510(k) · Cleared
ClearedLogiq E10
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
GE Healthcare · IYN System, Imaging, Pulsed Doppler, Ultrasonic
Cleared on Sep 10, 2021 as substantially equivalent to K200158 (GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, 2020) after a 120-day review. Its family tree reaches back 21 generations to 1995. 11 later devices descend from it.
- Decided
- Sep 10, 2021
- Review
- 120 days
- Class
- Class II
- Product code
- IYN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 21 generations to K935595 (1995). 153 ancestors in all, the oldest K863700 (1987). 11 later devices descend from it, 3 citing it directly.
- Root · 21 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
- 17 generations between
- 3 generations backK163077 LOGIQ E9, LOGIQ E9 XDClear 2.0GE Medical Systems Ultrasound and Primary Care Diagnostics · 2016
- 2 generations backK173555 Logiq E10GE Healthcare · 2017 · Recalled
- 1 generation backK200158 Logiq E10GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · 2020
- This deviceK211488 Logiq E10GE Healthcare · 2021
- Descendant · cites it directly · 5 of its ownK231966 Logiq E10GE Medical Systems Ultrasound and Primary Care Diagnostics · 2023
- Descendant · cites it directly · 2 of its ownK220940 EchoPAC Software Only, EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics · 2022
- Descendant · 2 generations on · 1 of its ownK251342 EchoPAC Software Only / EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics · 2025
- Descendant · cites it directly · 1 of its ownK242168 Voluson Expert 18; Voluson Expert 20; Voluson Expert 22GE Medical Systems Ultrasound and Primary Care Diagnostics · 2024
- Descendant · 3 generations on · 0 of its ownK261623 EchoPAC Software Only / EchoPAC Plug-in (v211)GE Medical Systems Ultrasound and Primary Care Diagnostics · 2026
Show all 21 generations
- Root · 21 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
- 20 generations backK973767 Harmonic Imaging with ContrastAcuson Corp. · 1997
- 19 generations backK022567 Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp. · 2002
- 18 generations backK032114 Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2003
- 17 generations backK041319 Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004
- 16 generations backK042770 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
- 15 generations backK050240 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
- 14 generations backK052894 Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
- 13 generations backK063138 Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006
- 12 generations backK063803 Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · Recalled
- 11 generations backK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007
- 10 generations backK083095 Sonixtouch Ultrasound SystemUltrasonix Medical Corporation · 2008
- 9 generations backK092271 GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3…GE Healthcare · 2009 · Recalled
- 8 generations backK110943 Logiq E9GE Healthcare · 2011 · Recalled
- 7 generations backK113690 GE Logiq I, Logiq E and Vivid EGE Healthcare · 2011 · Recalled
- 6 generations backK123564 Logiq E9 Diagnostic Ultrasound SystemGE Healthcare · 2012 · Recalled
- 5 generations backK131514 GE Vivid E9 Diagnostic Ultrasound Imaging SystemGe Vingmed Ultrasound AS · 2013 · Recalled
- 4 generations backK152309 LOGIQ E9, LOGIQ E9 XDClear 2.0GE Medical Systems Ultrasound and Primary Care Diagnostics · 2015 · Recalled
- 3 generations backK163077 LOGIQ E9, LOGIQ E9 XDClear 2.0GE Medical Systems Ultrasound and Primary Care Diagnostics · 2016
- 2 generations backK173555 Logiq E10GE Healthcare · 2017 · Recalled
- 1 generation backK200158 Logiq E10GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · 2020
- This deviceK211488 Logiq E10GE Healthcare · 2021
Showing 5 of 11 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 11 · See all- K231966Logiq E10GE Medical Systems Ultrasound and Primary Care Diagnostics · 2023 · cites it directly5descendants
- K220940EchoPAC Software Only, EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics · 2022 · cites it directly2descendants
- K251342EchoPAC Software Only / EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics · 2025 · 2 generations on1descendant
- K242168Voluson Expert 18; Voluson Expert 20; Voluson Expert 22GE Medical Systems Ultrasound and Primary Care Diagnostics · 2024 · cites it directly1descendant
- K261623EchoPAC Software Only / EchoPAC Plug-in (v211)GE Medical Systems Ultrasound and Primary Care Diagnostics · 2026 · 3 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −21 | K935595 | Acuson Model 3001 | Acuson Corp. | 1995 | — |
| −20 | K973767 | Harmonic Imaging with Contrast | Acuson Corp. | 1997 | — |
| −19 | K022567 | Sequoia Signature II Diagnostic Ultrasound System | Acuson Corp. | 2002 | — |
| −18 | K032114 | Sequoia 8.0 Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc. | 2003 | — |
| −17 | K041319 | Sequoia Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc. | 2004 | — |
| −16 | K042770 | Modification to Acuson CV70 Cardiovascular System | Siemens Medical Solutions USA, Inc. | 2004 | 1 |
| −15 | K050240 | Modification to Acuson CV70 Cardiovascular System | Siemens Medical Solutions USA, Inc. | 2005 | 1 |
| −14 | K052894 | Sonoline G60 S Ultrasound System | Siemens Medical Solutions USA, Inc. | 2005 | 1 |
| −13 | K063138 | Modification to Acuson Antares Ultrasound System | Siemens Medical Solutions USA, Inc. | 2006 | — |
| −12 | K063803 | Acuson Antares Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc., Ultrasound DI | 2007 | 9 |
| −11 | K072786 | Acuson S2000 Ultrasound System | Siemens Medical Solutions USA, Inc. | 2007 | — |
| −10 | K083095 | Sonixtouch Ultrasound System | Ultrasonix Medical Corporation | 2008 | — |
| −9 | K092271 | GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4 | GE Healthcare | 2009 | 1 |
| −8 | K110943 | Logiq E9 | GE Healthcare | 2011 | 2 |
| −7 | K113690 | GE Logiq I, Logiq E and Vivid E | GE Healthcare | 2011 | 1 |
| −6 | K123564 | Logiq E9 Diagnostic Ultrasound System | GE Healthcare | 2012 | 1 |
| −5 | K131514 | GE Vivid E9 Diagnostic Ultrasound Imaging System | Ge Vingmed Ultrasound AS | 2013 | 2 |
| −4 | K152309 | LOGIQ E9, LOGIQ E9 XDClear 2.0 | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2015 | 1 |
| −3 | K163077 | LOGIQ E9, LOGIQ E9 XDClear 2.0 | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2016 | — |
| −2 | K173555 | Logiq E10 | GE Healthcare | 2017 | 2 |
| −1 | K200158 | Logiq E10 | GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC | 2020 | — |
| 0 (this device) | K211488 | Logiq E10 | GE Healthcare | 2021 | — |
| +1 | K231966 | Logiq E10 | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2023 | — |
| +1 | K220940 | EchoPAC Software Only, EchoPAC Plug-in | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2022 | — |
| +2 | K251342 | EchoPAC Software Only / EchoPAC Plug-in | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2025 | — |
| +1 | K242168 | Voluson Expert 18; Voluson Expert 20; Voluson Expert 22 | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2024 | — |
| +3 | K261623 | EchoPAC Software Only / EchoPAC Plug-in (v211) | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2026 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1987 | 1 | 0 |
| 1989 | 1 | 0 |
| 1992 | 1 | 0 |
| 1994 | 4 | 0 |
| 1995 | 5 | 0 |
| 1996 | 1 | 0 |
| 1997 | 6 | 0 |
| 1998 | 2 | 0 |
| 1999 | 7 | 0 |
| 2000 | 7 | 0 |
| 2001 | 7 | 0 |
| 2002 | 11 | 0 |
| 2003 | 12 | 0 |
| 2004 | 14 | 0 |
| 2005 | 10 | 0 |
| 2006 | 8 | 0 |
| 2007 | 5 | 0 |
| 2008 | 5 | 0 |
| 2009 | 5 | 0 |
| 2010 | 7 | 0 |
| 2011 | 3 | 0 |
| 2012 | 7 | 0 |
| 2013 | 2 | 0 |
| 2014 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2022 | 1 | 0 |
| 2023 | 1 | 0 |
| 2024 | 3 | 0 |
| 2025 | 3 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IYN device
- #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K200158 | Logiq E10Summary page 4…stem, 21CFR 892.1560, 90- IYO Diagnostic Ultrasound Transducer, 21 CFR 892.1570, 90-ITX Primary Predicate Device: K200158 LOGIQ E10 Diagnostic Ultrasound System Reference Device(s): Vivid E95 K202658 Diagnostic Ultrasound System Device… | 2020 |
| † | K202658 | Vivid E80/ Vivid E90/ Vivid E95 | 2021 |
What descends from it? (11)
See all 113 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 26 years and passes through 8 companies; a new generation was cleared every 12 months on median.
- 50 of the 153 ancestors have a recall of any class.
- Of its descendants, K231966 (GE Medical Systems Ultrasound and Primary Care Diagnostics, 2023) has gone furthest, with 5 descendants of its own.
How does its category compare?
All IYN devicesIYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · IYN
57in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · IYN
124in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IYN
10in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · IYN
610in 2025
MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 26 | 16 | 3 |
| 2008 | 25 | 18 | 12 | 2 |
| 2009 | 18 | 29 | 8 | 9 |
| 2010 | 29 | 67 | 10 | 17 |
| 2011 | 39 | 46 | 8 | 18 |
| 2012 | 43 | 37 | 3 | 20 |
| 2013 | 51 | 60 | 8 | 18 |
| 2014 | 56 | 39 | 2 | 48 |
| 2015 | 54 | 55 | 3 | 116 |
| 2016 | 60 | 56 | 2 | 145 |
| 2017 | 64 | 83 | 0 | 146 |
| 2018 | 59 | 85 | 7 | 85 |
| 2019 | 47 | 79 | 0 | 59 |
| 2020 | 57 | 72 | 4 | 67 |
| 2021 | 46 | 105 | 8 | 213 |
| 2022 | 53 | 105 | 10 | 186 |
| 2023 | 44 | 115 | 4 | 229 |
| 2024 | 50 | 119 | 1 | 266 |
| 2025 | 57 | 124 | 10 | 610 |
| 2026 | 44 | 107 | 2 (1) | — |
What is it indicated for?
LOGIQ E10 is intended for use by a qualified physician for ultrasound evaluation of Fetal / Obstetrics; Abdominal (including Renal, Gynecology/Pelvic); Pediatric; Small Organ (Breast, Testes, Thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (Adult and Pediatric); Peripheral Vascular; Musculo-skeletal Conventional and Superficial; Urology (including Prostate); Transrectal; Transvaginal; Transesophageal and Intraoperative (Abdominal and Vascular).…
Read the full statement (104 words)
LOGIQ E10 is intended for use by a qualified physician for ultrasound evaluation of Fetal / Obstetrics; Abdominal (including Renal, Gynecology/Pelvic); Pediatric; Small Organ (Breast, Testes, Thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (Adult and Pediatric); Peripheral Vascular; Musculo-skeletal Conventional and Superficial; Urology (including Prostate); Transrectal; Transvaginal; Transesophageal and Intraoperative (Abdominal and Vascular).
Modes of operation include: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded Pulse, 3D/4D Imaging mode, Elastography, Shear Wave Elastography, Attenuation Imaging and Combined modes: B/M, B/Color, B/PWD, B/Color/PWD, B/Power/PWD. The LOGIQ E10 is intended to be used in a hospital or medical clinic.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K211488 · printed Nov 3, 2026
Cite this page
510(k) Report. “K211488: Logiq E10.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K211488
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026