510(k) Report

510(k) · Cleared

Cleared

Evo sEEG System

K211367510(k) TraditionalCleared Sep 1, 2021120-day reviewClass II21 CFR 882.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Neuroone Medical Technologies Corp. · GZL Electrode, Depth

Cleared on Sep 1, 2021 as substantially equivalent to K170959 (Dixi Medical, 2017) after a 120-day review. Its family tree reaches back 7 generations to 1981. 2 later devices descend from it.

Decided
Sep 1, 2021
Review
120 days
Class
Class II
Product code
GZL
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K811452 (1981). 18 ancestors in all. 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2016: 1 other ancestor2001: 1 other ancestor2005: 1 other ancestor1999: 3 other ancestors1997: 1 other ancestor1989: 1 other ancestor1986: 1 other ancestor1998: 1 other ancestor1995: 1 other ancestor2022: 1 descendant cleared2025: 1 descendant clearedK811452 · Brown-Roberts-Wells Stereotaxic Sytem · Trent Wells, Inc. · 1981K961858 · Cosgrove Depth Electrode Kit (Cdek) · Radionics, Inc. · 1996K991522 · Microtargeting Electrode · FHC, Inc. · 2000 · recalled×2: 2 generations cleared close together, K033173 (2004), K041604 (2004) K053358 · Depth Electrode, Foramen Ovale Depth Electrodes, Wyler Sphenoidal Depth Electrodes · Ad-Tech Medical Instrument Corp · 2006K170959 · DIXI Medical Microdeep Depth Electrode · Dixi Medical · 2017 · recalled19801990200020102020
  1. Root · 7 generations backK811452 Brown-Roberts-Wells Stereotaxic SytemTrent Wells, Inc. · 1981
  2. 6 generations backK961858 Cosgrove Depth Electrode Kit (Cdek)Radionics, Inc. · 1996
  3. 5 generations backK991522 Microtargeting ElectrodeFHC, Inc. · 2000 · Recalled
  4. 4 generations backK033173 Micro Targeting ElectrodeFHC, Inc. · 2004
  5. 3 generations backK041604 Macro-Micro Depth ElectrodeAd-Tech Medical Instrument Corp · 2004
  6. 2 generations backK053358 Depth Electrode, Foramen Ovale Depth Electrodes, Wyler Sphenoidal…Ad-Tech Medical Instrument Corp · 2006
  7. 1 generation backK170959 DIXI Medical Microdeep Depth ElectrodeDixi Medical · 2017 · Recalled
  8. This deviceK211367 Evo sEEG SystemNeuroone Medical Technologies Corp. · 2021
  9. Descendant · cites it directly · 1 of its ownK222404 Evo® sEEG SystemNeuroone Medical Technologies Corp. · 2022
  10. Descendant · 2 generations on · 0 of its ownK250363 Depth Electrode (RSDE-08); Depth Electrode (RSDE-10); Depth…Beijing Sinovation Medical Technology Co., Ltd. · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K222404Evo® sEEG SystemNeuroone Medical Technologies Corp. · 2022 · cites it directly1descendant
  • K250363Depth Electrode (RSDE-08); Depth Electrode (RSDE-10); Depth Electrode (RSDE-12); Depth…Beijing Sinovation Medical Technology Co., Ltd. · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K811452Brown-Roberts-Wells Stereotaxic SytemTrent Wells, Inc.1981—
−6K961858Cosgrove Depth Electrode Kit (Cdek)Radionics, Inc.1996—
−5K991522Microtargeting ElectrodeFHC, Inc.20003
−4K033173Micro Targeting ElectrodeFHC, Inc.2004—
−3K041604Macro-Micro Depth ElectrodeAd-Tech Medical Instrument Corp2004—
−2K053358Depth Electrode, Foramen Ovale Depth Electrodes, Wyler Sphenoidal Depth…Ad-Tech Medical Instrument Corp2006—
−1K170959DIXI Medical Microdeep Depth ElectrodeDixi Medical20179
0 (this device)K211367Evo sEEG SystemNeuroone Medical Technologies Corp.2021—
+1K222404Evo® sEEG SystemNeuroone Medical Technologies Corp.2022—
+2K250363Depth Electrode (RSDE-08); Depth Electrode (RSDE-10); Depth Electrode…Beijing Sinovation Medical Technology Co., Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
198910
199510
199710
199810
199930
200110
200510
201610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202510
FIG. 1 — Lineage of K211367, 1981–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GZL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GZL device

  1. #1 K253970 Wovyn Depth Electrodescore 13.3 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170959DIXI Medical Microdeep Depth Electrode
Summary page 5
…Subject Device Predicate Device K211367 K170959 DIXI Medical Microdeep Depth Trade/Device Name:…
Dixi Medical20179

Also cleared against K170959: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K222404Evo® sEEG SystemNeuroone Medical Technologies Corp.20221

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 40 years and passes through 6 companies; a new generation was cleared every 3.8 years on median.
  • 4 of the 18 ancestors have a recall of any class.
  • Of its descendants, K222404 (Neuroone Medical Technologies Corp., 2022) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K170959.

How does its category compare?

All GZL devices

GZL Electrode, Depth: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · GZL

2in 2025

2007: 32009: 12011: 12012: 12013: 12014: 12016: 22017: 42018: 32020: 12021: 32022: 32023: 32025: 22026 (partial year): 1
2007high 4 (2017) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GZL

206in 2023

2007: 166 days median2017: 222 days median2018: 58 days median2021: 262 days median2022: 90 days median2023: 206 days median
2007high 262 (2021) · low 58 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GZL

3in 2024

2008: 32009: 22014: 12021: 92024: 3
2007high 9 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GZL

12in 2025

2008: 82009: 52010: 62011: 42012: 82013: 252014: 72015: 142016: 92017: 32018: 22019: 132020: 242021: 132022: 102023: 302024: 162025: 12
2007high 30 (2023) · low 0 (2007)2025

MAUDE reports naming product code GZL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007316600
20080—38
20091—25
20100—06
20111—04
20121—08
20131—025
20141—17
20150—014
20162—09
2017422203
201835802
20190—013
20201—024
20213262913
2022390010
20233206030
20240—316
20252—012
20261—0—

What is it indicated for?

The Evo sEEG System is intended for temporary (less than 24 hours) use with recording, monitoring, and stimulation equipment for the recording, monitoring, and stimulation of electrical signals at the subsurface level of the brain.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K211367: Evo sEEG System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K211367

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026