LifePath Remote Patient Monitoring Platform

K211822510(k) TraditionalCleared Feb 3, 2022234-day reviewClass II21 CFR 870.2910

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Elastic Care Incorporated · DRG Transmitters And Receivers, Physiological Signal, Radiofrequency

Cleared on Feb 3, 2022 as substantially equivalent to K181248 (Comarch Healthcare SA, 2018) after a 234-day review. Its family tree reaches back 18 generations to 1987. 1 later device descends from it.

Decided
Feb 3, 2022
Review
234 days
Class
Class II
Product code
DRG
Recalls
None
Predicates
1

Its longest line of descent runs back 18 generations to K864318 (1987). 74 ancestors in all, the oldest K790130 (1979). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2013: 1 other ancestor2012: 1 other ancestor2011: 1 other ancestor2009: 1 other ancestor2010: 1 other ancestor2007: 2 other ancestors2005: 3 other ancestors2004: 5 other ancestors2003: 3 other ancestors2001: 4 other ancestors2006: 4 other ancestors1999: 5 other ancestors1998: 5 other ancestors1996: 2 other ancestors1979: 1 other ancestor2002: 2 other ancestors2000: 2 other ancestors1997: 2 other ancestors1995: 3 other ancestors1993: 2 other ancestors1988: 1 other ancestor1987: 2 other ancestors1990: 1 other ancestor1992: 1 other ancestor1991: 1 other ancestor2025: 1 descendant clearedK864318 · The Buddy System/Health Information System · The Buddy Systems, Inc. · 1987K952979 · Hanc Network · Healthtech Services Corp. · 1996K964408 · Poseidon Cardiac Monitoring System (PCMS) · Instromedix, Inc. · 1997K993169 · Modification of: Physiological Signal Transmitter and Receiver, Model 3810A · Hewlett-Packard Co. · 1999K023749 · The M3810A Philips Telemonitoring System with M3812B Telestation (M310A/12B) · Philips Medical Systems · 2002K031840 · Carematix Wellness System · Carematix, Inc. · 2003×2: 2 generations cleared close together, K040966 (2004), K042273 (2004) K050567 · Health Buddy Appliance · Health Hero Network, Inc. · 2005K060843 · Modification to Health Buddy Appliance · Health Hero Network, Inc. · 2006K063612 · Modification to Health Buddy Appliance · Health Hero Network, Inc. · 2006×2: 2 generations cleared close together, K080798 (2008), K083115 (2008) K101178 · Modification to Intel Health Guide PHS6000 · Intel Corp. · 2010K103276 · Intel Health Guide · Intel Corporation Digital Health Group · 2011K122285 · Tablet Commander · Cardiocom, LLC · 2012K133252 · Healthinterlink Beacon · Healthinterlink, LLC · 2014K181248 · Comarch e-Care Platform · Comarch Healthcare SA · 201819801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor3 generations back: 3 other ancestors4 generations back: 8 other ancestors5 generations back: 14 other ancestors6 generations back: 18 other ancestors7 generations back: 9 other ancestors8 generations back: 1 other ancestor9 generations back: 2 other ancestors 1 generation forward: 1 descendant K181248 · Comarch e-Care Platform · Comarch Healthcare SA · 2018K133252 · Healthinterlink Beacon · Healthinterlink, LLC · 2014K122285 · Tablet Commander · Cardiocom, LLC · 2012K103276 · Intel Health Guide · Intel Corporation Digital Health Group · 2011K101178 · Modification to Intel Health Guide PHS6000 · Intel Corp. · 2010K083115 · Modification to Intel Health Guide, Model PHS6000 · Intel Corp. · 2008K080798 · Intel Health Guide, Model: PHS6000 · Intel Corp. · 2008K063612 · Modification to Health Buddy Appliance · Health Hero Network, Inc. · 2006K060843 · Modification to Health Buddy Appliance · Health Hero Network, Inc. · 2006K050567 · Health Buddy Appliance · Health Hero Network, Inc. · 2005K042273 · Modification to Health Buddy with Device Connectivity · Health Hero Network, Inc. · 2004K040966 · Modification to Carematix Wellness System · Carematix, Inc. · 2004K031840 · Carematix Wellness System · Carematix, Inc. · 2003K023749 · The M3810A Philips Telemonitoring System with M3812B Telestation (M310A/12B) · Philips Medical Systems · 2002K993169 · Modification of: Physiological Signal Transmitter and Receiver, Model 3810A · Hewlett-Packard Co. · 1999K964408 · Poseidon Cardiac Monitoring System (PCMS) · Instromedix, Inc. · 1997K952979 · Hanc Network · Healthtech Services Corp. · 1996K864318 · The Buddy System/Health Information System · The Buddy Systems, Inc. · 1987−15−10−50
  1. Root · 18 generations backK864318 The Buddy System/Health Information SystemThe Buddy Systems, Inc. · 1987
  2. 14 generations between
  3. 3 generations backK122285 Tablet CommanderCardiocom, LLC · 2012
  4. 2 generations backK133252 Healthinterlink BeaconHealthinterlink, LLC · 2014
  5. 1 generation backK181248 Comarch e-Care PlatformComarch Healthcare SA · 2018
  6. This deviceK211822 LifePath Remote Patient Monitoring PlatformElastic Care Incorporated · 2022
  7. Descendant · cites it directly · 0 of its ownK252440 EasyTeleMed (2.0.2)Ingeniars S.R.L. · 2025
Show all 18 generations
  1. Root · 18 generations backK864318 The Buddy System/Health Information SystemThe Buddy Systems, Inc. · 1987
  2. 17 generations backK952979 Hanc NetworkHealthtech Services Corp. · 1996
  3. 16 generations backK964408 Poseidon Cardiac Monitoring System (PCMS)Instromedix, Inc. · 1997
  4. 15 generations backK993169 Modification of: Physiological Signal Transmitter and Receiver…Hewlett-Packard Co. · 1999
  5. 14 generations backK023749 The M3810A Philips Telemonitoring System with M3812B Telestation…Philips Medical Systems · 2002
  6. 13 generations backK031840 Carematix Wellness SystemCarematix, Inc. · 2003
  7. 12 generations backK040966 Modification to Carematix Wellness SystemCarematix, Inc. · 2004
  8. 11 generations backK042273 Modification to Health Buddy with Device ConnectivityHealth Hero Network, Inc. · 2004
  9. 10 generations backK050567 Health Buddy ApplianceHealth Hero Network, Inc. · 2005
  10. 9 generations backK060843 Modification to Health Buddy ApplianceHealth Hero Network, Inc. · 2006
  11. 8 generations backK063612 Modification to Health Buddy ApplianceHealth Hero Network, Inc. · 2006
  12. 7 generations backK080798 Intel Health Guide, Model: PHS6000Intel Corp. · 2008
  13. 6 generations backK083115 Modification to Intel Health Guide, Model PHS6000Intel Corp. · 2008
  14. 5 generations backK101178 Modification to Intel Health Guide PHS6000Intel Corp. · 2010
  15. 4 generations backK103276 Intel Health GuideIntel Corporation Digital Health Group · 2011
  16. 3 generations backK122285 Tablet CommanderCardiocom, LLC · 2012
  17. 2 generations backK133252 Healthinterlink BeaconHealthinterlink, LLC · 2014
  18. 1 generation backK181248 Comarch e-Care PlatformComarch Healthcare SA · 2018
  19. This deviceK211822 LifePath Remote Patient Monitoring PlatformElastic Care Incorporated · 2022

Most influential descendants

Showing 1 of 1 · See all
  • K252440EasyTeleMed (2.0.2)Ingeniars S.R.L. · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−18K864318The Buddy System/Health Information SystemThe Buddy Systems, Inc.1987—
−17K952979Hanc NetworkHealthtech Services Corp.1996—
−16K964408Poseidon Cardiac Monitoring System (PCMS)Instromedix, Inc.1997—
−15K993169Modification of: Physiological Signal Transmitter and Receiver, Model 3810AHewlett-Packard Co.1999—
−14K023749The M3810A Philips Telemonitoring System with M3812B Telestation (M310A/12B)Philips Medical Systems2002—
−13K031840Carematix Wellness SystemCarematix, Inc.2003—
−12K040966Modification to Carematix Wellness SystemCarematix, Inc.2004—
−11K042273Modification to Health Buddy with Device ConnectivityHealth Hero Network, Inc.2004—
−10K050567Health Buddy ApplianceHealth Hero Network, Inc.2005—
−9K060843Modification to Health Buddy ApplianceHealth Hero Network, Inc.2006—
−8K063612Modification to Health Buddy ApplianceHealth Hero Network, Inc.2006—
−7K080798Intel Health Guide, Model: PHS6000Intel Corp.2008—
−6K083115Modification to Intel Health Guide, Model PHS6000Intel Corp.2008—
−5K101178Modification to Intel Health Guide PHS6000Intel Corp.2010—
−4K103276Intel Health GuideIntel Corporation Digital Health Group2011—
−3K122285Tablet CommanderCardiocom, LLC2012—
−2K133252Healthinterlink BeaconHealthinterlink, LLC2014—
−1K181248Comarch e-Care PlatformComarch Healthcare SA2018—
0 (this device)K211822LifePath Remote Patient Monitoring PlatformElastic Care Incorporated2022—
+1K252440EasyTeleMed (2.0.2)Ingeniars S.R.L.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198720
198810
199010
199110
199210
199320
199530
199620
199720
199850
199950
200020
200140
200220
200330
200450
200530
200640
200720
200910
201010
201110
201210
201310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K211822, 1987–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DRG device

  1. #1 K223711 ANNE Onescore 20.8 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K181248Comarch e-Care Platform
Summary page 5
…LifePath Remote Patient Monitoring Platform 4 LEGALLY MARKETED PREDICATE DEVICE(S) Predicate Device: Comarch e-Care Platform, K181248 5 DEVICE DESCRIPTION The LifePath Remote Patient Monitoring Platform (the “LifePath RPM Platform”) is a software applicat…
Comarch Healthcare SA2018—

Also cleared against K181248: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K252440EasyTeleMed (2.0.2)Ingeniars S.R.L.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 35 years and passes through 13 companies; a new generation was cleared every 1.5 years on median.
  • 6 of the 74 ancestors have a recall of any class.
  • Of its descendants, K252440 (Ingeniars S.R.L., 2025) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K181248.

How does its category compare?

All DRG devices

DRG Transmitters And Receivers, Physiological Signal, Radiofrequency: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · DRG

3in 2025

2007: 62008: 52009: 132010: 102011: 92012: 122013: 132014: 102015: 22016: 22017: 72018: 62019: 52020: 62021: 22022: 62023: 42024: 32025: 32026 (partial year): 2
2007high 13 (2009) · low 2 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRG

127in 2025

2007: 63 days median2008: 74 days median2009: 94 days median2010: 68 days median2011: 104 days median2012: 103 days median2013: 146 days median2014: 177 days median2017: 98 days median2018: 220 days median2019: 122 days median2020: 159 days median2022: 287 days median2023: 212 days median2024: 125 days median2025: 127 days median
2007high 287 (2022) · low 63 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DRG

3in 2007

2007: 32026 (partial year): 1
2007high 3 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DRG

52in 2025

2007: 142008: 92009: 52010: 132011: 122012: 92013: 132014: 972015: 1312016: 1822017: 4842018: 1662019: 702020: 822021: 1072022: 432023: 192024: 262025: 52
2007high 484 (2017) · low 5 (2009)2025

MAUDE reports naming product code DRG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007663314
200857409
2009139405
20101068013
20119104012
20121210309
201313146013
201410177097
20152—0131
20162—0182
20177980484
201862200166
20195122070
20206159082
20212—0107
20226287043
20234212019
20243125026
20253127052
20262—1—

What is it indicated for?

The LifePath Remote Patient Monitoring Platform connects with compatible physiological measurement devices (blood pressure meters, pulse oximeters, thermometers, glucometers) to collect vital sign using a Patient App and securely transmit them, unaltered, to LifePath servers. The LifePath Platform is intended to be used at home or in healthcare-related environments such as long-term care facilities or clinics, nursing homes and hospitals. The LifePath…

Read the full statement (249 words)

The LifePath Remote Patient Monitoring Platform connects with compatible physiological measurement devices (blood pressure meters, pulse oximeters, thermometers, glucometers) to collect vital sign using a Patient App and securely transmit them, unaltered, to LifePath servers. The LifePath Platform is intended to be used at home or in healthcare-related environments such as long-term care facilities or clinics, nursing homes and hospitals. The LifePath Remote Patient Monitoring Platform serves as Software as a Medical Device and can be used only with specific FDA cleared third-party measurement devices.

The LifePath Remote Patient Monitoring Platform securely stores the collected information on LifePath servers and make it available for viewing by remotely located clinicians using a Clinician App installed on their smartphones. The clinician can analyze the data, prescribe medications or contact the patient if needed. Clinicians can set thresholds individually for each patient; notifications are sent to the clinician for threshold breaches.

The LifePath Platform does not interpret, make diagnoses or serve as a substitute for medical care. It is not intended to provide real time data.

The LifePath Platform is contraindicated for use in high-acuity environments, such as the ICU or operating rooms, and is not intended for use on acutely or critically ill patients or those requiring time-critical or emergency intervention. It is intended for patients who are willing and capable of managing its use or where its operations can be performed by a caregiver. Clinical judgment and experience of a Clinician are required to check and interpret the information delivered.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K211822: LifePath Remote Patient Monitoring Platform.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K211822

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026