# K212161: Radical-7 Pulse CO-Oximeter and Accessories, Rad-97 and Accessories

- Pathway: 510(k) (Traditional)
- Applicant: Masimo Corporation
- Decided: Mar 6, 2023 after 602 days
- Product code: MWI (Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms))
- Device class: 2
- Regulation: 21 CFR 870.2300
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 23 generations back to K962603 (1997). 96 ancestors in all.
No later device cites it as a predicate yet.
2 of 97 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K193626: Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Corporation (2020) Summary page 6.
- K193242: Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Radical-7 Pulse CO-Oximeter and Accessories, Masimo Radius-7 Pulse CO-Oximeter and Accessories, Masimo Corporation (2020) Summary page 7.

## Indications for use
The Rad-97 and Accessories is a multi-parameter patient monitor that is intended for multi-parameter physiological patient monitoring in hospital, hospital type facilities, mobile and home environments. The Rad-97 and Accessories can communicate with network systems for supplemental remote viewing and alarming (e.g., at a central station). The Rad-97 and Accessories are indicated for the non-invasive spot-checking and continuous monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) of adult, pediatric, and neonatal patients during both no motion and motion conditions, and for patients who are well or poorly perfused. The Rad-97 and Accessories are indicated for the non-invasive continuous monitoring of carboxyhemoglobin saturation (SpCO) of adult, pediatric, and infant patients during no motion conditions. The Rad-97 and Accessories are indicated for the non-invasive continuous monitoring of methemoglobin saturation (SpMet) of adult, pediatric, and neonatal patients during no motion conditions. The Rad-97 and Accessories are indicated for the non-invasive continuous monitoring of total hemoglobin concentration (SpHD) of adult and pediatric patients during no motion conditions. The Rad-97 and Accessories are indicated for the continuous monitoring of respiratory rate (RRa) for adult, pediatric, and neonatal patients during no motion conditions. In addition, the Rad-97 and Accessories are indicated to provide the non-invasive spot-checking and continuous monitoring data obtained from the Rad-97 and Accessories for functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) to multi-parameter devices for the display on those devices. The Rad-97 and Accessories are not intended to be used as the sole basis for making diagnosis or treatment decisions related to suspected carbon monoxide poisoning; it is intended to be used in conjunction with additional methods of assessing clinical signs and symptoms. The optional NomoLine Capnography product family is intended to be connected to other medical backboard devices for monitoring of breath rate and CO2. The NomoLine Capnography product family is intended to be connected to a patient breathing circuit for monitoring of inspired/expired gases during anesthesia, recovery and respiratory care. The environment is the operating suite, intensive care unit and patient room. The intended patient population is adult, pediatric and infant patients. The optional non-invasive blood pressure (NiBP) module is indicated for the noninvasive measurement of arterial blood pressure. The NiBP module is designed to measure blood pressure for patient population described in the following table: Patient Population Approximate Age Range Newborn (neonate) Birth to 1 month of age Infant 1 month to 2 years of age Child 2 to 12 years of age Adolescent 12-21 years of age Adult 21 years of age and older Devices with Masimo technology are only to be used with Masimo sensors and cables. The Rad-97 and accessories are indicated for the non-invasive continuous monitoring of PVi as a measure of relative variability of the photoplethysmograph (pleth) of adults during no motion conditions. PVimay be used as a noninvasive dynamic indicator of fluid responsiveness in select populations of mechanically ventilated adult patients. Accuracy of PVi in predicting fluid responsiveness is variable and influenced by numerous patient, procedure and device related factors. PVi measures the variation in the plethysmography amplitude but does not provide measurements of stroke volume or cardiac output. Fluid management decisions should be based on a complete assessment of the patient’s condition and should not be based solely on PVi. The Rad-97 and Accessories are indicated for the non-invasive continuous monitoring of respiratory rate from Pleth (RRp) for adult and pediatric patients during no motion conditions. The Radical-7 and Accessories are indicated for the non-invasive spot-checking and continuous monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) of adult, pediatric, and neonatal patients during both no motion and motion conditions, and for patients who are well or poorly perfused in hospitals, hospital-type facilities, mobile, and home environments. The Radical-7 and Accessories are indicated for the non-invasive continuous monitoring of carboxyhemoglobin saturation (SpCO) of adult, pediatric, and infant patients during no motion conditions in hospitals and hospital-type facilities. The Radical-7 and Accessories are not intended to be used as the sole basis for making diagnosis or treatment decisions related to suspected carbon monoxide poisoning; it is intended to be used in conjunction with additional methods of assessing clinical signs and symptoms. The Radical-7 and Accessories are indicated for the non-invasive continuous monitoring of methemoglobin saturation (SpMet) of adult, pediatric, and neonatal patients during no motion conditions in hospitals and hospital-type facilities. The Radical-7 and Accessories are indicated for the non-invasive continuous monitoring of total hemoglobin concentration (SpHb) of adult and pediatric patients during no motion conditions in hospitals and hospital-type facilities. The Radical-7 and Accessories are indicated for the non-invasive continuous monitoring of respiratory rate (RRa) for adult, pediatric, and neonatal patients during no motion conditions in hospitals, hospital-type facilities, home environments, and transport within healthcare facilities. The Radical-7 and Accessories are indicated for the non-invasive continuous monitoring of Respiratory Rate from photoplethysmogram (RRp) for adult and pediatric patients during no motion conditions in hospitals, hospital-type facilities, home environments, and transport within healthcare facilities.

Source page: https://510kreport.com/device/K212161
Methodology: https://510kreport.com/methodology