510(k) Report

510(k) · Cleared

Cleared

ELEOS Limb Salvage System

K211677510(k) TraditionalCleared Jul 28, 202157-day reviewClass II21 CFR 888.3510

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Onkos Surgical · KRO Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer

Cleared on Jul 28, 2021 as substantially equivalent to K161520 (Onkos Surgical, Inc., 2016) and 1 other predicate after a 57-day review. Its family tree reaches back 2 generations to 1987.

Decided
Jul 28, 2021
Review
57 days
Class
Class II
Product code
KRO
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K870730 (1987). 14 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2016: 1 other ancestor2001: 1 other ancestor2000: 1 other ancestor1998: 1 other ancestor1997: 3 other ancestors1994: 2 other ancestors1993: 1 other ancestor1991: 1 other ancestor1990: 1 other ancestorK870730 · Noiles Total Knee Prosthesis · Joint Medical Products Corp. · 1987K003182 · Orthogenesis LPS System · Depuy, Inc. · 20011990200020102020
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 11 other ancestors K003182 · Orthogenesis LPS System · Depuy, Inc. · 2001K870730 · Noiles Total Knee Prosthesis · Joint Medical Products Corp. · 19870
  1. Root · 2 generations backK870730 Noiles Total Knee ProsthesisJoint Medical Products Corp. · 1987
  2. 1 generation backK003182 Orthogenesis LPS SystemDepuy, Inc. · 2001
  3. This deviceK211677 ELEOS Limb Salvage SystemOnkos Surgical · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K870730Noiles Total Knee ProsthesisJoint Medical Products Corp.1987—
−1K003182Orthogenesis LPS SystemDepuy, Inc.2001—
0 (this device)K211677ELEOS Limb Salvage SystemOnkos Surgical2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199110
199310
199420
199730
199810
200010
200110
201610
FIG. 1 — Lineage of K211677, 1987–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KRO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KRO device

  1. #1 K251665 Triathlon® Hinge Knee Systemscore 19.0 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K161520ELEOS Limb Salvage System
Summary page 4
…cemented Regulatory Class: II Product Code(s): KRO JDI JWH LPH LZO 5.3. Predicate Device ELEOS™ Limb Salvage System, Onkos Surgical, Inc., K161520 (Primary Predicate) Orthogenesis LPS System, DePuy, Inc., K003182 (Predicate) 5.4. Device Description The Onkos Surgical ELEOS…
Onkos Surgical, Inc.201611
*K003182Orthogenesis LPS System
Summary page 4
…KRO JDI JWH LPH LZO 5.3. Predicate Device ELEOS™ Limb Salvage System, Onkos Surgical, Inc., K161520 (Primary Predicate) Orthogenesis LPS System, DePuy, Inc., K003182 (Predicate) 5.4. Device Description The Onkos Surgical ELEOS™ Limb Salvage System consists of components that are used in the…
Depuy, Inc.2001—

Also cleared against K161520: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 3 companies; a new generation was cleared every 20.1 years on median.
  • 4 of the 14 ancestors have a recall of any class.
  • 5 other devices also cite its predicate K161520.

How does its category compare?

All KRO devices

KRO Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · KRO

3in 2025

2007: 12008: 32009: 32010: 12011: 22012: 22013: 32014: 22015: 62016: 32017: 12019: 32020: 12021: 32022: 12023: 42024: 32025: 32026 (partial year): 1
2007high 6 (2015) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KRO

56in 2025

2008: 126 days median2009: 86 days median2013: 189 days median2015: 113 days median2016: 148 days median2019: 244 days median2021: 57 days median2023: 148 days median2024: 87 days median2025: 56 days median
2007high 244 (2019) · low 56 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KRO

14so far in 2026, the most since 2007

2007: 12008: 32009: 82011: 12012: 12013: 22015: 12016: 52017: 42018: 12021: 12025: 12026 (partial year): 14
2007high 14 (2026) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KRO

915in 2025

2007: 372008: 442009: 662010: 1102011: 1192012: 1732013: 1942014: 4062015: 3332016: 3692017: 5432018: 6142019: 7592020: 7492021: 7702022: 8922023: 7462024: 8552025: 915
2007high 915 (2025) · low 37 (2007)2025

MAUDE reports naming product code KRO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—137
20083126344
2009386866
20101—0110
20112—1119
20122—1173
201331892194
20142—0406
201561131333
201631485369
20171—4543
20180—1614
201932440759
20201—0749
20213571770
20221—0892
202341480746
20243870855
20253561915
20261—14—

What is it indicated for?

The ELEOS™ Limb Salvage System is indicated for resection and replacement of the proximal femur, intercalary portion of the femur, total femur, distal femur, and proximal tibia in skeletally mature patients with the following conditions: 1) Non-inflammatory degenerative joint disease such as osteoarthritis, traumatic arthritis, avascular necrosis, ankylosis, protrusion acetabuli, and painful hip dysplasia; 2) Inflammatory degenerative joint disease such…

Read the full statement (166 words)

The ELEOS™ Limb Salvage System is indicated for resection and replacement of the proximal femur, intercalary portion of the femur, total femur, distal femur, and proximal tibia in skeletally mature patients with the following conditions:

1) Non-inflammatory degenerative joint disease such as osteoarthritis, traumatic arthritis, avascular necrosis, ankylosis, protrusion acetabuli, and painful hip dysplasia;

2) Inflammatory degenerative joint disease such as rheumatoid arthritis;

3) Correction of functional deformity

4) Revision procedures where other treatments or devices have failed; and,

5) Treatment of fractures that are unmanageable using other techniques.

The ELEOS Limb Salvage System is also indicated for procedures where resection and replacement of the proximal femur, intercalary portion of the femur, total femur, distal femur, and proximal tibia is required with the following conditions:

1) Patients suffering from severe arthropathy of the hip and/or knee that does not respond to any conservative therapy or better alternative surgical treatment;

2) Surgical intervention for severe trauma, revision hip or knee arthroplasties, and/or Oncology indications.

3) Metastatic diseases

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K211677: ELEOS Limb Salvage System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K211677

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026