510(k) Report

510(k) · Cleared

Cleared

Luna G3 BPAP System

K212263510(k) TraditionalCleared Mar 25, 2022248-day reviewClass II21 CFR 868.5905

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

3B Medical, Inc. · BZD Ventilator, Non-Continuous (Respirator)

Cleared on Mar 25, 2022 as substantially equivalent to K201620 (3B Medical, Inc., 2021) after a 248-day review. Its family tree reaches back 12 generations to 1996. 3 of the 37 devices in its family, counting itself, have a Class I recall.

Decided
Mar 25, 2022
Review
248 days
Class
Class II
Product code
BZD
Recalls
None
Predicates
1

Its longest line of descent runs back 12 generations to K953930 (1996). 36 ancestors in all, the oldest K930656 (1994). No later device cites it as a predicate yet. 3 of the 37 devices in this family, counting this one, have a Class I recall.

  1. Root · 12 generations backK953930 Virtuoso Smart Cpap SystemRespironics, Inc. · 1996
  2. 8 generations between
  3. 3 generations backK113068 Remstar Auto a-Flex HTRespironics, Inc. · 2011 · Recalled (Class I)
  4. 2 generations backK131982 Remstar Auto a-Flex HTRespironics, Inc. · 2013 · Recalled (Class I)
  5. 1 generation backK201620 Luna® G3 BPAP 25A3B Medical, Inc. · 2021
  6. This deviceK212263 Luna G3 BPAP System3B Medical, Inc. · 2022
Show all 12 generations
  1. Root · 12 generations backK953930 Virtuoso Smart Cpap SystemRespironics, Inc. · 1996
  2. 11 generations backK993433 Virtuoso LX Smart Cpap SystemRespironics, Inc. · 1999
  3. 10 generations backK012554 Remstar Auto Cpap SystemRespironics, Inc. · 2002
  4. 9 generations backK031460 Modification to Remstar Auto Cpap SystemRespironics, Inc. · 2003
  5. 8 generations backK032834 Bipap Pro 2 BI-Level SystemRespironics, Inc. · 2004
  6. 7 generations backK043607 Bipap Pro 2 BI-Level System with BI-FlexRespironics, Inc. · 2005
  7. 6 generations backK050759 Bipap AutoRespironics, Inc. · 2005 · Recalled
  8. 5 generations backK063830 Remstar Aflex Cpap SystemRespironics Inc., Sleep & Home Respiratory Group · 2007
  9. 4 generations backK091319 Remstar Auto a-FlexRespironics Inc., Sleep & Home Respiratory Group · 2009 · Recalled (Class I)
  10. 3 generations backK113068 Remstar Auto a-Flex HTRespironics, Inc. · 2011 · Recalled (Class I)
  11. 2 generations backK131982 Remstar Auto a-Flex HTRespironics, Inc. · 2013 · Recalled (Class I)
  12. 1 generation backK201620 Luna® G3 BPAP 25A3B Medical, Inc. · 2021
  13. This deviceK212263 Luna G3 BPAP System3B Medical, Inc. · 2022

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K953930Virtuoso Smart Cpap SystemRespironics, Inc.1996—
−11K993433Virtuoso LX Smart Cpap SystemRespironics, Inc.1999—
−10K012554Remstar Auto Cpap SystemRespironics, Inc.2002—
−9K031460Modification to Remstar Auto Cpap SystemRespironics, Inc.2003—
−8K032834Bipap Pro 2 BI-Level SystemRespironics, Inc.2004—
−7K043607Bipap Pro 2 BI-Level System with BI-FlexRespironics, Inc.2005—
−6K050759Bipap AutoRespironics, Inc.20051
−5K063830Remstar Aflex Cpap SystemRespironics Inc., Sleep & Home Respiratory Group2007—
−4K091319Remstar Auto a-FlexRespironics Inc., Sleep & Home Respiratory Group2009Class I
−3K113068Remstar Auto a-Flex HTRespironics, Inc.2011Class I
−2K131982Remstar Auto a-Flex HTRespironics, Inc.2013Class I
−1K201620Luna® G3 BPAP 25A3B Medical, Inc.2021—
0 (this device)K212263Luna G3 BPAP System3B Medical, Inc.2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199610
199720
199820
200020
200130
200230
200330
200430
200510
201210
201310
201410
FIG. 1 — Lineage of K212263, 1996–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZD device

  1. #1 K250624 myAirscore 15.7 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K201620Luna® G3 BPAP 25A
Summary page 4
…Products Code BZD Medical Specialties Anesthesiology Predicate Device Luna G3 BPAP 25A (K201620) Reference Device Juno VPAP ST-A (K153061) 1 === Pa…
3B Medical, Inc.2021—
†K153061Juno VPAP ST-AResmed, Ltd.2016—

Also cleared against K201620: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K131982Remstar Auto a-Flex HTRespironics, Inc. · 2013 · 2 generations back · ◆ on the line of descent in FIG. 15 Class I recalls
  • K113068Remstar Auto a-Flex HTRespironics, Inc. · 2011 · 3 generations back · ◆ on the line of descent in FIG. 12 Class I recalls
  • K091319Remstar Auto a-FlexRespironics Inc., Sleep & Home Respiratory Group · 2009 · 4 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 26 years and passes through 3 companies; a new generation was cleared every 1.8 years on median.
  • 12 of the 36 ancestors have a recall of any class; 3 have a Class I recall.
  • 1 other device also cites its predicate K201620.

How does its category compare?

All BZD devices

BZD Ventilator, Non-Continuous (Respirator): FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · BZD

7in 2025

2007: 212008: 172009: 232010: 122011: 232012: 212013: 232014: 142015: 112016: 122017: 52018: 52019: 62020: 62021: 62022: 42023: 52024: 102025: 72026 (partial year): 10
2007high 23 (2009) · low 4 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZD

189in 2025

2007: 83 days median2008: 108 days median2009: 90 days median2010: 122 days median2011: 125 days median2012: 133 days median2013: 127 days median2014: 172 days median2015: 224 days median2016: 217 days median2017: 221 days median2018: 280 days median2019: 231 days median2020: 137 days median2021: 192 days median2022: 253 days median2023: 204 days median2024: 132 days median2025: 189 days median2026 (partial year): 214 days median
2007high 280 (2018) · low 83 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZD

8in 2023

2007: 292008: 22009: 12011: 12019: 4, 4 Class I2023: 8, 7 Class I2026 (partial year): 2, 2 Class I
2007high 29 (2007) · low 0 (2010)2026

Class I (13 since 2007) Class II/III not classified

Adverse event reports per year · BZD

60,279in 2025

2007: 652008: 672009: 1472010: 1432011: 1892012: 1392013: 822014: 862015: 1142016: 1182017: 1482018: 1012019: 1882020: 1262021: 6,0662022: 90,7682023: 27,9872024: 68,2622025: 60,279
2007high 90,768 (2022) · low 65 (2007)2025

MAUDE reports naming product code BZD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200721832965
200817108267
200923901147
2010121220143
2011231251189
2012211330139
201323127082
201414172086
2015112240114
2016122170118
201752210148
201852800101
201962314 (4)188
202061370126
2021619206,066
20224253090,768
202352048 (7)27,987
202410132068,262
20257189060,279
2026102142 (2)—

What is it indicated for?

The Luna® G3 BPAP System is a Bi-level PAP (Bi-level Positive Airway Pressure) device designed for the treatment of adult Obstructive Sleep Apnea (OSA). The integrated humidifier is indicated for the humidification and warming of air from the flow generator device. These devices are intended for single-patient use by prescription in the home or hospital/institutional environment on adult patients. It is to be used on patients > 66 lbs / 30 kg for whom CPAP therapy has been prescribed.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K212263: Luna G3 BPAP System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K212263

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026