510(k) Report

510(k) · Cleared

Cleared

Dry DBM- A Putty

K212135510(k) TraditionalCleared Oct 4, 202188-day reviewClass II21 CFR 888.3045

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Seaspine Corporation · MQV Filler, Bone Void, Calcium Compound

Cleared on Oct 4, 2021 as substantially equivalent to K091193 (Isotis Orthobiologics, Inc., 2009) after an 88-day review. Its family tree reaches back 4 generations to 2004. 1 later device descends from it.

Decided
Oct 4, 2021
Review
88 days
Class
Class II
Product code
MQV
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K040980 (2004). 9 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 4 generations backK040980 Allomatrix C Putty, Allomatrix Custom Putty, Allomatrix DR Putty…Wrightmedicaltechnologyinc · 2004
  2. 3 generations backK040419 Dynagraft IIIsotis Orthobiologics, Inc. · 2005
  3. 2 generations backK050642 Orthoblast II Putty and PasteIsotis Orthobiologics, Inc. · 2005
  4. 1 generation backK091193 Accell EVO3CIsotis Orthobiologics, Inc. · 2009 · Recalled
  5. This deviceK212135 Dry DBM- A PuttySeaspine Corporation · 2021
  6. Descendant · cites it directly · 0 of its ownK231030 Cove Putty, OsteoCove PuttySeaSpine Orthopedics Corporation · 2023

Most influential descendants

Showing 1 of 1 · See all
  • K231030Cove Putty, OsteoCove PuttySeaSpine Orthopedics Corporation · 2023 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K040980Allomatrix C Putty, Allomatrix Custom Putty, Allomatrix DR Putty, Ignite…Wrightmedicaltechnologyinc2004—
−3K040419Dynagraft IIIsotis Orthobiologics, Inc.2005—
−2K050642Orthoblast II Putty and PasteIsotis Orthobiologics, Inc.2005—
−1K091193Accell EVO3CIsotis Orthobiologics, Inc.20091
0 (this device)K212135Dry DBM- A PuttySeaspine Corporation2021—
+1K231030Cove Putty, OsteoCove PuttySeaSpine Orthopedics Corporation2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200530
200720

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
FIG. 1 — Lineage of K212135, 2004–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQV device

  1. #1 K232315 Catalyst Bone Void Fillerscore 25.2 · 25 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K091193Accell EVO3C
Summary page 4
…3c 510(k) Number Product Code Trade Name Manufacturer PRIMARY PREDICATE Device K091193 MQV, MBP Accell Evo3c IsoTis OrthoBiologics, Inc.* *IsoTis OrthoBiologics, In…
Isotis Orthobiologics, Inc.20091

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K231030Cove Putty, OsteoCove PuttySeaSpine Orthopedics Corporation20230

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 3.7 years on median.
  • 4 of the 9 ancestors have a recall of any class.
  • Of its descendants, K231030 (SeaSpine Orthopedics Corporation, 2023) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MQV devices

MQV Filler, Bone Void, Calcium Compound: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · MQV

14in 2025

2007: 352008: 322009: 232010: 172011: 162012: 92013: 122014: 202015: 182016: 82017: 172018: 232019: 132020: 152021: 82022: 92023: 212024: 282025: 142026 (partial year): 5
2007high 35 (2007) · low 8 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQV

57in 2025

2007: 144 days median2008: 102 days median2009: 180 days median2010: 147 days median2011: 92 days median2012: 107 days median2013: 197 days median2014: 153 days median2015: 184 days median2016: 214 days median2017: 124 days median2018: 124 days median2019: 90 days median2020: 132 days median2021: 88 days median2022: 118 days median2023: 74 days median2024: 55 days median2025: 57 days median2026 (partial year): 96 days median
2007high 214 (2016) · low 55 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQV

1in 2025

2007: 52008: 32009: 12011: 62012: 32013: 22016: 12017: 12018: 22020: 12023: 32024: 22025: 12026 (partial year): 4
2007high 6 (2011) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQV

57in 2025

2007: 672008: 712009: 812010: 682011: 1142012: 1492013: 2232014: 1112015: 1252016: 1062017: 1072018: 862019: 652020: 1262021: 1012022: 472023: 1202024: 682025: 57
2007high 223 (2013) · low 47 (2022)2025

MAUDE reports naming product code MQV, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735144567
200832102371
200923180181
201017147068
201116926114
201291073149
2013121972223
2014201530111
2015181840125
201682141106
2017171241107
201823124286
20191390065
2020151321126
20218880101
20229118047
202321743120
20242855268
20251457157
20265964—

What is it indicated for?

Dry DBM-A Putty is intended to fill voids and gaps in the skeletal system that are not intrinsic to the stability of the bony structure. The product is indicated for use with autograft as a bone graft extender in the posterolateral spine and pelvis. The voids or gaps may be surgically created defects or the result of traumatic injury to the bone

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K212135: Dry DBM- A Putty.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K212135

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026