510(k) Report

510(k) · Cleared

Cleared

Logiq E10

K211488510(k) TraditionalCleared Sep 10, 2021120-day reviewClass II21 CFR 892.1550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

GE Healthcare · IYN System, Imaging, Pulsed Doppler, Ultrasonic

Cleared on Sep 10, 2021 as substantially equivalent to K200158 (GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, 2020) after a 120-day review. Its family tree reaches back 21 generations to 1995. 11 later devices descend from it.

Decided
Sep 10, 2021
Review
120 days
Class
Class II
Product code
IYN
Recalls
None
Predicates
1

Its longest line of descent runs back 21 generations to K935595 (1995). 153 ancestors in all, the oldest K863700 (1987). 11 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2014: 1 other ancestor2013: 2 other ancestors2012: 7 other ancestors2011: 3 other ancestors2010: 7 other ancestors2003: 12 other ancestors2008: 5 other ancestors2005: 10 other ancestors2001: 7 other ancestors2009: 5 other ancestors2007: 5 other ancestors2006: 8 other ancestors2004: 14 other ancestors2002: 11 other ancestors2000: 7 other ancestors1999: 7 other ancestors1998: 2 other ancestors1997: 6 other ancestors1995: 5 other ancestors1996: 1 other ancestor1987: 1 other ancestor1994: 4 other ancestors1992: 1 other ancestor1989: 1 other ancestor2024: 3 descendants cleared2022: 1 descendant cleared2023: 1 descendant cleared2025: 3 descendants cleared2026: 3 descendants clearedReference device: K202658 · Vivid E80/ Vivid E90/ Vivid E95 · GE Medical Systems Ultrasound and Primary Care Diagnostics · 2021K935595 · Acuson Model 3001 · Acuson Corp. · 1995K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K032114 · Sequoia 8.0 Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2003×3: 3 generations cleared close together, K041319 (2004), K042770 (2004), K050240 (2005) K052894 · Sonoline G60 S Ultrasound System · Siemens Medical Solutions USA, Inc. · 2005 · recalled×2: 2 generations cleared close together, K063138 (2006), K063803 (2007) K072786 · Acuson S2000 Ultrasound System · Siemens Medical Solutions USA, Inc. · 2007K083095 · Sonixtouch Ultrasound System · Ultrasonix Medical Corporation · 2008K092271 · GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4 · GE Healthcare · 2009 · recalledK110943 · Logiq E9 · GE Healthcare · 2011 · recalledK113690 · GE Logiq I, Logiq E and Vivid E · GE Healthcare · 2011 · recalledK123564 · Logiq E9 Diagnostic Ultrasound System · GE Healthcare · 2012 · recalledK131514 · GE Vivid E9 Diagnostic Ultrasound Imaging System · Ge Vingmed Ultrasound AS · 2013 · recalledK152309 · LOGIQ E9, LOGIQ E9 XDClear 2.0 · GE Medical Systems Ultrasound and Primary Care Diagnostics · 2015 · recalledK163077 · LOGIQ E9, LOGIQ E9 XDClear 2.0 · GE Medical Systems Ultrasound and Primary Care Diagnostics · 2016K173555 · Logiq E10 · GE Healthcare · 2017 · recalledK200158 · Logiq E10 · GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · 20201990200020102020
Other ancestors, by generationDescendants, by generation 5 generations back: 2 other ancestors6 generations back: 7 other ancestors7 generations back: 10 other ancestors8 generations back: 16 other ancestors9 generations back: 19 other ancestors10 generations back: 27 other ancestors11 generations back: 16 other ancestors12 generations back: 10 other ancestors13 generations back: 6 other ancestors14 generations back: 10 other ancestors15 generations back: 9 other ancestors 1 generation forward: 3 descendants2 generations forward: 7 descendants3 generations forward: 1 descendant K200158 · Logiq E10 · GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · 2020K173555 · Logiq E10 · GE Healthcare · 2017 · recalledK163077 · LOGIQ E9, LOGIQ E9 XDClear 2.0 · GE Medical Systems Ultrasound and Primary Care Diagnostics · 2016K152309 · LOGIQ E9, LOGIQ E9 XDClear 2.0 · GE Medical Systems Ultrasound and Primary Care Diagnostics · 2015 · recalledK131514 · GE Vivid E9 Diagnostic Ultrasound Imaging System · Ge Vingmed Ultrasound AS · 2013 · recalledK123564 · Logiq E9 Diagnostic Ultrasound System · GE Healthcare · 2012 · recalledK113690 · GE Logiq I, Logiq E and Vivid E · GE Healthcare · 2011 · recalledK110943 · Logiq E9 · GE Healthcare · 2011 · recalledK092271 · GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4 · GE Healthcare · 2009 · recalledK083095 · Sonixtouch Ultrasound System · Ultrasonix Medical Corporation · 2008K072786 · Acuson S2000 Ultrasound System · Siemens Medical Solutions USA, Inc. · 2007K063803 · Acuson Antares Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · recalledK063138 · Modification to Acuson Antares Ultrasound System · Siemens Medical Solutions USA, Inc. · 2006K052894 · Sonoline G60 S Ultrasound System · Siemens Medical Solutions USA, Inc. · 2005 · recalledK050240 · Modification to Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2005 · recalledK042770 · Modification to Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2004 · recalledK041319 · Sequoia Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2004K032114 · Sequoia 8.0 Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2003K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K935595 · Acuson Model 3001 · Acuson Corp. · 1995−20−15−10−50
  1. Root · 21 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 17 generations between
  3. 3 generations backK163077 LOGIQ E9, LOGIQ E9 XDClear 2.0GE Medical Systems Ultrasound and Primary Care Diagnostics · 2016
  4. 2 generations backK173555 Logiq E10GE Healthcare · 2017 · Recalled
  5. 1 generation backK200158 Logiq E10GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · 2020
  6. This deviceK211488 Logiq E10GE Healthcare · 2021
  7. Descendant · cites it directly · 5 of its ownK231966 Logiq E10GE Medical Systems Ultrasound and Primary Care Diagnostics · 2023
  8. Descendant · cites it directly · 2 of its ownK220940 EchoPAC Software Only, EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics · 2022
  9. Descendant · 2 generations on · 1 of its ownK251342 EchoPAC Software Only / EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics · 2025
  10. Descendant · cites it directly · 1 of its ownK242168 Voluson Expert 18; Voluson Expert 20; Voluson Expert 22GE Medical Systems Ultrasound and Primary Care Diagnostics · 2024
  11. Descendant · 3 generations on · 0 of its ownK261623 EchoPAC Software Only / EchoPAC Plug-in (v211)GE Medical Systems Ultrasound and Primary Care Diagnostics · 2026
Show all 21 generations
  1. Root · 21 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 20 generations backK973767 Harmonic Imaging with ContrastAcuson Corp. · 1997
  3. 19 generations backK022567 Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp. · 2002
  4. 18 generations backK032114 Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2003
  5. 17 generations backK041319 Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004
  6. 16 generations backK042770 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
  7. 15 generations backK050240 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  8. 14 generations backK052894 Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  9. 13 generations backK063138 Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006
  10. 12 generations backK063803 Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · Recalled
  11. 11 generations backK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007
  12. 10 generations backK083095 Sonixtouch Ultrasound SystemUltrasonix Medical Corporation · 2008
  13. 9 generations backK092271 GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3…GE Healthcare · 2009 · Recalled
  14. 8 generations backK110943 Logiq E9GE Healthcare · 2011 · Recalled
  15. 7 generations backK113690 GE Logiq I, Logiq E and Vivid EGE Healthcare · 2011 · Recalled
  16. 6 generations backK123564 Logiq E9 Diagnostic Ultrasound SystemGE Healthcare · 2012 · Recalled
  17. 5 generations backK131514 GE Vivid E9 Diagnostic Ultrasound Imaging SystemGe Vingmed Ultrasound AS · 2013 · Recalled
  18. 4 generations backK152309 LOGIQ E9, LOGIQ E9 XDClear 2.0GE Medical Systems Ultrasound and Primary Care Diagnostics · 2015 · Recalled
  19. 3 generations backK163077 LOGIQ E9, LOGIQ E9 XDClear 2.0GE Medical Systems Ultrasound and Primary Care Diagnostics · 2016
  20. 2 generations backK173555 Logiq E10GE Healthcare · 2017 · Recalled
  21. 1 generation backK200158 Logiq E10GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · 2020
  22. This deviceK211488 Logiq E10GE Healthcare · 2021

Showing 5 of 11 descendants. See all descendants

Descendants cleared per year

2022: 12023: 12024: 32025: 32026: 3
2022high 3 (2024) · low 1 (2022)2026

Most influential descendants

Showing 5 of 11 · See all
  • K231966Logiq E10GE Medical Systems Ultrasound and Primary Care Diagnostics · 2023 · cites it directly5descendants
  • K220940EchoPAC Software Only, EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics · 2022 · cites it directly2descendants
  • K251342EchoPAC Software Only / EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics · 2025 · 2 generations on1descendant
  • K242168Voluson Expert 18; Voluson Expert 20; Voluson Expert 22GE Medical Systems Ultrasound and Primary Care Diagnostics · 2024 · cites it directly1descendant
  • K261623EchoPAC Software Only / EchoPAC Plug-in (v211)GE Medical Systems Ultrasound and Primary Care Diagnostics · 2026 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−21K935595Acuson Model 3001Acuson Corp.1995—
−20K973767Harmonic Imaging with ContrastAcuson Corp.1997—
−19K022567Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp.2002—
−18K032114Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc.2003—
−17K041319Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc.2004—
−16K042770Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20041
−15K050240Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20051
−14K052894Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc.20051
−13K063138Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc.2006—
−12K063803Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI20079
−11K072786Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc.2007—
−10K083095Sonixtouch Ultrasound SystemUltrasonix Medical Corporation2008—
−9K092271GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4GE Healthcare20091
−8K110943Logiq E9GE Healthcare20112
−7K113690GE Logiq I, Logiq E and Vivid EGE Healthcare20111
−6K123564Logiq E9 Diagnostic Ultrasound SystemGE Healthcare20121
−5K131514GE Vivid E9 Diagnostic Ultrasound Imaging SystemGe Vingmed Ultrasound AS20132
−4K152309LOGIQ E9, LOGIQ E9 XDClear 2.0GE Medical Systems Ultrasound and Primary Care Diagnostics20151
−3K163077LOGIQ E9, LOGIQ E9 XDClear 2.0GE Medical Systems Ultrasound and Primary Care Diagnostics2016—
−2K173555Logiq E10GE Healthcare20172
−1K200158Logiq E10GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC2020—
0 (this device)K211488Logiq E10GE Healthcare2021—
+1K231966Logiq E10GE Medical Systems Ultrasound and Primary Care Diagnostics2023—
+1K220940EchoPAC Software Only, EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics2022—
+2K251342EchoPAC Software Only / EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics2025—
+1K242168Voluson Expert 18; Voluson Expert 20; Voluson Expert 22GE Medical Systems Ultrasound and Primary Care Diagnostics2024—
+3K261623EchoPAC Software Only / EchoPAC Plug-in (v211)GE Medical Systems Ultrasound and Primary Care Diagnostics2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198910
199210
199440
199550
199610
199760
199820
199970
200070
200170
2002110
2003120
2004140
2005100
200680
200750
200850
200950
201070
201130
201270
201320
201410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202310
202430
202530
202630
FIG. 1 — Lineage of K211488, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYN device

  1. #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K200158Logiq E10
Summary page 4
…stem, 21CFR 892.1560, 90- IYO Diagnostic Ultrasound Transducer, 21 CFR 892.1570, 90-ITX Primary Predicate Device: K200158 LOGIQ E10 Diagnostic Ultrasound System Reference Device(s): Vivid E95 K202658 Diagnostic Ultrasound System Device…
GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC2020—
†K202658Vivid E80/ Vivid E90/ Vivid E95GE Medical Systems Ultrasound and Primary Care Diagnostics2021—

What descends from it? (11)

See all 11

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K231966Logiq E10GE Medical Systems Ultrasound and Primary Care Diagnostics20235
K220940EchoPAC Software Only, EchoPAC Plug-inGE Medical Systems Ultrasound and Primary Care Diagnostics20222
K242168Voluson Expert 18; Voluson Expert 20; Voluson Expert 22GE Medical Systems Ultrasound and Primary Care Diagnostics20241

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 8 companies; a new generation was cleared every 12 months on median.
  • 50 of the 153 ancestors have a recall of any class.
  • Of its descendants, K231966 (GE Medical Systems Ultrasound and Primary Care Diagnostics, 2023) has gone furthest, with 5 descendants of its own.

How does its category compare?

All IYN devices

IYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · IYN

57in 2025

2007: 132008: 252009: 182010: 292011: 392012: 432013: 512014: 562015: 542016: 602017: 642018: 592019: 472020: 572021: 462022: 532023: 442024: 502025: 572026 (partial year): 44
2007high 64 (2017) · low 13 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYN

124in 2025

2007: 26 days median2008: 18 days median2009: 29 days median2010: 67 days median2011: 46 days median2012: 37 days median2013: 60 days median2014: 39 days median2015: 55 days median2016: 56 days median2017: 83 days median2018: 85 days median2019: 79 days median2020: 72 days median2021: 105 days median2022: 105 days median2023: 115 days median2024: 119 days median2025: 124 days median2026 (partial year): 107 days median
2007high 124 (2025) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYN

10in 2025

2007: 162008: 122009: 82010: 102011: 82012: 32013: 82014: 22015: 32016: 22018: 72020: 42021: 82022: 102023: 42024: 12025: 102026 (partial year): 2, 1 Class I
2007high 16 (2007) · low 0 (2017)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · IYN

610in 2025

2007: 32008: 22009: 92010: 172011: 182012: 202013: 182014: 482015: 1162016: 1452017: 1462018: 852019: 592020: 672021: 2132022: 1862023: 2292024: 2662025: 610
2007high 610 (2025) · low 2 (2008)2025

MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071326163
20082518122
2009182989
201029671017
20113946818
20124337320
20135160818
20145639248
201554553116
201660562145
201764830146
20185985785
20194779059
20205772467
2021461058213
20225310510186
2023441154229
2024501191266
20255712410610
2026441072 (1)—

What is it indicated for?

LOGIQ E10 is intended for use by a qualified physician for ultrasound evaluation of Fetal / Obstetrics; Abdominal (including Renal, Gynecology/Pelvic); Pediatric; Small Organ (Breast, Testes, Thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (Adult and Pediatric); Peripheral Vascular; Musculo-skeletal Conventional and Superficial; Urology (including Prostate); Transrectal; Transvaginal; Transesophageal and Intraoperative (Abdominal and Vascular).…

Read the full statement (104 words)

LOGIQ E10 is intended for use by a qualified physician for ultrasound evaluation of Fetal / Obstetrics; Abdominal (including Renal, Gynecology/Pelvic); Pediatric; Small Organ (Breast, Testes, Thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (Adult and Pediatric); Peripheral Vascular; Musculo-skeletal Conventional and Superficial; Urology (including Prostate); Transrectal; Transvaginal; Transesophageal and Intraoperative (Abdominal and Vascular).

Modes of operation include: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded Pulse, 3D/4D Imaging mode, Elastography, Shear Wave Elastography, Attenuation Imaging and Combined modes: B/M, B/Color, B/PWD, B/Color/PWD, B/Power/PWD. The LOGIQ E10 is intended to be used in a hospital or medical clinic.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K211488: Logiq E10.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K211488

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026