510(k) Report

510(k) · Cleared

Cleared

Safety Winged Blood Collection Sets

K211293510(k) TraditionalCleared Jun 25, 202160-day reviewClass II21 CFR 880.5570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Promisemed Hangzhou Meditech Co., Ltd. · FMI Needle, Hypodermic, Single Lumen

Cleared on Jun 25, 2021 as substantially equivalent to K170276 (Gemtier Medical (Shanghai), Inc., 2017) after a 60-day review. Its family tree reaches back 5 generations to 1991. 1 later device descends from it.

Decided
Jun 25, 2021
Review
60 days
Class
Class II
Product code
FMI
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K912563 (1991). 6 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 5 generations backK912563 Angel Wing Safety Blood Collection and Infusion SEMbo Laboratories, Inc. · 1991
  2. 4 generations backK011786 Vacuette Safety Blood Collection SetGreiner Vacuette North America, Inc. · 2001 · Recalled
  3. 3 generations backK080235 Safety Infusion SetGreiner Bio-One Vacuette North America · 2008
  4. 2 generations backK121908 Safety Infusion SetGreiner Bio-One North America, Inc. · 2012
  5. 1 generation backK170276 Safety Blood Collection Device for Single UseGemtier Medical (Shanghai), Inc. · 2017
  6. This deviceK211293 Safety Winged Blood Collection SetsPromisemed Hangzhou Meditech Co., Ltd. · 2021
  7. Descendant · cites it directly · 0 of its ownK243806 Safety Winged Blood Collection SetsPromisemed Hangzhou Meditech Co., Ltd. · 2025

Most influential descendants

Showing 1 of 1 · See all
  • K243806Safety Winged Blood Collection SetsPromisemed Hangzhou Meditech Co., Ltd. · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K912563Angel Wing Safety Blood Collection and Infusion SEMbo Laboratories, Inc.1991—
−4K011786Vacuette Safety Blood Collection SetGreiner Vacuette North America, Inc.20012
−3K080235Safety Infusion SetGreiner Bio-One Vacuette North America2008—
−2K121908Safety Infusion SetGreiner Bio-One North America, Inc.2012—
−1K170276Safety Blood Collection Device for Single UseGemtier Medical (Shanghai), Inc.2017—
0 (this device)K211293Safety Winged Blood Collection SetsPromisemed Hangzhou Meditech Co., Ltd.2021—
+1K243806Safety Winged Blood Collection SetsPromisemed Hangzhou Meditech Co., Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K211293, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FMI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FMI device

  1. #1 K252886 Pen Needlescore 14.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170276Safety Blood Collection Device for Single Use
Summary page 4
…21 CFR 807.92(a)(3) Predicate [510(k)] # Predicate Trade Name Product Code K170276 Gemtier Medical (Shanghai) Inc. Safety Blood Collection Device FMI/FPA…
Gemtier Medical (Shanghai), Inc.2017—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K243806Safety Winged Blood Collection SetsPromisemed Hangzhou Meditech Co., Ltd.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 6 companies; a new generation was cleared every 5.4 years on median.
  • 2 of the 6 ancestors have a recall of any class.
  • Of its descendants, K243806 (Promisemed Hangzhou Meditech Co., Ltd., 2025) has gone furthest, with 0 descendants of its own.

How does its category compare?

All FMI devices

FMI Needle, Hypodermic, Single Lumen: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · FMI

11in 2025

2007: 152008: 102009: 72010: 152011: 122012: 172013: 112014: 142015: 102016: 202017: 92018: 202019: 122020: 112021: 182022: 232023: 182024: 32025: 112026 (partial year): 12
2007high 23 (2022) · low 3 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FMI

141in 2025

2007: 71 days median2008: 85 days median2009: 177 days median2010: 119 days median2011: 113 days median2012: 107 days median2013: 87 days median2014: 155 days median2015: 89 days median2016: 217 days median2017: 253 days median2018: 176 days median2019: 186 days median2020: 263 days median2021: 143 days median2022: 189 days median2023: 112 days median2024: 90 days median2025: 141 days median2026 (partial year): 119 days median
2007high 263 (2020) · low 71 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FMI

1in 2024

2007: 22008: 42009: 32010: 792011: 52012: 12013: 12014: 32015: 12017: 162019: 52020: 32021: 72023: 22024: 12026 (partial year): 1, 1 Class I
2007high 79 (2010) · low 0 (2016)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · FMI

2,424in 2025

2007: 2082008: 1772009: 2632010: 2492011: 2402012: 2152013: 2552014: 2872015: 5672016: 9412017: 1,5472018: 2,3982019: 4,8962020: 4,2452021: 4,5322022: 4,8852023: 4,9862024: 4,0532025: 2,424
2007high 4,986 (2023) · low 177 (2008)2025

MAUDE reports naming product code FMI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715712208
200810854177
200971773263
20101511979249
2011121135240
2012171071215
201311871255
2014141553287
201510891567
2016202170941
20179253161,547
20182017602,398
20191218654,896
20201126334,245
20211814374,532
20222318904,885
20231811224,986
202439014,053
20251114102,424
2026121191 (1)—

What is it indicated for?

The safety winged blood collection set is single-use, sterile, winged venipuncture needle bonded to a flexible tubing with or without a luer adaper and/or tube holder. The device is used for blood collection and/or the short-term infusion of intravenous fluids (up to 2 hours under direct clinical supervision). The blood-collection needle is designed to be covered with a safety mechanism, which can be activated to cover the needle immediately following venipuncture to aid in the protection against accidental needlestick injury.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K211293: Safety Winged Blood Collection Sets.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K211293

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026