510(k) · Cleared
ClearedInfrascanner
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Infrascan, Inc. · OPT Infrared Hematoma Detector
Cleared on Feb 9, 2022 as substantially equivalent to K120949 (Infrascan, Inc., 2013) and 1 other predicate after a 259-day review. Its family tree reaches back 3 generations to 2011. 1 later device descends from it.
- Decided
- Feb 9, 2022
- Review
- 259 days
- Class
- Class II
- Product code
- OPT
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 3 generations to DEN100002 (2011). 1 later device descends from it, 1 citing it directly.
- Root · 3 generations backDEN100002 Infrascanner, Model 1000Infrascan, Inc. · 2011
- 2 generations backK120949 InfrascannerInfrascan, Inc. · 2013
- 1 generation backK200203 InfrascannerInfrascan, Inc. · 2020
- This deviceK211617 InfrascannerInfrascan, Inc. · 2022
- Descendant · cites it directly · 0 of its ownK241389 Infrascanner Model 2500 (Model 2500)Infrascan, Inc. · 2024
Most influential descendants
Showing 1 of 1 · See all- K241389Infrascanner Model 2500 (Model 2500)Infrascan, Inc. · 2024 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | DEN100002 | Infrascanner, Model 1000 | Infrascan, Inc. | 2011 | — |
| −2 | K120949 | Infrascanner | Infrascan, Inc. | 2013 | — |
| −1 | K200203 | Infrascanner | Infrascan, Inc. | 2020 | — |
| 0 (this device) | K211617 | Infrascanner | Infrascan, Inc. | 2022 | — |
| +1 | K241389 | Infrascanner Model 2500 (Model 2500) | Infrascan, Inc. | 2024 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OPT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OPT device
- #1 K241389 Infrascanner Model 2500 (Model 2500)score 9.4 · 4 generations · no Class I recall
- #2 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K120949 | InfrascannerSummary page 4…sual Near Infrared (NIR) Brain Hematoma Detector Name Classification Name OPT (21 C.F.R. §882.1935) Predicate Devices InfraScan Infrascanner K120949 (Model 2000) and K200203 (Model 2500) The Infrascanner is indicated for the detection of traumatic supraten… | 2013 |
| * | K200203 | InfrascannerSummary page 4…Near Infrared (NIR) Brain Hematoma Detector Name Classification Name OPT (21 C.F.R. §882.1935) Predicate Devices InfraScan Infrascanner K120949 (Model 2000) and K200203 (Model 2500) The Infrascanner is indicated for the detection of traumatic supratentorial hematomas of as sm… | 2020 |
| † | K080377 | Infrascanner |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K241389 | Infrascanner Model 2500 (Model 2500) | 2024 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 11 years and passes through 1 company; a new generation was cleared every 1.6 years on median.
- None of the 3 ancestors has a recall.
- Of its descendants, K241389 (Infrascan, Inc., 2024) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K120949.
How does its category compare?
All OPT devicesOPT Infrared Hematoma Detector: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · OPT
1in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · OPT
Too few OPT 510(k)s in any year since 2007 to give a median.
Recalls per year · OPT
1in 2013
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OPT
2in 2013
MAUDE reports naming product code OPT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 1 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 1 | — | 1 | 2 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 1 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 1 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 1 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Infrascanner is indicated for the detection of traumatic supratentorial hematomas of as small as 3.5mL and as deep as 2.5 cm from brain surface, but not both at the same time, as an adjunctive device to the clinical evaluation in the acute hospital setting of adult patients and pediatric patients aged 2 years and older with suspected traumatic supratentorial intracranial hematoma. The device is indicated to assess patients for CT scans but should not…
Read the full statement (126 words)
The Infrascanner is indicated for the detection of traumatic supratentorial hematomas of as small as 3.5mL and as deep as 2.5 cm from brain surface, but not both at the same time, as an adjunctive device to the clinical evaluation in the acute hospital setting of adult patients and pediatric patients aged 2 years and older with suspected traumatic supratentorial intracranial hematoma. The device is indicated to assess patients for CT scans but should not serve as a substitute for these scans, the device should only be used to rule in subjects for the presence of hematoma, never to rule out. The Infrascanner is indicated for use by Physicians, or under the direction of a physician, who has been trained in the use of the device.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K211617 · printed Nov 4, 2026
Cite this page
510(k) Report. “K211617: Infrascanner.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K211617
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026