510(k) Report

510(k) · Cleared

Cleared

KardiaMobile Card

K211668510(k) SpecialCleared Nov 30, 2021182-day reviewClass II21 CFR 870.2920

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

AliveCor, Inc. · DXH Transmitters And Receivers, Electrocardiograph, Telephone

Cleared on Nov 30, 2021 as substantially equivalent to K191406 (AliveCor, Inc., 2020) after a 182-day review. Its family tree reaches back 2 generations to 2018.

Decided
Nov 30, 2021
Review
182 days
Class
Class II
Product code
DXH
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to DEN180044 (2018). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2019: 1 other ancestorReference device: K183319 · Triangle System · AliveCor, Inc. · 2019DEN180044 · ECG App · Apple, Inc. · 2018K191406 · KardiaMobile, KardiaStation · AliveCor, Inc. · 20202016201820202022
Other ancestors, by generation 2 generations back: 1 other ancestor K191406 · KardiaMobile, KardiaStation · AliveCor, Inc. · 2020DEN180044 · ECG App · Apple, Inc. · 20180
  1. Root · 2 generations backDEN180044 ECG AppApple, Inc. · 2018
  2. 1 generation backK191406 KardiaMobile, KardiaStationAliveCor, Inc. · 2020
  3. This deviceK211668 KardiaMobile CardAliveCor, Inc. · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2DEN180044ECG AppApple, Inc.2018—
−1K191406KardiaMobile, KardiaStationAliveCor, Inc.2020—
0 (this device)K211668KardiaMobile CardAliveCor, Inc.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201910
FIG. 1 — Lineage of K211668, 2018–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXH device

  1. #1 K243438 MEMO Patch M (MPT-E08R-UNC01)score 12.9 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K191406KardiaMobile, KardiaStation
Summary page 4
…Telephone electrocardiograph transmitter and receiver, Class II Product Code: DXH, DPS, QDA Establishment Registration: 3009715978 PREDICATE DEVICE(S) [807.92(a)(3)] K191406 – AliveCor KardiaMobile System (Primary predicate) K183319 – AliveCor Triangle System (Reference device)…
AliveCor, Inc.2020—
†K183319Triangle SystemAliveCor, Inc.2019—

Also cleared against K191406: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 2 companies; a new generation was cleared every 1.9 years on median.
  • None of the 3 ancestors has a recall.
  • 1 other device also cites its predicate K191406.

How does its category compare?

All DXH devices

DXH Transmitters And Receivers, Electrocardiograph, Telephone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · DXH

4in 2025

2007: 32008: 72009: 22010: 22012: 12013: 32014: 62015: 42016: 12017: 52018: 42019: 62020: 52021: 32022: 42023: 12025: 42026 (partial year): 1
2007high 7 (2008) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXH

322in 2025

2007: 202 days median2008: 41 days median2013: 206 days median2014: 186 days median2015: 142 days median2017: 150 days median2018: 294 days median2019: 177 days median2020: 141 days median2021: 107 days median2022: 150 days median2025: 322 days median
2007high 322 (2025) · low 41 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXH

1in 2015

2008: 42011: 32015: 12026 (partial year): 1
2007high 4 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXH

27in 2025

2009: 12010: 42011: 12012: 12013: 12014: 12016: 52017: 42020: 52021: 22022: 62023: 42024: 22025: 27
2007high 27 (2025) · low 0 (2007)2025

MAUDE reports naming product code DXH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007320200
200874140
20092—01
20102—04
20110—31
20121—01
2013320601
2014618601
2015414210
20161—05
2017515004
2018429400
2019617700
2020514105
2021310702
2022415006
20231—04
20240—02
20254322027
20261—1—

What is it indicated for?

The KardiaMobile Card System is intended to record, store and transfer single-channel electrocardiogram (ECG) rhythms.

The KardiaMobile Card System also displays ECG rhythms and output of ECG analysis from AliveCor’s KardiaAI platform including detecting the presence of normal sinus rhythm, atrial fibrillation, bradycardia, tachycardia, and others.

The KardiaMobile Card System is intended for use by healthcare professionals, patients with known or suspected heart conditions and health-conscious individuals. The device has not been tested and is not intended for pediatric use.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K211668: KardiaMobile Card.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K211668

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026