510(k) · Cleared
ClearedSegment 3DPrint
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medviso AB · LLZ System, Image Processing, Radiological
Cleared on May 6, 2022 as substantially equivalent to K183105 (Materialise NV, 2019) after a 316-day review. Its family tree reaches back 5 generations to 1993.
- Decided
- May 6, 2022
- Review
- 316 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 5 generations to K924630 (1993). 6 ancestors in all, the oldest K924810 (1993). No later device cites it as a predicate yet.
- Root · 5 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
- 4 generations backK970617 CT-Modeller SystemMaterialise NV · 1997
- 3 generations backK033849 Simplant SystemMaterialise NV · 2004
- 2 generations backK073468 MimicsMaterialise NV · 2008
- 1 generation backK183105 Mimics MedicalMaterialise NV · 2019
- This deviceK211966 Segment 3DPrintMedviso AB · 2022
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K924630 | Surgicad (TM) View (TM) | Surgicad Corp. | 1993 | — |
| −4 | K970617 | CT-Modeller System | Materialise NV | 1997 | — |
| −3 | K033849 | Simplant System | Materialise NV | 2004 | — |
| −2 | K073468 | Mimics | Materialise NV | 2008 | — |
| −1 | K183105 | Mimics Medical | Materialise NV | 2019 | — |
| 0 (this device) | K211966 | Segment 3DPrint | Medviso AB | 2022 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K183105 | Mimics MedicalSummary page 4…Class II – System, Image Processing Regulation Number: 892.2050(Medical image management and processing system) Product Code: LLZ 5.3 Predicate Device Mimics Medical (K183105) Materialise N.V. Technologielaan 15 3001 Leuven Belgium 5.4 Device Description Device Description Segment 3DPrint is a softwar… | 2019 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 29 years and passes through 3 companies; a new generation was cleared every 4.0 years on median.
- None of the 6 ancestors has a recall.
- 16 other devices also cite its predicate K183105.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
Segment 3DPrint is a software for review and segmentation of images from a medical scanner as well as of medical 3D models. Segment 3DPrint is intended to generate 3D models for diagnostic purposes in both paediatric and adult populations in the field of orthopaedic, maxillofacial, and cardiovascular applications. The models can be used for visualisation, measuring, and treatment planning. Output from Segment 3DPrint can be used to fabricate physical replicas, by use of additive manufacturing methods. Segment 3DPrint is intended to be used by medically trained professionals in conjunction with expert clinical judgement.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K211966 · printed Nov 6, 2026
Cite this page
510(k) Report. “K211966: Segment 3DPrint.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K211966
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026