510(k) · Cleared
ClearedWill3D
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Hdx Will Corp. · LLZ System, Image Processing, Radiological
Cleared on Dec 15, 2021 as substantially equivalent to K170180 (Hdx Will Corp., 2017) after a 245-day review. Its family tree reaches back 7 generations to 1996.
- Decided
- Dec 15, 2021
- Review
- 245 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 7 generations to K954678 (1996). 14 ancestors in all, the oldest K924810 (1993). No later device cites it as a predicate yet.
- Root · 7 generations backK954678 Pro VisionAlgotec Systems, Ltd. · 1996
- 6 generations backK980648 Pro VisionAlgotec Systems, Ltd. · 1998
- 5 generations backK992654 Plug 'N View 3D, Version 1.0Voxar Limited · 1999
- 4 generations backK013878 Cybermed, Inc., V-WorksCybermed, Inc. · 2001
- 3 generations backK053155 VimplantCybermed, Inc. · 2005
- 2 generations backK070803 InvivodentalAnatomage, Inc. · 2007
- 1 generation backK170180 Will3DHdx Will Corp. · 2017
- This deviceK211114 Will3DHdx Will Corp. · 2021
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K954678 | Pro Vision | Algotec Systems, Ltd. | 1996 | — |
| −6 | K980648 | Pro Vision | Algotec Systems, Ltd. | 1998 | — |
| −5 | K992654 | Plug 'N View 3D, Version 1.0 | Voxar Limited | 1999 | — |
| −4 | K013878 | Cybermed, Inc., V-Works | Cybermed, Inc. | 2001 | — |
| −3 | K053155 | Vimplant | Cybermed, Inc. | 2005 | — |
| −2 | K070803 | Invivodental | Anatomage, Inc. | 2007 | — |
| −1 | K170180 | Will3D | Hdx Will Corp. | 2017 | — |
| 0 (this device) | K211114 | Will3D | Hdx Will Corp. | 2021 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 2 | 0 |
| 1997 | 1 | 0 |
| 2004 | 2 | 0 |
| 2006 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K170180 | Will3DSummary page 5…312 4. Identification of Predicate Device(s) [21 CFR 807.92(a)(3)] The identified predicate devices within this submission are shown as follow; Predicate device K170180 HDX WILL CORP. Will3D There are no significant differences between the Will3D and the predicate d… | 2017 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 5 companies; a new generation was cleared every 2.5 years on median.
- None of the 14 ancestors has a recall.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
Will3D is a software application used for the display and 3D visualization of medical image files from scanning devices, such as Dental CT scanner. It is intended for use by radiologists, clinicians, referring physicians and other qualified individuals to retrieve, process, render, review, store, print, assist in diagnosis, and distribute images utilizing standard PC hardware. Additionally, Will3D is a preoperative software application used for the simulation and evaluation of dental implants, orthodontic planning and surgical treatments.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K211114 · printed Nov 6, 2026
Cite this page
510(k) Report. “K211114: Will3D.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K211114
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026