510(k) · Cleared
ClearedElectronic Blood Pressure Monitor
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Dongguan Kangweile Electronic Technology Co., Ltd. · DXN System, Measurement, Blood-Pressure, Non-Invasive
Cleared on Nov 1, 2021 after a 112-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Nov 1, 2021
- Review
- 112 days
- Class
- Class II
- Product code
- DXN
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DXN device
- #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All DXN devicesDXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · DXN
28in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DXN
142in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DXN
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DXN
239in 2025
MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 27 | 118 | 0 | 21 |
| 2008 | 23 | 82 | 1 | 8 |
| 2009 | 46 | 73 | 3 | 17 |
| 2010 | 43 | 94 | 0 | 14 |
| 2011 | 34 | 72 | 1 | 10 |
| 2012 | 36 | 116 | 0 | 19 |
| 2013 | 34 | 150 | 1 | 72 |
| 2014 | 29 | 133 | 0 | 47 |
| 2015 | 30 | 97 | 0 | 62 |
| 2016 | 30 | 144 | 1 | 54 |
| 2017 | 33 | 184 | 0 | 90 |
| 2018 | 22 | 235 | 0 | 617 |
| 2019 | 33 | 156 | 1 | 96 |
| 2020 | 24 | 198 | 0 | 130 |
| 2021 | 23 | 190 | 0 | 162 |
| 2022 | 25 | 137 | 0 | 155 |
| 2023 | 35 | 182 | 0 | 162 |
| 2024 | 17 | 107 | 3 | 270 |
| 2025 | 28 | 142 | 0 | 239 |
| 2026 | 29 | 147 | 0 | — |
What is it indicated for?
The Electronic Blood Pressure Monitor is non-invasive blood measurement of arterial blood pressure values in adults. It is intended to measure the diastolic, systolic blood pressures and pulse rate through an inflatable cuff wrapped around the wrist. It can be used by medical professionals or at home. The cuff circumference is limited to 13.5-19.5 cm.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K212171 · printed Nov 4, 2026
Cite this page
510(k) Report. “K212171: Electronic Blood Pressure Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K212171
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026