510(k) Report

510(k) · Cleared

Cleared

Jot Dx Insertable Cardiac Monitor

K212206510(k) SpecialCleared Aug 13, 202129-day reviewClass II21 CFR 870.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Abbott (St. Jude Medical) · MXC Recorder, Event, Implantable Cardiac, (Without Arrhythmia Detection)

Cleared on Aug 13, 2021 as substantially equivalent to K202888 (Abbott (St. Jude Medical), 2020) after a 29-day review. Its family tree reaches back 4 generations to 2019. 3 later devices descend from it.

Decided
Aug 13, 2021
Review
29 days
Class
Class II
Product code
MXC
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K190295 (2019). 3 later devices descend from it, 1 citing it directly.

  1. Root · 4 generations backK190295 Confirm Rx Insertable Cardiac MonitorAbbott (St. Jude Medical) · 2019
  2. 3 generations backK192593 Confirm Rx Insertable Cardiac MonitorAbbott · 2019
  3. 2 generations backK193310 myMerlin Mobile Application (Android), myMerlin Mobile Application…Abbott (St. Jude Medical) · 2020
  4. 1 generation backK202888 Confirm Rx Insertable Cardiac MonitorAbbott (St. Jude Medical) · 2020
  5. This deviceK212206 Jot Dx Insertable Cardiac MonitorAbbott (St. Jude Medical) · 2021
  6. Descendant · cites it directly · 2 of its ownK230286 Assert-IQ™ Insertable Cardiac MonitorAbbott Medical · 2023
  7. Descendant · 2 generations on · 1 of its ownK251221 Assert-IQ (DM5000); Assert-IQ (DM5300); Assert-IQ (DM5500)…Abbott · 2025
  8. Descendant · 3 generations on · 0 of its ownK253516 Assert-IQ (DM5100)Abbott Medical · 2025

Most influential descendants

Showing 3 of 3 · See all
  • K230286Assert-IQ™ Insertable Cardiac MonitorAbbott Medical · 2023 · cites it directly2descendants
  • K251221Assert-IQ (DM5000); Assert-IQ (DM5300); Assert-IQ (DM5500); Merlin.net (MN7000)Abbott · 2025 · 2 generations on1descendant
  • K253516Assert-IQ (DM5100)Abbott Medical · 2025 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K190295Confirm Rx Insertable Cardiac MonitorAbbott (St. Jude Medical)2019—
−3K192593Confirm Rx Insertable Cardiac MonitorAbbott2019—
−2K193310myMerlin Mobile Application (Android), myMerlin Mobile Application (iOS)Abbott (St. Jude Medical)2020—
−1K202888Confirm Rx Insertable Cardiac MonitorAbbott (St. Jude Medical)2020—
0 (this device)K212206Jot Dx Insertable Cardiac MonitorAbbott (St. Jude Medical)2021—
+1K230286Assert-IQ™ Insertable Cardiac MonitorAbbott Medical2023—
+2K251221Assert-IQ (DM5000); Assert-IQ (DM5300); Assert-IQ (DM5500); Merlin.net (MN7000)Abbott2025—
+3K253516Assert-IQ (DM5100)Abbott Medical2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202520
FIG. 1 — Lineage of K212206, 2019–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MXC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MXC device

  1. #1 K230286 Assert-IQ™ Insertable Cardiac Monitorscore 9.5 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K202888Confirm Rx Insertable Cardiac Monitor
Summary page 4
…Jot Dx™ Insertable Cardiac Monitor has not been specifically tested in pediatric patients. LEGALLY MARKETED DEVICES TO WHICH SUBSTANTIAL EQUIVALENCE IS CLAIMED 510(k) K202888: INDICATIONS FOR USE Confirm Rx™ Insertable Cardiac Monitor System The are no changes to the Indications for Use as a result o…
Abbott (St. Jude Medical)2020—

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K230286Assert-IQ™ Insertable Cardiac MonitorAbbott Medical20232

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 2 years and passes through 2 companies; a new generation was cleared every 8 months on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K230286 (Abbott Medical, 2023) has gone furthest, with 2 descendants of its own.

How does its category compare?

All MXC devices

MXC Recorder, Event, Implantable Cardiac, (Without Arrhythmia Detection): FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · MXC

1in 2023

2007: 22008: 12009: 22010: 12012: 22014: 12017: 22019: 32020: 32021: 12023: 1
2007high 3 (2019) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MXC

64in 2020

2019: 58 days median2020: 64 days median
2007high 64 (2020) · low 58 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MXC

1in 2018

2011: 12018: 1
2007high 1 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MXC

1,105in 2025

2008: 32009: 122010: 142011: 212012: 302013: 1442014: 5982015: 2352016: 1942017: 2262018: 1,8192019: 1,5932020: 1,1002021: 8322022: 6282023: 8282024: 9752025: 1,105
2007high 1,819 (2018) · low 0 (2007)2025

MAUDE reports naming product code MXC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—03
20092—012
20101—014
20110—121
20122—030
20130—0144
20141—0598
20150—0235
20160—0194
20172—0226
20180—11,819
201935801,593
202036401,100
20211—0832
20220—0628
20231—0828
20240—0975
20250—01,105
20260—0—

What is it indicated for?

The Jot Dx™ ICM is indicated for the monitoring and diagnostic evaluation of patients who experience unexplained symptoms such as: dizziness, palpitations, chest pain, syncope, and shortness of breath, as well as patients who are at risk for cardiac arrhythmias. It is also indicated for patients who have been previously diagnosed with atrial fibrillation or who are susceptible to developing atrial fibrillation.

The Jot Dx™ ICM has not been specifically tested for pediatric use.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K212206: Jot Dx Insertable Cardiac Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K212206

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026