 12 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
- 11 generations backK982732 Synthes (Usa) Distal Radius Plate System (DRPS)Synthes · 1998
- 10 generations backK023007 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2002
- 9 generations backK030198 Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
- 8 generations backK032705 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
- 7 generations backK050932 Distal Volar Radius Anatomical Plate SystemHand Innovations, Inc. · 2005 · Recalled
- 6 generations backK051735 Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper…Smith & Nephew, Inc. · 2005
- 5 generations backK071563 Peri-Loc Periarticular Locked Plating SystemSmith & Nephew, Inc. · 2007
- 4 generations backK090675 Smith & Nephew, Inc. VLP Foot Plating, Screw System and AccessoriesSmith & Nephew, Inc. · 2009
- 3 generations backK100776 Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot SystemSynthes (Usa) · 2010
- 2 generations backK141784 Ortho Solutions Ultos Plating SystemOrtho Solutions Limited · 2014 · Recalled
- 1 generation backK202764 Ortho Solutions Plating SystemOrtho Solutions UK, Ltd. · 2020
- This deviceK210658 Volition Plating SystemOrtho Solutions UK, Ltd. · 2021
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −12 | K962616 | Synthes Dorsal Distal Radius Plate (DDRP) System | Synthes (Usa) | 1996 | — |
| −11 | K982732 | Synthes (Usa) Distal Radius Plate System (DRPS) | Synthes | 1998 | — |
| −10 | K023007 | Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2002 | — |
| −9 | K030198 | Hand Innovations, Inc. Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2003 | — |
| −8 | K032705 | Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2003 | — |
| −7 | K050932 | Distal Volar Radius Anatomical Plate System | Hand Innovations, Inc. | 2005 | 1 |
| −6 | K051735 | Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper Extremity | Smith & Nephew, Inc. | 2005 | — |
| −5 | K071563 | Peri-Loc Periarticular Locked Plating System | Smith & Nephew, Inc. | 2007 | — |
| −4 | K090675 | Smith & Nephew, Inc. VLP Foot Plating, Screw System and Accessories | Smith & Nephew, Inc. | 2009 | — |
| −3 | K100776 | Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot System | Synthes (Usa) | 2010 | — |
| −2 | K141784 | Ortho Solutions Ultos Plating System | Ortho Solutions Limited | 2014 | 2 |
| −1 | K202764 | Ortho Solutions Plating System | Ortho Solutions UK, Ltd. | 2020 | — |
| 0 (this device) | K210658 | Volition Plating System | Ortho Solutions UK, Ltd. | 2021 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1978 | 1 | 0 |
| 1979 | 2 | 0 |
| 1980 | 1 | 0 |
| 1981 | 1 | 0 |
| 1984 | 1 | 0 |
| 1986 | 1 | 0 |
| 1989 | 3 | 0 |
| 1990 | 3 | 0 |
| 1991 | 1 | 0 |
| 1992 | 6 | 0 |
| 1993 | 3 | 0 |
| 1994 | 6 | 0 |
| 1995 | 5 | 0 |
| 1996 | 14 | 0 |
| 1997 | 4 | 0 |
| 1998 | 6 | 0 |
| 1999 | 8 | 0 |
| 2000 | 12 | 0 |
| 2001 | 11 | 0 |
| 2002 | 11 | 0 |
| 2003 | 8 | 0 |
| 2004 | 7 | 0 |
| 2005 | 12 | 0 |
| 2006 | 14 | 0 |
| 2007 | 6 | 0 |
| 2008 | 7 | 0 |
| 2009 | 7 | 0 |
| 2010 | 4 | 0 |
| 2011 | 2 | 0 |
| 2012 | 2 | 0 |
| 2013 | 1 | 0 |
| 2017 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K202764 | Ortho Solutions Plating SystemSummary page 5…System plates are provided with locking and non-locking in 02.7mm, 03.5mm, & 04.0mm previously cleared under K202764. All implants are made from Titanium Alloy (Ti-6AL-4V ELI) per ASTM F136 and are… | 2020 |
| * | K120360 | Ortho Solutions Trauma Plates for OsteosysnthesisSummary page 5…-sterile. Primary Predicate Device: Ortho Solutions Plating System, K202764 Additional Predicate Devices: Ortho Solutions Trauma Plates for Osteosynthesis, K120360 Indications for Use: The Ortho Solutions Plating System is indicated for use in stabilization and… | 2012 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 6 companies; a new generation was cleared every 1.8 years on median.
- 30 of the 183 ancestors have a recall of any class.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
The Volition Plating System is indicated for use in stabilization and fixation of fractures or osteotomies, revision procedures, joint fusion, and reconstruction of small bones of the feet and ankles, including the toes, talus, and calcaneus; the distal fibula and tibia; as well as the fingers, hands, and wrists.
In addition, the non-locking screws and washers are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation, appropriate for the size of the device.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K210658 · printed Nov 6, 2026
Cite this page
510(k) Report. “K210658: Volition Plating System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K210658
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026