510(k) Report

510(k) · Cleared

Recalled · Class I · 2025

FreeStyle Libre 3 Continuous Glucose Monitoring System

K212132510(k) TraditionalCleared May 26, 2022322-day reviewClass II21 CFR 862.1355Recalls 3 (3 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Abbott Diabetes Care, Inc. · QLG Integrated Continuous Glucose Monitoring System, Factory Calibrated, Not For Use With Automated Insulin Delivery Systems

Cleared on May 26, 2022 as substantially equivalent to K201761 (Abbott Diabetes Care, Inc., 2021) after a 322-day review. Its family tree reaches back 3 generations to 2018. 2 of the 5 devices in its family, counting itself, have a Class I recall. 1 later device descends from it. It has been recalled 3 times, including 3 Class I recalls.

Decided
May 26, 2022
Review
322 days
Class
Class II
Product code
QLG
Recalls
3 (3 Class I)
Predicates
1

Its longest line of descent runs back 3 generations to DEN170088 (2018). 1 later device descends from it, 1 citing it directly. 2 of the 5 devices in this family, counting this one, have a Class I recall.

  1. Root · 3 generations backDEN170088 Dexcom G6 Continuous Glucose Monitoring SystemDexcom, Inc. · 2018
  2. 2 generations backK193371 FreeStyle Libre 2 Flash Glucose Monitoring SystemAbbott Diabetes Care, Inc. · 2020 · Recalled (Class I)
  3. 1 generation backK201761 FreeStyle Libre 2 Flash Glucose Monitoring System (with FreeStyle…Abbott Diabetes Care, Inc. · 2021
  4. This deviceK212132 FreeStyle Libre 3 Continuous Glucose Monitoring SystemAbbott Diabetes Care, Inc. · 2022
  5. Descendant · cites it directly · 0 of its ownK223537 FreeStyle Libre 2 System, FreeStyle Libre 3 SystemAbbott Diabetes Care, Inc. · 2023

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K223537FreeStyle Libre 2 System, FreeStyle Libre 3 SystemAbbott Diabetes Care, Inc. · 2023 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3DEN170088Dexcom G6 Continuous Glucose Monitoring SystemDexcom, Inc.2018—
−2K193371FreeStyle Libre 2 Flash Glucose Monitoring SystemAbbott Diabetes Care, Inc.2020Class I
−1K201761FreeStyle Libre 2 Flash Glucose Monitoring System (with FreeStyle Libre 2 App)Abbott Diabetes Care, Inc.2021—
0 (this device)K212132FreeStyle Libre 3 Continuous Glucose Monitoring SystemAbbott Diabetes Care, Inc.2022—
+1K223537FreeStyle Libre 2 System, FreeStyle Libre 3 SystemAbbott Diabetes Care, Inc.2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
FIG. 1 — Lineage of K212132, 2018–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QLG device

  1. #1 K210943 FreeStyle Libre 2 Flash Glucose Monitoring…score 12.0 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K201761FreeStyle Libre 2 Flash Glucose Monitoring System (with FreeStyle Libre 2 App)
Cleared while this submission was under review
Summary page 4
…Clinical Chemistry Predicate Device Predicate Device: FreeStyle Libre 2 Flash Glucose Monitoring System (with FreeStyle Libre 2 App) (K201761) The predicate device has not been subject to a recall…
Abbott Diabetes Care, Inc.2021—

Also cleared against K201761: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K223537FreeStyle Libre 2 System, FreeStyle Libre 3 SystemAbbott Diabetes Care, Inc.20230

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 24, 2025Class IZ-1023-2026Process controlDue to a manufacturing process issue that may cause carbon build up in the sensor that may result in incorrect low glucose results
Nov 24, 2025Class IZ-1020-2026Process controlDue to a manufacturing process issue that may cause carbon build up in the sensor that may result in incorrect low glucose results
Jul 24, 2024Class IZ-2692-2024Process designUsers of the FreeStyle Libre 3 sensors reported situations where they were receiving erroneously high glucose results. The inaccurate higher glucose values may lead to users calculating higher insulin bolus correctional doses based on…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K193371FreeStyle Libre 2 Flash Glucose Monitoring SystemAbbott Diabetes Care, Inc. · 2020 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 4 years and passes through 2 companies; a new generation was cleared every 1.1 years on median.
  • 1 of the 3 ancestors has a recall of any class; 1 has a Class I recall.
  • Of its descendants, K223537 (Abbott Diabetes Care, Inc., 2023) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K201761.

How does its category compare?

All QLG devices

QLG Integrated Continuous Glucose Monitoring System, Factory Calibrated, Not For Use With Automated Insulin Delivery Systems: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · QLG

2in 2023

2020: 12021: 42022: 22023: 2
2007high 4 (2021) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QLG

259in 2021

2021: 259 days median
2007high 259 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QLG

4in 2025

2023: 12025: 4, 4 Class I
2007high 4 (2025) · low 0 (2007)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · QLG

20,199in 2025

2020: 1,0692021: 22,5002022: 26,5282023: 39,3212024: 35,1082025: 20,199
2007high 39,321 (2023) · low 0 (2007)2025

MAUDE reports naming product code QLG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20201—01,069
20214259022,500
20222—026,528
20232—139,321
20240—035,108
20250—4 (4)20,199
20260—0—

What is it indicated for?

The FreeStyle Libre 3 Continuous Glucose Monitoring System is a real time continuous glucose monitoring (CGM) device with alarms capability indicated for the management of diabetes in persons age 4 and older. It is intended to replace blood glucose testing for diabetes treatment decisions, unless otherwise indicated. The System also detects trends and tracks patterns and aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating…

Read the full statement (126 words)

The FreeStyle Libre 3 Continuous Glucose Monitoring System is a real time continuous glucose monitoring (CGM) device with alarms capability indicated for the management of diabetes in persons age 4 and older. It is intended to replace blood glucose testing for diabetes treatment decisions, unless otherwise indicated.

The System also detects trends and tracks patterns and aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments. Interpretation of the System readings should be based on the glucose trends and several sequential readings over time.

The System is also intended to autonomously communicate with digitally connected devices. The System can be used alone or in conjunction with these digitally connected devices where the user manually controls actions for therapy decisions.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K212132: FreeStyle Libre 3 Continuous Glucose Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K212132

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026