510(k) Report

510(k) · Cleared

Cleared

Planmed Clarity 2D, Planmed Clarify S

K211720510(k) TraditionalCleared Jul 18, 2022409-day reviewClass II21 CFR 892.1715

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Planmed OY · MUE Full Field Digital, System, X-Ray, Mammographic

Cleared on Jul 18, 2022 as substantially equivalent to K192317 (Planmed OY, 2020) after a 409-day review. Its family tree reaches back 4 generations to 2004.

Decided
Jul 18, 2022
Review
409 days
Class
Class II
Product code
MUE
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to P030010 (2004). No later device cites it as a predicate yet.

  1. Root · 4 generations backP030010 Siemens Mammomat Novationdr Full Field Digital Mammography SystemSiemens Medical Solution · 2004 · Recalled
  2. 3 generations backK111361 Planmed Nuance ExcelPlanmeca USA, Inc. · 2011
  3. 2 generations backK163328 Planmed ClarityPlanmed OY · 2017
  4. 1 generation backK192317 Planmed Clarity 2D and Clarity SPlanmed OY · 2020
  5. This deviceK211720 Planmed Clarity 2D, Planmed Clarify SPlanmed OY · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4P030010Siemens Mammomat Novationdr Full Field Digital Mammography SystemSiemens Medical Solution20042
−3K111361Planmed Nuance ExcelPlanmeca USA, Inc.2011—
−2K163328Planmed ClarityPlanmed OY2017—
−1K192317Planmed Clarity 2D and Clarity SPlanmed OY2020—
0 (this device)K211720Planmed Clarity 2D, Planmed Clarify SPlanmed OY2022—
FIG. 1 — Lineage of K211720, 2004–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MUE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MUE device

  1. #1 K253678 MAMMOMAT B.brilliant (11372950)score 13.6 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192317Planmed Clarity 2D and Clarity S
Summary page 4
…Class: II Product Code: MUE III. PREDICATE DEVICE Planmed Clarity Full Field Digital Mammography X-ray System, #K192317 This predicate system has not been subject to a design-related recall. No reference devices were used in this submi…
Planmed OY2020—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 3 companies; a new generation was cleared every 6.3 years on median.
  • 1 of the 4 ancestors has a recall of any class.

How does its category compare?

All MUE devices

MUE Full Field Digital, System, X-Ray, Mammographic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · MUE

3in 2025

2007: 62008: 52009: 82010: 102011: 102012: 42013: 72014: 12015: 12016: 12017: 82018: 22019: 22020: 42021: 42022: 32023: 12024: 12025: 32026 (partial year): 4
2007high 10 (2010) · low 1 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MUE

255in 2025

2011: 192 days median2012: 123 days median2013: 207 days median2017: 95 days median2020: 188 days median2021: 164 days median2022: 404 days median2025: 255 days median2026 (partial year): 185 days median
2007high 404 (2022) · low 95 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MUE

4in 2025

2008: 12009: 12010: 22011: 52014: 22017: 62018: 12019: 12023: 12025: 42026 (partial year): 1
2007high 6 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MUE

40in 2025

2008: 42009: 32010: 22011: 102012: 62013: 112014: 72015: 62016: 192017: 1152018: 1452019: 802020: 492021: 252022: 362023: 292024: 332025: 40
2007high 145 (2018) · low 0 (2007)2025

MAUDE reports naming product code MUE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076—00
20085—14
20098—13
201010—22
201110192510
2012412306
20137207011
20141—27
20151—06
20161—019
20178956115
20182—1145
20192—180
20204188049
20214164025
20223404036
20231—129
20241—033
20253255440
202641851—

What is it indicated for?

The Planmed Clarity 2D and S mammography units acquire digital 2D mammographic images. Both systems are intended to be used for screening and diagnosis of breast cancer. The Clarity 2D and S systems may also be used for additional diagnostic workup of the breast. Additionally, the Planmed Clarity 2D and S systems can be used to provide digital x-ray images of breast biopsy specimens.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K211720: Planmed Clarity 2D, Planmed Clarify S.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K211720

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026